Husky HSK140HD Скачать руководство пользователя страница 4

4

Charging with 12 VOLT DC Adapter

 - Plug the DC fused Recharge Adapter (included)

into the Recharge Port (barrel receptacle) just behind the rubber Bezel and then insert the ciga-

rette lighter plug into the cigarette lighter socket of your vehicle or other 12 VDC power source.

Make sure the Locking Trigger Switch is in the OFF position. Allow approximately 3 hours

charging time if the engine is running.

WARNING:

 Use the supplied DC Recharge Adapter, do not substitute.

1. Move the rubber plug from the Recharge Port. It is there to keep out dust and moisture.

2. Connect the DC Recharge Adapter’s large cigarette lighter type plug to a 12 volt DC source.

3. Plug the adapter’s barrel connecter into the Recharge Port located near the rubber bezel.

4. Recharge for 3 hours maximum.

5. After recharge, disconnect the barrel connector from the Recharge Port and store the adapter.

6. Replace the rubber plug in the Recharge Port.

AC RECHARGE

Make sure that the AC source is 110/120 volts, 60 Hz.

WARNING:

 Use the supplied AC Recharge adapter, do not substitute with any other.

1. Lift the rubber plug from the Recharge Port. (see figure  3) It is there to keep out dust

    and moisture.

2. Connect the AC adapter into wall outlet. (see figure 3)

3. Plug the adapter’s barrel connecter into the Recharge Port.

4. Recharge for 10 hours maximum.

5. After recharge, disconnect the barrel connector from the Recharge Port and store the adapter.

6. Replace the rubber plug in the Recharge Port.

4. PERIODIC MAINTENANCE

All batteries lose charge over time, especially when they are warm. AC recharge is recom-

mended every two months, when not in frequent use. Use the AC recharger and charge for the

recommended time. If the unit gets dirty, gently clean the outer surfaces of the spotlight unit with

a soft cloth moistened with a mild solution of water and detergent.

5. PARTS REPLACEMENT

Three parts are replaceable by users. The quartz halogen bulb and sealed lead acid battery are

proprietary and are available through HUSKY. A substitute 6 volt H3 55 watt bulb may be used

instead of a HUSKY bulb. These can also be purchased from popular automotive parts suppliers

nationwide. The DC charging adapter fuse is replaceable. Contact HUSKY’s Technical Support De-

partment for replacement parts and any additional information that you may need. They may be

reached toll free (800) 916-7004.

DC PLUG FUSE REPLACEMENT

The fuse in the DC plug protects the charging circuit of the DC Recharge Adapter.  This fuse may

blow if the spotlight is operated when the DC Recharge Adapter is powered and the DC cord is

connected to the recharge port. During DC recharge, if there is no slight warming of the DC

plug, you should suspect that 6 volts DC is not powering the plug or the fuse is opened.

To replace the fuse:

1. Unscrew the end cap of the DC Plug. (counterclockwise)

2. Remove spring center contact and fuse.

3. Check fuse with a continuity checker.

4. If blown, locate replacement fuse with same type and rating.

5. Replace the fuse, spring, contact and end cap.

6. Screw end cap clockwise until it is finger tight-DO NOT OVER-TIGHTEN

7. Check for proper operation of DC Charger Adapter.

SPOTLIGHT BULB REPLACEMENT

To replace the H3 type 6 volt bulb, you will need a small Phillips type screwdriver and a replace-

Содержание HSK140HD

Страница 1: ...READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28T...

Страница 2: ...ass and a sealed lead acid battery 9 Dispose of unusable batteries in a responsible manner See battery disposal section 10 Make sure that during recharge all cords are protected from any type of damag...

Страница 3: ...ed from either locked position by pressing on the Handle Lock Button located near two handle screws and rotating the handle to the new position When the handle is close to the body of the light folded...

Страница 4: ...y when they are warm AC recharge is recom mended every two months when not in frequent use Use the AC recharger and charge for the recommended time If the unit gets dirty gently clean the outer surfac...

Страница 5: ...two screws 19 Replace rubber bezel so that Recharge Port Plug can plug into the Recharge Port 20 Operate switch to ensure proper operation of spotlight REPLACING THE BATTERY PACK The sealed lead acid...

Страница 6: ...ly Recycling is required contact your local authority for information Failure to comply with local state and federal regulations can result in fines or imprisonment Battery Disposal Warnings Do not di...

Страница 7: ...ew or reconditioned unit of the same or comparable design The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period The customer is responsible for t...

Страница 8: ...8 2002 HUSKY PROFESSIONAL TOOLS 4140 SW 28 WAY FT LAUDERDALE FL 33312 MADE IN CHINA...

Отзывы: