Page 13  — English

OPERATION

OXyGENATED FUELS

DO  NOT  USE  E85  FUEL.  IT  WILL  VOID  yOUR  WAR-
RANTy.
NOTE:

 Fuel system damage or performance problems re-

sulting from the use of an oxygenated fuel containing more 
than the percentages of oxygenates stated below 

are not 

covered under warranty.
Ethanol.

 Gasoline containing up to 10% ethanol by volume 

(commonly referred to as E10) or 15% ethanol by volume 
(commonly referred to as E15) are acceptable. E85 is not.

CAUTION:

On a level surface with the engine off, check the lubricant 
level before each use of the generator. 

STARTING THE ENGINE

See Figures 9 - 11.

NOTE:

  If location of generator is not level, the unit may not 

start or may shut down during operation.

 

Unplug all loads from the generator.

 

Turn the fuel valve to the ON position.

 

Move the choke lever right to the START position.

 

NOTE: 

If  engine  is  warm  or  the  temperature  is  above 

50˚F, move the choke lever left to the RUN position.

 

Put the engine switch in the ON ( I ) position.

 

Pull the recoil starting grip until the engine runs (a maxi-
mum of 6 times).

 

NOTE:

  Do not allow the grip to snap back after starting; 

return it gently to its original place.

 

Allow the engine to run for 15 seconds, then move the 
choke lever left to the RUN position.

STOPPING THE ENGINE

See Figures 9 - 10.

To stop the engine under normal operating conditions:

 

Remove any load from the generator.

 

Turn the fuel valve to the OFF position.

 

Put the engine switch in the OFF ( O ) position.

To stop the engine in an emergency situation:

 

Put the engine switch in the OFF ( O ) position.

NOTE:

  Non-detergent  or  2-stroke  engine  lubricants  will 

damage the engine and should not be used. 

 

Unscrew the oil cap/dipstick and remove.

 

Wipe  dipstick  clean  and  re-seat  in  hole;  do  not  re-
thread.

 

Remove dipstick again and check lubricant level. Lubri-
cant level should fall between the hatched areas on the 
dipstick.

 

If level is low, add engine lubricant until the fluid level rises 
to the upper portion of the dipstick. 

 

Replace and secure the oil cap/dipstick.

CHECkING/ADDING FUEL 

See Figure 8.

 

Remove the fuel cap.

 

Fill the fuel tank to 1 in. below the top of the fuel neck.

 

Replace and secure the fuel cap.

NOTE:

  Always use unleaded gasoline with a pump octane 

rating of 86 or higher. Never use old, stale, or contaminated 
gasoline, and do not use an oil/gas mixture. Do not allow dirt 
or water into the fuel tank. 

Do not use E85 fuel.

USING FUEL STABILIzER 

Fuel gets old, oxidizes, and breaks down over time. Adding 
a fuel stabilizer (not included) extends the usable life of fuel 
and helps prevent deposits from forming that can clog the 
fuel system. Follow fuel stabilizer manufacturer’s directions 
for correct ratio of stabilizer to fuel.

 

Add stabilizer to fuel tank, then fill with gasoline following 
previous instructions.

 

NOTE: 

Fuel stabilizer and gasoline can be mixed prior 

to filling the tank by using a gas can or other approved 
fuel container and shaking gently to combine.

 

Replace and secure the fuel tank cap.

 

Start and run the engine for at least 5 minutes to allow 
stabilizer to treat the entire fuel system.

Содержание HU5000 Series

Страница 1: ...o generador ha sido diseñado y fabricado de conformidad con estrictas normas para brindar fiabilidad facilidad de uso y seguridad para el operador Con el debido cuidado le brindará muchos años de sólido y eficiente funcionamiento PELIGRO El incumplimiento de las instrucciones en este manual del operador puede CAUSARLE LA MUERTE O LESIONARLE GRAVEMENTE Le agradecemos su compra SAVE THIS MANUAL FOR ...

Страница 2: ...i See this fold out section for all of the figures referenced in the operator s manual Consulte esta sección desplegable para ver todas las figuras a las que se hace referencia en el manual del operador ...

Страница 3: ...inal terminal de conexión a tierra K Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite L Oil drainage bolt perno de drenaje de aceite H 7 4 8 6 5 9 3 2 1 10 j A Bolt perno B Frame armazón C Frame support with foot soporte del armazón con pie D Flat washer arandela plana E Lock washer arandela de seguridad F Nut tuerca Fig 4 A Axle eje B Wheel rueda C Frame armazón D Flat washer...

