background image

www.spartacogroup.com 

 800-860-6170

8

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 

COMPRESSION 

1.  Consult your connector manufacturers recommendations on using a dieless compression
 

tool with the connector and cable being used. Not all connectors are suitable for dieless tool  

 

applications.

2.  Retract the indenting nibs by pressing the release button.
3.  Position the connector, and center it between the indenting nibs. Activate the trigger and 
 

advance the nibs so the connector is held in place. Check connector for correct positioning.

4.  Insert the cable into the connector and activate the trigger until 
 

the compression is completed. A series of clicks will be heard while 

 

the compression is being made, followed by the tool running in a 

 

“free” mode. This indicates a completed cycle and a full 

 

compression.

5.  Press release button to retract the indenting nibs. and remove the 
 

connector from the tool.

TRIGGER AND RELEASE BUTTON 

1.  The ram advances when the trigger is pressed 
 

and stops when the trigger is released.

2.  To retract the ram, press the release button. The 
 

ram continues to retract while the release button is 

 

pressed.

Содержание REC-6750

Страница 1: ...on Dieless Compression Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL 60139...

Страница 2: ...resent state of the art tools and be dependable and safe All products will carry an unconditional guarantee to be free from defects and to perform as advertised Please take the time to read this manua...

Страница 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Страница 4: ...tion when operating this tool Failure to wear eye protec tion could result in serious eye injury from flying debris or hydraulic oil Electric Shock hazard Use proper personal protective equipment when...

Страница 5: ...s Tri Chemistry Charger This charger can charge the BP 84 BP 82 and BP 80 only Huskie Tools batteries including the BP 70 BP 70EI and the BP 70MH must be charged with the CH 90 CH 80 or previous charg...

Страница 6: ...19 4 can be used For range taking connectors the cable must be maximum size specified for the connector Consult your connector manufacturer for dieless applications It also has an external bypass cart...

Страница 7: ...our customer service department at 1 800 860 6170 CHARGING THE BATTERY 1 While pressing the latch pull out the battery cartridge To replace the battery cartridge push the new cartridge firmly into pla...

Страница 8: ...so the connector is held in place Check connector for correct positioning 4 Insert the cable into the connector and activate the trigger until the compression is completed A series of clicks will be h...

Страница 9: ...BATTERY CARTRIDGE 1 Do not short circuit the contacts or expose the cartridge to water oil or solvents 2 Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire 3 Do not...

Страница 10: ...www spartacogroup com 800 860 6170 10 BREAKDOWN 41...

Страница 11: ...21 6 21 Body 6630 01 1 65 3 16 Ball 16 49 2 22 Ram 6750 01 1 66 M4 X 4 Screw F P 85 47 1 23 Spring 708 6630 03 1 67 M4x6 Screw D P R5PD 02 1 24 Cam Yoke Holder 6630 04 1 68 M5 X 8 Screw 410 49 1 25 In...

Страница 12: ...Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connect...