44276-01 02/18/2013
11
1.Use of standard light rheostat or continuously variable fan speed wall control will always cause
harmonic distortions, or a humming noise. Many fan motors do not work quietly with solid state
variable controls. If a quiet wall control is desired,use only 3-speed NOM approved wall controls.
2.Always allow a few days
"
break in
"
time for any new fan at medium or high speed. Try todiagnose
the exact location of the noise by listening carefully from several sides (Blades,Motor,Light
Fan noise can come from a light kit.
3.Make sure all screws in the fan assembly and light kit are tight and properly threaded.If not, back
out and retighten. Tighten these screws at least once a year because they may loosen slowly
over time and cause a clicking noise.
4.Make sure the light kit is securely fastened to the fan and all glass screws are finger tightened
only. Do not tighten with pliers or a screw driver.
5.Make sure mounting bracket is installed snugly to junction box.
6.Make sure wire nuts in switch housing or canopy are not rattling against each other or against
wall of housing. Wrap with electrical tape if necessary.
7.Make sure the canopy is not touching the ceiling.
8.Assure that the screws fastening blade Arm to motor are tight and the lock washers provided for
that purpose have been used.
Kit, etc ...).
.