Hurricane ALT55 Скачать руководство пользователя страница 5

 

  Do not unplug by pulling on cord. To unplug, grasp the plug. Not the cord. 
  Do not handle plug or machine with wet hands. 
  Regularly inspect cord and plug for damage. If cord is damaged, it must be replaced by a qualified 

person in order to avoid hazard. 

  Do not put any object into openings. Do not use with any opening blocked (accept during filter cleaning 

procedure). Keep free of dust, hair and anything that may reduce airflow. 

  Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts. 
  Turn off all controls before unplugging. 
  Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they 

may be present. 

  Do not pick up any type of liquids. 
  Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes. 
  Use extra care when cleaning on stairs. 
  Do not use without dust bag and/or filters in place. Replace collection system and/or filters as described 

in manual. 

  If using an extension cord make sure the cord rating is suitable for this machine. 
  Do not modify machine from its original design. 
  Keep children and unauthorized persons away from machine when in use. 
  All repairs must be performed by a qualified service person. Use only manufacturer-supplied or 

equivalent replacement parts. 

  Do not expose machine to rain or moisture. Store indoors only. 
  Connect to a properly grounded outlet only. See grounding instructions. 

 
THERMAL PROTECTION 

 

  The dust extractor is equipped with a safety thermal protector to prevent motor from overheating. Should 

thermal protector activate, turn off machine, unplug power cord and check for full dust bag, vacuum hose 

clog or filter blockage. It may take up to 45 minutes for the thermal protector to reset.

 

 

GROUNDING INSTRUCTION 

 

  The dust extractor must be grounded. If it should malfunction or breakdown, grounding provides a path of 

least resistance for electric current to reduce the risk of electric shock. The dust extractor is equipped with 

a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an 

appropriate outlet that is properly installed and grounded in accordance with all local codes and 

ordinances. 

 

SAFETY LABEL 

 

  The following label appears on the machine, next to the machines rating plate. Replace label if it is   

missing, becomes damaged or illegible. Failure to follow this warning label may result in fire,electric shock 

or injury 

 

3.Function 

ALT55

 equipped with a three phase powerful turbine motor. The machine has three HEPA filters 

inside, is for sucking and separating dry, non-combustible dust with an explosion limit value of 
0.1mg/m3 
 

The  m otor  is  started  by  switches.  Dust-laden  air  is  then  sucked  through  the  inlet  valve  at  high 

speed via the suction hose. The air is slowed down by the cyclone and coarse dust particles are 

Содержание ALT55

Страница 1: ...INSTRUCTIONS MANUAL ALT55 DUST EXTRACTOR...

Страница 2: ...3 Please pay particular attention to the safety regulations and safety instructions 4 Read the complete instruction manual before using 5 All spare parts and accessories used with this device must be...

Страница 3: ...SAFETY INSTRUCTIONS 1 3 Function 2 4 Filter cleaning 5 Filter change 3 3 6 Dust Storage System 3 7 Maintenance 8 Warranty 4 4 9 Problem solving 10 Technical data 5 6 11 ALT55 Dust extractor Diagram an...

Страница 4: ...ther the outlet is properly grounded Do not modify the plug provided with the machine If it will not fit the outlet Have a proper outlet installed by a qualified electrician Before using the machine m...

Страница 5: ...rain or moisture Store indoors only Connect to a properly grounded outlet only See grounding instructions THERMAL PROTECTION The dust extractor is equipped with a safety thermal protector to prevent m...

Страница 6: ...emoval Only use original parts 5 Filter change Risk of dust dispersion Use of personal safety equipment Unhealthy dust can be spread during filter change Accordingly the user should wear protective gl...

Страница 7: ...ible use a special suitable room Proper personnel protective equipment must be used All parts which are contaminated after service must be carefully disposed of in plastic bags according to local regu...

Страница 8: ...doesn t start No power Plug in machine Cable defective Replace cable Switch defective Replace switch Soft start defective Replace soft start Motor stops immediately after starting Wrong fuse Connect...

Страница 9: ...7 5 8 6 Voltage V Hz 380 50 380 50 480 60 380 50 480 60 Max Vacuum mbar 260 300 320 320 350 Max air flow m3 h 420 530 620 530 620 Inlet mm 70 Filter area m2 3 5 3 5 3 5 3 5 3 5 Filter capacity 0 3 m...

Страница 10: ...turbine motor 4 Electrical connector 5 8 inch rear wheels 6 4 lockable front swivel casters 7 Drop down poly bag disposal Longopac compatible 8 Flap Assembly kit 9 Powder coated stainless steel barre...

Страница 11: ..._________________________________ ___________________________________________________________________ ___________________________________________________________________ ______________________________...

Отзывы: