Air compressor Head Bolts
- Torquing
The air compressor pump head bolts should
be kept properly torqued. Check the torques
of the head bolts after the first five hours of
operation.
Torque to 14-16 ft-lbs (19–21.7 Nm).
10
Additional Service
Disassembly or service of the air compressor
beyond what is covered in this manual is
not recommended. If additional service is
required, contact 1-888-43-HUSKY for further
assistance.
Maintenance (continued)
Storage
Before you store the air compressor, make sure you do the following:
1.
Review the
Maintenance
section on the preceding pages and perform scheduled
maintenance as necessary.
2.
Drain water from air tank. See
To Drain Tank
under
Operation
.
WARNING:
Water will condense
in the air tank. If not drained,
water will corrode and weaken
the air tank causing a risk of air
tank rupture.
Troubleshooting
Problem
Possible Cause
Solution
Compressor does
not run.
Tank has insufficient
pressure.
When the tank pressure drops, the
compressor will turn on to cut-in
pressure.
No electrical power.
Verify wiring connection inside
pressure switch and terminal box
area.
Blown stop/house fuse.
Replace the shop/house fuse.
Tripped shop/home
breaker.
Reset the shop/home breaker and
determine the underlying cause.
Thermal overload is open.
Place the Auto/Off switch in the
“Off” position.
Allow the motor to cool.
Depress the red reset button on
the motor.
Place the Auto/Off switch in the
“Auto” postion to restart the
motor.
Содержание 723883
Страница 23: ......
Страница 24: ......
Страница 43: ...19 HUSKYTOOLS COM Veuillez composer le 1 888 43 HUSKY pour une assistance supplémentaire pts 205109 051012 ...
Страница 44: ...20 Vue éclatée 1 2 3 4 5 6 7 8 9 12 13 14 22 23 24 25 26 27 28 30 31 32 33 35 36 58 55 16 15 18 19 20 21 24 ...
Страница 48: ......
Страница 68: ...20 Vista Ampliada 1 2 3 4 5 6 7 8 9 12 13 14 22 23 24 25 26 27 28 30 31 32 33 35 36 58 55 16 15 18 19 20 21 24 ...
Страница 71: ......