Страница 4: ... Off apagado C On encendido Fig 14 A move choke lever left to run desplace izquierda la palanca del anegador para poner en marcha B move choke lever right to start desplace derecha de la palanca del anegador para arrancar Fig 15 A Air filter cover tapa del filtro de aire B Latches pestillos C Filter element elemento de filtro D Air filter unit unidad del filtro de aire A Oil drainage bolt perno de...

Страница 5: ...ombustible B Fuel valve válvula de combustible C Petcock llave de purga D Off apagado E On encendido A Fuel line conducto de combustible B Fuel filter filtro de combustible A Carburetor drain screw tornillo de drenaje del carburador A b C D E A A B A ...

Страница 6: ...urely to a suitable ground source The National Electric Code contains several practical ways in which to establish a good ground source If a steel or iron rod is used it should be at least 5 8 in diameter and if a nonferrous rod is used it should be at least 1 2 in diameter and be listed as material for grounding Drive the rod or pipe to a depth of 8 ft If a rock bottom is encountered less than 4 ...

Страница 7: ...umes will kill you Always wear eye protection with side shields marked to comply with ANSI Z87 1 as well as hearing protection when operating this equipment Keep all bystanders children and pets at least 10 feet away Wear sturdy and dry shoes or boots Do not operate while barefoot Do not operate generator when you are tired or under the influence of drugs alcohol or medication Keep all parts of yo...

Страница 8: ...gas tank to overflow when filling Fill to 1 in below the top neck of the gasoline tank to allow for fuel expansion Do not cover the fuel tank cap when the engine is running Covering the fuel tank cap during use may cause engine failure and or damage to the tool Do not smoke when filling the generator with gasoline Shutdowntheengineandallowtocoolcompletelybefore adding gasoline or lubricant to the ...

Страница 9: ...plosive Fire or explosion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of serious injury avoid attempting to lift the generator alone Ground Consult with local electrician to determine grounding requirements before operation Electrocution Failure to properly ground generator can result in ele...

Страница 10: ...nd vents SYMBOLS Some of the following symbols may be used on this product Please study them and learn their meaning Proper interpretation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per second W Watt Power hrs Hours Time gal Gallon Volume qt Quart Volume DANGER DANGER PELIGR...

Страница 11: ...arth ground Hot SURFACE warning Do not touch the muffler or aluminum cylinder of the en gine They are very HOT and will cause severe burns Don t putanyflammableor combustible materi als in the direct path of the exhaust SYMBOLS extension cord cable size Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load Inadequate size cables ...

Страница 12: ... the generator if solid state equipment such as a television set is used A power line conditioner is recommended for some solid state applications electrical generator Capacity Make sure the generator can supply enough continuous run ning and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the c...

Страница 13: ...e loads than the generator capacity Take special care to consider surge loads in generator capacity as previously described CAUTION Do not overload the generator s capacity Exceeding the generator s wattage amperage capacity can damage the generator and or electrical devices connected to it Application Equipment Estimated Run Watts Estimated Starting Watts Emergency Home Standby Clock Radio 50 50 ...

Страница 14: ...unt of dirt and dust drawn into the unit during operation choke lever The choke lever is used when starting the engine engine switch The engine switch is used in combination with the recoil starter grip to start the generator It is also used to turn the generator off fuel tank The fuel tank has a capacity of 6 gallons fuel valve The flow of fuel through the generator is controlled by the position ...

Страница 15: ...ance WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leadi...

Страница 16: ...danger Failure to properly ground generator can result in elec trocution especially if the generator is equipped with a wheel kit National Electric Code requires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements warning Do not attempt to lift the unit by the handle assembly If it is necessary to lift the generator always grasp by the...

Страница 17: ... the OFF O position To stop the engine in an emergency situation Put the engine switch in the OFF O position NOTE Non detergent or 2 stroke engine lubricants will damage the engine and should not be used Unscrew the oil cap dipstick and remove Wipe dipstick clean and re seat in hole do not re thread Remove dipstick again and check lubricant level Lubri cant level should fall between the hatched ar...

Страница 18: ... in the air filter unit Replace the air filter cover and latch to secure NOTE Do not run the generator without the air filter Rapid engine wear will result changing engine lubricant See Figure 13 Remove the oil cap dipstick Place a container underneath the oil drainage bolt to collect used lubricant as it drains Unscrew the oil drainage bolt and remove Allow lubricant to drain completely Reinstall...

