background image

7

©2009 Hunter Fan Co. 

43086-01   20090305

figure 11.

figure 10.

Grill Release 

Handle

3. Lift the Filter Tab and gently pull the 

filter out of the unit. Refer to Figure 

11. While removing the filter, note the 

When the PERMAlife 

Filter Life Counter 

reaches “00%” 

(approximately 6 months 

of use), you should 

check the filter to see if it 

needs to be cleaned. The proper time to clean 

the filter depends on usage and the 

environment. Generally, if you notice a 

decrease in air output or an increase in noise 

at any time during normal operation, the filter 

may be clogged. Clean the filter to return to 

normal operation. 

To clean the filter and reset the Filter Life 

Counter: 

1. First, turn off and unplug the Air Purifier.

2. Next, remove the Front Grill.  Place your 

fingers under the Grill Release Handle and 

pull up. Refer to Figures 10. and 11.

CleanIng THe PermalIfe fIlTer

NOTE

: Ensure the grill is completely dry 

before reinstalling it on the unit. Failure to 

do so could cause damage to the filters or 

motor.

CleanIng THe Carbon/Pre-fIlTers

When the Pre-Filter 

exceeds 1400 hours, the 

Pre-Filter indicator will 

flash “00%” as a 

reminder that you should 

clean the Pre-Filter and 

change the Carbon Odor Filter. To maintain 

proper odor-removing capability and overall 

filtration performance, the Pre-filters should be 

cleaned and the Carbon Odor filters replaced 

every 1400 hours (approximately 3 months of 

use). If necessary, clean the pre-filter and 

change the odor filter more often. 

To clean the Pre-Filters, Change the Carbon 

Odor Filter, and reset the Pre-Filters & Carbon 

Odor Filter Life Counter:

1. First, turn off and unplug the Air Purifier.

2. Next, remove the front grill.  Refer to Figs. 

3 and 4.

3. Remove the Pre-Filters. Refer to Figure 2. 

Use a vacuum cleaner to remove dust from 

them. Then, reinsert the Pre-Filters into the 

Air Purifier.

4. The Carbon Odor Filter is held to the back 

of the Front Grill with four hook-and-pile 

fasteners. Peel off the old Carbon Odor 

Filter. 

5. If needed, use a soft damp cloth to wipe off 

the Front Grill. Gently press a new filter into 

place.

6. Place the Front Grill back onto the unit.  

7. Plug in the Air Purifier.

8. To reset the Pre-Filters & Carbon Odor 

Filter Life Counter to zero, press and hold 

the Pre-Filters & Carbon Odor Filter Reset 

Key for 3 seconds. When the display shows 

100%, release the Key. The Counter is now 

reset.

Содержание PermaLife 30795

Страница 1: ...PermaLife PermaLife PermaLife Form 43086 01 20090305 2009 Hunter Fan Co English Air Purifier Owner s Manual Model 30795 ...

Страница 2: ...ls from the air It also traps lint hair and other large particles to help extend the life and performance of the PermaLife filter Ionizer The ionizer improves the quality of air in the room by releasing negative ions into the air that attract positively charged dust smoke and pollen particles Filter Counter Filter maintenance is critical to the performance of the air purifier To help you determine...

Страница 3: ...pt to defeat or override this safety feature 5 ALWAYS UNPLUG the Air Purifier when it is not in operation while the filter is being changed and while it is being cleaned 6 DO NOT tilt or move the Air Purifier while it is in operation Shut off and unplug before moving 7 DO NOT immerse the Air Purifier in water as permanent damage will occur Refer to and follow the CLEANING AND FILTER REPLACEMENT in...

Страница 4: ...r is secure and the top of the filter is behind the filter tab Refer to Figure 5 Filter Filter Tab Figure 5 Figure 3 Grill Release Handle For your convenience a remote control is provided with this air purifier The remote may be used to turn the air purifier on or off and adjust the fan speed Operating the Air Purifier with the remote 1 Install two AAA batteries UM 4 or IEC R03 or equivalent Refer...

Страница 5: ...y the fan The pre filters on each side of the unit attracts larger particles like pet dander hair and odor causing particles and traps them on the pre filter Smaller particles such as dust mold and pollen are captured by the PermaLife filter The pre filter then captures any remaining particles and reduces odors before air is emitted back into the room Up to 99 95 of particles as small as 5 microns...

Страница 6: ...in soapy water after it has been removed from the unit and the pre filter has been removed See Figure 1 Cleaning Unit off Low speed Recommended for use when soft background noise is unwanted Medium speed Typical usage setting Soft background noise is not an issue High speed Use when quick efficient results to a room s air quality are desired Ionizer on run the ionizer to assist the filters in clea...

Страница 7: ...e Pre Filter indicator will flash 00 as a reminder that you should clean the Pre Filter and change the Carbon Odor Filter To maintain proper odor removing capability and overall filtration performance the Pre filters should be cleaned and the Carbon Odor filters replaced every 1400 hours approximately 3 months of use If necessary clean the pre filter and change the odor filter more often To clean ...

Страница 8: ...set the Air Purifier 1 Unplug the unit for at least 30 seconds 2 Plug the unit back in Resetting the Air Purifier Filter Filter Tab Figure 12 4 Place the bottom of the filter rim behind the ridges on each side of the bottom of the unit and snap into place Refer to Figure 13 Figure 14 5 Place the grill over the front of the Air Purifier and lower it into position Figure 14 RIDGE Figure 13 filter s ...

Страница 9: ...IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE This warranty is voided if the air purifier is not purchased and used in the USA or Canada This warranty excludes and does not cover defects malfunctions or failures of the Air Purifier which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling modifications or ...

Страница 10: ...freight prepaid The Air Purifier should be properly packaged to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL...

Отзывы: