background image

 13 HUSKYTOOLS.com

 

  Please contact 1-888-43-HUSKY for further assistance.

Starting the compressor

WARNING:

  Risk of bursting. If any unusual noise or 

vibration is noticed, stop the air compressor immediately 
and have it checked by a trained service technician.

NOTE:

 When using regulator and other accessories refer 

to the manufacturers instructions.

 

Plug the power cord into a proper receptacle.

 

Turn the ON ( I ) / OFF ( O ) switch (1) to the on 
position, and allow the tank pressure to build. 
The motor will stop when the tank pressure 
reaches “cut-out” pressure. 

 

Adjust the regulator (2) to a PSI setting that 
is needed for your application - be sure it 
is within the safety standards required to 
perform the task.

2

1

Checking the safety valve

DANGER:

 Do not tamper with the safety valve. Items 

loosened from this device could fly up and hit you. Failure 
to heed this warning could result in death or serious 
personal injury. The safety valve automatically releases air 
when the receiver pressure exceeds the preset maximum. 
Check the valve before each day of use by pulling the ring 
by hand.

WARNING:

 If air leaks after releasing the safety valve 

ring or if the valve is stuck, do not use the air compressor 
until the safety valve has been replaced. Using the air 
compressor in this condition could result in serious 
personal injury.

 

Set the ON ( I ) / OFF ( O ) switch (1) to the 
on position, and wait for the tank to fill. The 
compressor automatically shuts off when the 
pressure reaches the preset maximum.

 

Set the ON ( I ) / OFF ( O ) switch (1) to the off 
position.

 

Pull the ring on the safety valve (2) for 20 
seconds to release the air.

 

Release the ring. Air stops escaping at 
about 20 psi. If air continues to escape after 
releasing the safety valve ring, discontinue 
use and seek service before using the air 
compressor again.

2

1

Operation (continued)

Содержание C201H

Страница 1: ...to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky USE AND CARE GUIDE 20 GALLON PORTABLE AIR COMPRESSOR Quest...

Страница 2: ...s gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors away while operating tools Distractions can cause you to lose control WARNING This co...

Страница 3: ...ry or long hair can be caught in moving parts WARNING Never touch any exposed metal parts on compressor during or immediately after operation The compressor will remain hot for several minutes after o...

Страница 4: ...er direct a jet of compressed air toward people or animals Protect your lungs Wear a face or dust mask if the operation is dusty Do not use this air compressor to spray chemicals Your lungs can be dam...

Страница 5: ...et caught on lumber tools or other obstructions while you are working with a power tool Failure to do so can result in serious personal injury WARNING Check extension cords before each use If damaged...

Страница 6: ...te grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper installation of the grounding plug...

Страница 7: ...mum branch circuit requirement 15 A Fuse type Time delay Net weight 73 lbs DUTY CYCLE This air compressor pump is capable of running continuously However to prolong the life of your air compressor it...

Страница 8: ...sor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressure the check valve closes allowing air pressure to remain inside th...

Страница 9: ...ronment may cause damage to the unit NOTICE Long lengths of electrical wiring could cause power loss to the motor Place the air compressor in a clean dry and well ventilated area The air compressor mu...

Страница 10: ...or safety glasses with side shields when operating power tools Failure to do so could result in objects being thrown into your eyes resulting in possible serious injury The compressor is assembled at...

Страница 11: ...ure rating CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensation and oil mist Do not spray un fil tered air at an item that could be damaged by moisture Some ai...

Страница 12: ...ould fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve automatically releases air when the receiver pressure exceeds the preset maximum...

Страница 13: ...of air flow with the pressure regulator knob Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently Rotate the pressure regulator...

Страница 14: ...drain point e g tanks filter after coolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal l...

Страница 15: ...rts Use of any other parts may create a hazard or cause product damage WARNING Always release all pressure disconnect from power supply and allow unit to cool to the touch before cleaning or making re...

Страница 16: ...Release the air from the tank until the compressor restarts automatically The motor hums while running slowly or it doesn t run at all There is low voltage from the power source Call an electrician Th...

Страница 17: ...e or open Tighten the drain valve The check valve is leaking Bring the compressor to a service center There is excessive moisture in the discharge air There is excessive water in the air tank Drain th...

Страница 18: ...19 HUSKYTOOLS com Please contact 1 888 43 HUSKY for further assistance Service Parts C201H AIR COMPRESSOR...

Страница 19: ...Valve E109170 12 Hose Clamp Set of 2 E106648 13 Switch Rocker E106633 14 Hose E106636 15 Cup E106625 16 Screw 10 14 Plastite T20 x 75 E106646 17 Safety Valve E108520 18 Gauge E108512 19 Shroud Top E10...

Страница 20: ...part number field without a number listed is not available Descriptions are provided for reference only Item Number Description Part Number 33 Nipple 250 18 X 2 0NPT E107858 34 Label Hot Surface E106...

Страница 21: ...22 Service Parts continued PUMP MOTOR ASSEMBLY...

Страница 22: ...9 Fan Motor E108869 10 Fan Pump E108870 11 Fan Mount E108871 12 Headbolt 250 20UNC x 1 75 Set of 4 E108872 13 Head Grommet E108873 14 Screw 375 24UNF 2A x 1 25 E108874 15 Screw 250 20 x 500 E109129 1...

Страница 23: ...problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use Document Number E108331 0...

Отзывы: