Introduction
Section 1
List of Abbreviations
Page 5
Belt Conveyor System
4330053_A7
SGR | SPV
1.3
List of Abbreviations
Abbreviation
Definition
CE
Communauté Européene
European Community
DGUV
German Statutory Accident Insurance (
Deutsche Gesetzliche Unfallversicherung e.V.
)
DIN
German Institute for Standardisation, technical regulations and technical specifications
E/V
Spare or wearing part (
Ersatz- bzw. Verschleißteil
)
EC
European Community
European Community
EN
European Standard (
Europäische Norm
)
Harmonised standard for the EU market
HACCP
Hazard Analysis and Critical Control Points
Hazard analysis of critical control points
IP
International Protection. The abbreviation IP and a further two-digit index specify the
protection class of a housing.
The first digit: Protection against ingress of solid foreign objects
The second digit: Protection against ingress of water
0
No protection against contact, no
protection against ingress of solid foreign
bodies
0
No protection against ingress of water
1
Protection against contact with any large
surface of the body such as the hand,
protection against ingress of foreign
objects
Æ
> 1.97'' (50 mm)
1
Protection against dripping water
(vertically falling drops)
2
Protection against contact with the
fingers, protection against ingress of
foreign objects
Æ
> 0.5'' (12 mm)
2
Protection against dripping water (at any
angle up to 15° from the vertical)
3
Protection against contact with tools,
wires or similar objects of
Æ
> 0.1''
(2.5 mm), protection against foreign
objects
Æ
> 0.1'' (2.5 mm)
3
Protection against water drips at any
angle up to 60° from the vertical
4
Protection against contact with tools,
wires or similar objects of
Æ
> 0.04''
(1 mm), protection against foreign
objects
Æ
> 0.04'' (1 mm)
4
Protection against water splashing from
any direction
5
Protection against contact, protection
against dust deposits inside
5
Protection against water jets (projected
by a nozzle) at any angle
6
Complete protection against contact,
protection against ingress of dust
6
Protection against rough sea or strong
water jets (flood protection)
7
Protection against ingress of water
during temporary immersion
8
Protection against pressurised water
during continuous immersion
LED
Light Emitting Diode
Light diode
LMHV
Regulation on the hygiene of foodstuffs
RCD
Residual Current Device
Residual current device (RCD)
STB
Safety temperature limiter
VDE
Association of Electrical Engineering, Electronics and Information Technology (
Verband
der Elektrotechnik, Elektronik und Informationstechnik e.V.
)