Страница 19: ...er end in a fuel container large enough to catch the fuel being drained from the tank Turn the fuel valve to the ON position When the fuel has drained from the tank close the fuel valve and reinstall fuel line securely on fuel valve maintenance draining the carburetor Turn the engine switch off O Turn the fuel valve to the OFF position Position a suitable container under the carburetor drain screw...

Страница 20: ...rope to distribute the oil Reinstall spark plug Change engine lubricant After removal from storage Fill with fresh gasoline MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Every 6 months or 100 hours of operation Every year or after 300 hours of operation Check Engine Lubricant Change Engine Lubricant Check Air Filter Clean Air ...

Страница 21: ...ker is off Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise Anoccasionallight knocking or ping ing under heavy load is not a cause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of gasoline be ing used Switch to a different brand of gaso...

Страница 22: ...t alteration modification the effects of corrosion erosion normal wear and tear or repairs by other than the Company or its authorized service representative Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instruc tions and recommendations of the Company as set forth in the Product s operator s manual or if the Product is used as rental e...

Страница 23: ...ded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds Dirt or grit related wear caused by improper air cleaner maintenance most often resulting in worn piston piston rings cylinders valves valve guides carburetor or other internal components Broken or scored parts caused by low lubricant level dirty or improper grade of lubricant Engine tune ups and norma...

Страница 24: ...22 English NOTES ...

Страница 25: ...22 English NOTES ...

Страница 26: ...s maneras prácticas para establecer una buena fuente de conexión a tierra Si se utiliza una barra de acero o de hierro éste debe ser de 15 9 mm 5 8 pulg de diámetro y si se utiliza una barra no ferrosa ésta debe ser de 13 mm 1 2 pulg de diámetro como mínimo y estar listada como material adecuado para conexión a tierra Hinque la barra o tubo hasta una profundidad de 2 44 m 8 pies Si se encuentra ro...

Страница 27: ...ilice protección ocular con protección lateral con la marca de cumplimiento de la norma ANSI Z87 1 como así también protección auditiva cuando utilice este equipo Mantenga a todos los circunstantes niños y animales por lo menos a 3 m 10 pies de distancia Use botas o zapatos robustos y secos No utilice la unidad estando descalzo No utilice este generador cuando se encuentre fatigado enfermo o bajo ...

Страница 28: ... cubra la tapa del tanque de combustible cuando el motor esté en funcionamiento Al cubrir la tapa del tanque de combustible durante el funcionamiento se puede producir una falla en el motor o un daño a la herramienta No fume mientras abastece de gasolina el generador Apague el motor y déjelo enfriar por completo antes de agregar gasolina o lubricante al generador No retire la varilla de nivel de a...

Страница 29: ...losivos El fuego o una explosión pueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corporales o daños materiales evite tocar toda superficie caliente Peligro al levantar Para reducir el riesgo de lesiones serias evite intentar levantar el generador usted solo Conexión a tierra Consulte a un electricista de la localidad para determinar los re...

Страница 30: ...as puertas y las ventanas abiertas Sólo utilícelo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos SÍMBOLOS Es posible que se empleen en este producto algunos de los siguientes símbolos Le suplicamos estudiarlos y aprender su significado Una correcta interpretación de estos símbolos le permitirá utilizar mejor y de manera más segura el producto SÍMBOLO NOMBRE DENOMINACIÓN EXPLICACIÓN V Vol...

Страница 31: ...ni el cilindro de aluminio del motor Están muy CALIENTES y causan quemadurasgraves No ponga ningún material inflamableocombustible d i r e c t a m e n t e e n la trayectoria de las e m a n a c i o n e s d e l escape SÍMBOLOS Calibre del cordón de extensión Consulte el cuadro mostrado abajo para asegurarse de que el calibre de los cordones de extensión que utilice puedan con la carga eléctrica requ...

Страница 32: ...léctrica para algunas aplicaciones por ejemplo con una computadora También podria resultar necesario un condicionador de la línea eléctrica para algunas aplicaciones de equipo de estado sólido Capacidad del generador Cerciórese que el generador pueda suministrar suficientes vatios de potencia continua en marcha y de sobrecorriente al arrancar para los equipos que desee alimentar al mismo tiempo Si...

Страница 33: ...nga especial cuidado al considerar las cargas de sobrecorriente en la capacidad del generador según se describió anteriormente PRECAUCIÓN No exceda la capacidad del generador Si excede la capacidad de corriente amperios y potencia vatios del generador puede dañar el generador y los dispositivos eléctricos conectados al mismo aspectos eléctricos Herramienta o aparato En marcha en vatios Estimado W ...

