FAULT CODE
192
600849-01
400607-11
Lambda sensor - check the signal line for a short circuit to ground (terminal 31)
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
7
–
measuring point
Ground(
−
)
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
7
to connector
CU
pin
2
for a short circuit to ground (terminal 31).
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Lambda sensor - signal line has a short circuit to sensor ground (
Lambda sensor - signal line has a short circuit to sensor ground
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Lambda sensor is disconnected.
600849-01
Lambda sensor - check the signal line for a short circuit to sensor ground
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
7
–
Break Out Box
DT
Pin
24
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
7
to connector
CU
pin
2
for a short cir-
cuit to sensor ground.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Lambda sensor - signal line has a short circuit to plus (terminal 30) (
Lambda sensor - signal line has a short circuit to plus (terminal 30)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Lambda sensor is disconnected.
600849-01
400607-11
Lambda sensor - check the signal line for a short circuit to plus (terminal 30)
–
Measure the voltage between the specified points.
Break Out Box
DT
Pin
7
–
measuring point
Ground(
−
)
Voltage
< 0.1 V