background image

 17 

HUSKYTOOLS.COM

 

 

Please contact 1-888-43-HUSKY for further assistance.

Operation

Preparing for use

CAUTION:

 Check for proper oil level before operating!

NOTE:

 The pump oil level is full (1) as shown.

NOTE:

 Use SAE 30 industrial grade air compressor oil or 

full synthetic motor oil like Mobil 1® 10W30. 

NOTE:

 Do not use regular automotive oil. Additives in 

regular motor oil can cause valve deposits and reduce pump 
life. 

NOTE:

 For maximum pump life, drain and replace oil after 

the fi rst hour of run time. 

 

Use the sight glass on the pump to determine the oil level.

 

Add oil to the pump if the oil level is low (2).

Starting-up and breaking-in the 
compressor

WARNING:

 Do not attach air tools to the open end of the 

hose until start-up is completed and the unit checks okay.

WARNING:

 Never disconnect threaded joints with 

pressure in the tank!

 

With the power turned off, open the tank drain valve. The 
tank will not readily buildup any pressure.

 

Return power to the air compressor unit (A).

 

Run the air compressor unit (A) for thirty (30) minutes at 
zero (0) psi (under no load) to break-in the pump parts.

 

Shut power off to the air compressor unit (A), and turn the 
tank drain valve to shut off air flow. The air compressor unit 
(A) is now ready for use.

1

2

A

Содержание HS518102

Страница 1: ...enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky USE AND CARE GUIDE 80 GALLON STATIONARY AIR COMPRESSOR Questi...

Страница 2: ...ntly hazardous situation which if not avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CA...

Страница 3: ...he tank resulting in damage from rupture or explosion Always replace worn cracked or damaged tanks CAUTION See the compressor specification decal for maximum operating pressure Do not operate with pre...

Страница 4: ...not recommended for use with this compressor Alterations and or modifications are a form of misuse which could result in a hazardous condition leading to possible personal injury or equipment damage...

Страница 5: ...l and local electrical codes 1 Follow all local electrical and safety codes as well as in the United States the National Electrical Codes NEC and Occupational Safety and Health Act OSHA 2 Avoid body c...

Страница 6: ...or expense that may result from any defect failure or malfunction of the manufacturer s product is not covered by this warranty Some states do not allow the exclusion or limitations of incidental or...

Страница 7: ...inimum clearance of 18 in between the compressor flywheel or fan and the wall and ensure clear access to the drain valve to facilitate condensate drainage Do not locate the compressor air inlet near s...

Страница 8: ...8 Pre Installation PACKAGE CONTENTS Part Description Quantity A Air Compressor Unit 1 B Air Filter Assembly 1 A B...

Страница 9: ...ximum C Discharge Tube This tube carries compressed air from the pump to the check valve This tube becomes very hot during use To avoid the risk of severe burns never touch the discharge tube D Check...

Страница 10: ...utlet Size 3 4 NPT Number of Cylinders 2 Oil Capacity approximately 2 quarts Voltage 230 240 Volts 22 Amps Length 27 in 60 Hz 1 Phase Width 35 in Air Delivery 90 psi 14 0 SCFM Height 70 in Air Deliver...

Страница 11: ...to the drain valve to facilitate condensate drainage IMPORTANT It is extremely important to install the compressor in a clean well ventilated area where the surrounding air temperature will not be mo...

Страница 12: ...onry bit Holes drilled must be at least as deep as the concrete wedge anchors being used 3 Inserting the mounting bolts Insert the mounting bolts into the drilled holes Place a washer on each bolt Thr...

Страница 13: ...t For units that do not have a factory installed cord install permanent wiring from the electrical source to the pressure switch with a ground conductor connected to the grounding screw on the pressur...

Страница 14: ...l 2 line terminal 3 ground screw 4 and ground line 5 3 Making the electrical connections Remove the ground screw 1 Install the strain relief on the pressure switch 2 Do not tighten the strain relief o...

Страница 15: ...Place a flathead screwdriver into the raised notch and tap the screwdriver with a hammer until tight Tighten the strain relief screws 2 to hold the power cord securely 5 Reinstalling the pressure swit...

Страница 16: ...ife of the unit you will clean or replace the filter as needed This air compressor unit can be installed as part of an air distribution system Any tube pipe or hose used in an air distribution system...

Страница 17: ...ass on the pump to determine the oil level Add oil to the pump if the oil level is low 2 2 Starting up and breaking in the compressor WARNING Do not attach air tools to the open end of the hose until...

Страница 18: ...or the drain valve may be damaged Drain the tank of moisture daily using the drain valve at the bottom of the tank IMPORTANT This condensation will cause water spots in a paint job especially when spr...

Страница 19: ...llect in the pan Reinsert the oil drain plug Remove the oil fill plug 3 Pour new unused oil into the pump Do not overfill Reinsert the oil fill plug 3 into position Return power to the compressor for...

Страница 20: ...pump The belt should be slack and easily removed Replace the belt Move the motor back to the original position to create belt tension Tighten the motor bolts 6 Aligning tensioning the belt Lay a strai...

Страница 21: ...cate or perform any maintenance Operation Daily Weekly Monthly Every 3 Months Check Oil Level X Drain Tank X Check Air Filter X Check Safety Valve X Clean Unit X Check Belt Tension X Change Oil X IMPO...

Страница 22: ...level and change the oil more frequently The piston pin bores are worn Remove the piston assemblies from the compressor and inspect for excess wear Replace the excessively worn piston pin or pistons a...

Страница 23: ...restricted Clean or replace the air filter element The electrical connections are loose Check all the electrical connections The pressure switch shut off pressure is set too high Replace the pressure...

Страница 24: ...24 Service Parts Compressor MODEL HS518102 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 30 28 29 31 32...

Страница 25: ...ut ST033001AV 1 18 Exhaust tube HS015200AP 1 19 Compression fitting ST072019AV 1 20 Air filter DP500056AV 1 21 Pump HS7101 1 22 Hex head screw ST016000AV 4 23 Washer ST077303AV 4 24 Nut 4 25 Beltguard...

Страница 26: ...Service Parts Pump MODEL HS050000AV 6 1 2 3 4 5 7 8 10 9 11 13 12 14 15 16 17 18 19 20 21 22 2 23 3 31 29 30 26 24 25 28 27 32 35 33 34 36 37 38 44 43 39 41 42 48 45 46 47 49 50 51 52 53 54 55 56 57...

Страница 27: ...ng 1 34 Compression ring 1 35 Oil ring 2 36 Piston 1 37 Wrist pin 1 38 Retainer clip 2 39 Ball bearing 1 Service Parts Pump continued Part Description Part Number Qty 40 Key 1 41 Dipper retaining scre...

Страница 28: ...s problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use Document Number IN56480...