Страница 34: ...se emplea al arrancar el motor interruptor del motor El interruptor del motor se utiliza en combinación con el mango del arrancador retráctil para arrancar el generador Además se utiliza para apagar el generador TANQUE DE COMBUSTIBLE El tanque de combustible tiene una capacidad de 22 7 L 6 galones válvula de combustible El flujo de combustible a través del generador se controla por medio de la pos...

Страница 35: ...suplicamos llamar al 1 866 340 3912 donde le brindaremos asistencia ADVERTENCIA Si hay piezas dañadas o faltantes no utilice este producto sin haber reemplazado todas las piezas La inobservancia de esta advertencia podría causar lesiones serias ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cualquier alteración o modificación constituye maltra...

Страница 36: ...sentirse descompuesto mareado o débil luego de que el generador estuvo funcionando trasládese adonde haya aire fresco INMEDIATAMENTE Vea a un doctor Puede sufrir intoxicación por monóxido de carbono Peligro El incumplimiento de conectar correctamente a tierra el generador puede resultar en electrocución especialmente si el generador está equipado con un conjunto de ruedas El Reglamento Nacional de...

Страница 37: ...a mezcla Coloque de nuevo la tapa del tanque de combustible y asegúrela Arranque el motor y déjelo funcionar por lo menos cinco minutos para permitir que el estabilizador trate todo el sistema de combustible COMBUSTIBLES OXIGENADOS NO USE COMBUSTIBLE E85 ANULARÁ SU GARANTÍA NOTA No están cubiertos en la garantía los problemas de desempeño o daños al sistema de combustible producidos por el uso de ...

Страница 38: ...a funcionar el generador sin los filtro de aire Se causa un desgaste acelerado del motor cambio del lubricante del motor Vea la figura 13 Retire la tapa de relleno de aceite varilla medidora de aceite Coloque un recipiente bajo el perno de drenaje de aceite para recoger el lubricant a medida que salga Desenrosque el perno de drenaje de aceite y retírelo Permita que se drene completamente el lubric...

Страница 39: ...jetos pesados LIMPIEZA DEL ORIFICIO DE ESCAPE Y DEL SILENCIADOR Según sea el tipo de combustible empleado el tipo y cantidad de lubricante empleado así como las condiciones de funcionamiento puede obstruirse el orificio de escape y el silenciador con depósitos de carbono Si observa alguna pérdida de potencia en la productos con motor de gasolina quizá sea necesario eliminar dichos depósitos para r...

Страница 40: ... aceite Instale de nuevo la bujía Cambie el lubricante del motor Al sacar la unidad después de haberla tenido guardada Reabastezca de gasolina fresca la unidad PROGRAMA DE MANTENIMIENTO Antes de cada uso Al cabo del primer mes o 20 horas de funcionamiento Cada 3 meses o 50 horas de func ionamiento Cada 6 meses o 100 horas de funcionamiento Cada año o luego de 300 horas de funcionamiento Revisar el...

Страница 41: ...uese con un centro de servicio autorizado No funciona el receptáculo de corriente alterna El disyuntor está en apagado off Está defectuoso el dispositivo conectado Ponga en encendido ON el disyuntor de corriente alterna Pruebe con un dispositivo diferente El generador produce un ruido como de cascabeleo o explosiones Unleveruidoocasionalde cascabeleo o explosiones si la carga es pesada no debe ser...

Страница 42: ...ión los efectos de la corrosión la erosión el desgaste normal o las reparaciones realizadas por personas ajenas a la Compañía o a sus representantes de servicio autorizados La garantía queda anulada si el cliente no instala mantiene o utiliza el producto respetando las instrucciones y las recomendaciones de la Compañía según se expresa en el manual del operador del Producto o si el Producto se uti...

Страница 43: ... aire las aletas de enfriamiento o cubierta de paso de aire Desgaste propio del polvo o la arenilla ocasionado por el mantenimiento inadecuado del filtro de aire que generalmente provoca el desgaste de los pistones los aros del pistón los cilindros las válvulas las guías de las válvulas el carburador u otros componentes internos Piezas rotas o rayadas debido a un bajo nivel de lubricante suciedad ...

Страница 44: ... the space provided below MODEL NO _ _________________________________ SERIAL NO __________________________________ SERVICIO Para obtener piezas o servicio comuníquese con el centro de servicio autorizado de productos más cercano Asegúrese de proporcionar todos los datos pertinentes al llamar o al presentarse personalmente Para obtener información sobre el centro de servicio autorizado más cercano...

Отзывы: