Page 11 of 24
Hunting Energy Services (Well Intervention) Ltd
4.2 Annually
Disassemble and inspect as per the routine maintenance procedure.
Renew all o-rings, inspect sealing surfaces for wear, corrosion or damage.
Rebuild and pressure test to Maximum Working Pressure.
4.3 5 Year Major Survey
Disassemble and inspect as per the routine maintenance procedure.
Dimensional and thickness report.
Magnetic Particle Inspection (MPI) of all parts.
Rebuild using seal kit and any necessary parts.
Hydrostatic body test to Maximum Working Pressure.
Third party certificate of final test and inspection and certificate of conformity.
4.4 Recommended Lubricants/Chemicals:
Grease
Grease anti seize
Lubriplate
WD40
Содержание X-Over
Страница 1: ...X Over Tool Manual Manual Revision Prepared Checked Approved Date C P Kinnaird 09 06 2017 ...
Страница 15: ...Page 15 of 24 Hunting Energy Services Well Intervention Ltd Annex I Quick Union Table ...
Страница 16: ...Page 16 of 24 Hunting Energy Services Well Intervention Ltd ...
Страница 17: ...Page 17 of 24 Hunting Energy Services Well Intervention Ltd Annex II Torque Value Chart ...
Страница 18: ...Huntin ng Energy Se ervices Well l Intervention n Ltd Page 18 o of 24 ...
Страница 19: ...Page 19 of 24 Hunting Energy Services Well Intervention Ltd Annex III API Flanges ...
Страница 20: ...Page 20 of 24 Hunting Energy Services Well Intervention Ltd ...