background image

INST 332 PZ200 Filtrite Pool & Spa Pump V10-20 
 

OPERATION 

 
1.

 

Switch on power to pump, motor to start. 

 
2.

 

If some flow of water does not establish within on half minute, switch off and prime pump again.  If pump does not prime 
within 3 attempts, check all suction connections for sealing.  If these are satisfactory, a check or foot valve is required to 
hold water for prime. 

 
3.

 

If the water flow through pump is always tedious to obtain at start-up after cleaning the lint basket, then an examination 
of the system to establish a reason and correct the cause is recommended. Eg. Check valve, air leaks, faulty seal, cracked 
lint pot lid, etc. 

 
4.

 

The PZ200 has 2 set speed settings – Low and High. High should be used when backwashing, manually vacuuming the pool 
or operating spa jets or some water features such as waterfalls.   Low speed can be used for gentle spa jet action, when 
suction cleaner is connected to the skimmer or filtration for the pool.   Low is the recommended setting for everyday 
filtration of your pool when a cleaner is not connected. 

 
5.

 

The PZ200 will automatically start on High for the first 5 minutes to assist in priming and substantially fill the hair and lint 
pot with water.    After 5 minutes the pump will revert to the last speed it was set at before it was turned off. 

 
6.

 

During normal operation, it is recommended that the pump be operated on Low for 12 hours per day. This will achieve 
the lowest operating costs with the lowest noise level.   Should your pool have areas where water is not turning over 
when pump is on Low, increase the speed setting. 

 
Notes: The appliance is not intended for use by person including young children or infirm persons with reduced    physical, 
sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety. 
Please ensure that young children are supervised to ensure that they do not play with the pump. 
  
To avoid a safety hazard, the supply cord if damaged, must only be replaced by AstralPool, or its service agent or a suitably 
qualified person. 
 
 
Hours of Operation 
 
On low speed your PZ200 pump makes very little noise and is unlikely to be intrusive to you or your neighbor’s.  Generally, 
your pool filter pump should operate for a minimum of 8 hours a day to provide sufficient skimming (thereby reducing the 
amount of debris that falls to the bottom of the pool) and to allow the chlorinator to provide sufficient chlorine to sanitise 
your pool. 
 
Greater energy savings occur when operating the pump for longer periods at the low speed instead of operating for shorter 
periods at the high speed. 
 

 

 

Содержание Filtrite PZ200

Страница 1: ...and national installation codes standards and any other local applicable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Fai...

Страница 2: ...reduce the risk of property damage or injury do not attempt to change the backwash multiport slide or full flow valve position with the pump running WARNING AstralPool Pumps are powered by a high vol...

Страница 3: ...for operation Notice These parameters apply to AstralPool equipment only For non AstralPool equipment consult the equipment manufacturer WARNING Chemical spills and fumes can weaken pool spa equipmen...

Страница 4: ...The system must be built to include at least two 2 suction outlets drains connected to the pump whenever the pump is running However if two 2 suction outlets run into a single suction line the single...

Страница 5: ...y a pool professional trained by Clark Rubber to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FEATU...

Страница 6: ...filters heaters chlorinators must have a minimum of 50mm connections C Secure the barrel unions supplied into the attaching pipe work using approved priming fluid and solvent cement as normal practice...

Страница 7: ...t speed it was set at before it was turned off 6 During normal operation it is recommended that the pump be operated on Low for 12 hours per day This will achieve the lowest operating costs with the l...

Страница 8: ...High Speed Operating Spa Jets High Speed Low Speed or High Speed depending on effect required Cleaning up pool with Cloudy Water Up to 24 hours on High Speed General Filtration Low Speed 8 hours in w...