EN
18
●
When there is thunderstorm or lightning outside, it is necessary to turn off the main
power switch in order to avoid damaging the machine by a lightning stroke.
●
Do not use heavy and sharp things, they can damage the machine housing or bowl
surfaces.
●
After completion of work, turn off the main power switch.
●
The machine installation and the support of electromechanical elements should be
carried out only by skilled personnel.
●
If the power cable is damaged, then for the purpose of safety the user shall contact
the manufacturer or the technical support department for replacement.
Attention!
●
In the course of operation, your hands, male connector and machine switch should be
dry.
●
The oil level should not be below the minimum mark. Do not switch the machine for
operation on idling.
●
It is not allowed to wash the electrical junction box by direct water flow or soak it.
●
It is not allowed to use old oil as it can lead to overboiling.
●
Cooking of excessively moist product as well as large volume products at a time can
lead to an accident.
Fault
Cause
Remedy
1. After connection of power
supply, the light indicator does
not come on and no heating
occurs.
1. The male connector does
not adhere tightly.
2. The microswitch contacts
are not connected correctly.
1. Replace the male
connector.
2. Adjust the limit
distance
of
the
microswitch.
2. The light indicator is alight but
the temperature does not rise.
1.
The
electrical
heater
connection gets loose.
1. Match and tightly
screw both parts of
the electrical heater.
2.
Replace
the
electrical heater.
3. The light indicator is alight but
the temperature does not rise to
the normal level.
1. The temperature controller
has burnt out.
1.
Replace
the
controller.
4. The temperature control is
performed but the indicator is not
alight.
1. The indicator has burnt out. 1.
Replace
the
indicator.
5. After heating the circuit, no
heating of the electrical heater
occurs.
1. The temperature limiter has
operated.
1.
Press
the
"Machine restart in
case of overheating"
button.
6. No temperature control is
performed.
1. The temperature limiter has
failed.
1.
Replace
the
temperature limiter.