11
Competent Persons Scheme
Members of the following schemes may self-certify the installation of this stove. If the installer is not a
member of one of these schemes, your local Building Control Department must approve the installation.
Scheme
Web address
Telephone
APHC (Association of Plumbing and
Heating Contractors (Certification)
Limited
02476 470 626
Building Engineering Services
Competence Accreditation (BESCA
Limited)
www.hvca.org.uk / www.besca.org.uk 0800 652 5533
HETAS Ltd (Heating Equipment Testing
and Approval Scheme)
01462 634721
NAPIT Registration Ltd
0870 444 1392
NICEIC Group Ltd
0800 013 0900
Air Supply
The room or space containing this appliance does need a permanent, unobstructed air opening of at least
6,325mm². If a draught stabiliser is fitted, the air opening should be at least 10,700mm². Due consideration
should be given to air requirements for any other appliance in the same room or space. Any air opening must
be kept clear from blockage or obstruction.
H
EARTH
/
M
ATERIAL
C
LEARANCES
Hearth constructions must comply with the current building regulations.
Your stove must be installed on a floor with adequate load-bearing capacity, otherwise suitable measures
should be taken.
If the existing construction does not meet this pre-requisite, suitable measures (e.g. load distributing plate)
should be put in place.
Care should be taken to level the stove using the adjusting screws in the feet.
MATERIAL CLEARANCES
COMBUSTIBLE MATERIAL
Minimum Distances to Combustible Material
Behind the stove
175mm
At the side of the stove
200mm
In front of the stove
900mm
**Note:
Combustible material refers to any material that will degrade when subjected to heat e.g. plaster.