background image

www.HunterFan.com

1.888.830.1326

M0035-01 • 05/28/13 • © Hunter Fan Company

17

Troubleshooting

    Excessive wobbling

•  Tighten all of the blade and 

blade iron screws until they 
are snug.

•  Use the provided balancing 

kit and instructions to balance 
the fan.

    Noisy Operation

•  Tighten the blade and blade 

iron screws until they are snug.

•  Check to see if any of the 

blades are cracked. If so, replace 
all of the blades.

    Fan doesn’t work

•  Make sure power switch is on.

•  Pull the pull chain to make sure 

it is on.

•  Push the motor reversing switch 

firmly left or right to ensure that 
it is engaged.

•  Check the circuit breaker to 

ensure the power is turned on.

•  Make sure the blades spin freely.

•  Turn off power from the circuit 

breaker, then loosen the canopy 
and check all the connections 
according to the wiring diagram 
on page 7.

•  Check the plug connection in 

the switch housing.

Hunter fans have the power to cut your cooling costs up 
to 40%.

Beat the High Cost of Cooling

The air movement created by a Hunter ceiling fan 
lets you set your thermostat higher and still stay 
comfortable. Every degree you raise the thermostat 
saves up to 7% on energy costs. So, you can cut back on 
expensive air conditioning ... and save up to 40%* on
cooling. In winter, your Hunter fan recirculates warm air 
and saves up to 10%* on heating bills.
* On average at low speed settings. Your savings may 
vary based on climate, building type and thermostat 
setting.

Save Energy and Money While Protecting 
the Environment 

Congratulations! You’re saving energy and money while 
protecting the environment by purchasing this ENERGY 
STAR qualified Hunter ceiling fan! With this purchase, you 
are doing your part to protect the environment. In 2010, 
ENERGY STAR qualified ceiling fans are projected to cut 
air pollution by more than 500 million pounds!
Your new ceiling fan has earned the ENERGY STAR label
because it meets high energy efficiency specifications 
set by the Environmental Protection Agency (EPA). 
ENERGY STAR labeled ceiling fans save energy because 
they have more efficient fan motors and air delivery due 
to more aerodynamic blade configurations. Ceiling fan 
models bearing the ENERGY STAR label move air 14 - 
20% more efficiently than typical ceiling fan models.
For more information on ENERGY STAR visit www.
energystar.gov.

Содержание M0035-01

Страница 1: ...Options PA G E 16 PA G E 17 Congratulations on purchasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world ...

Страница 2: ...t lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Hunter Solid State Speed Controls w 4 To reduce the risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert fore...

Страница 3: ...830 1326 Tools Needed Screwdrivers Ladder Pliers Wire Strippers Power Drill optional 9 64 Drill Bit optional If mounting to a support structure you will also need these tools 11 32 Wrench 3 M0035 01 05 28 13 Hunter Fan Company ...

Страница 4: ...t common If you have a flat ceiling Hang your fan by a standard downrod included Mounting Options Use Standard Mounting or Low Profile Mounting to hang the fan from a flat ceiling Use Angled Mounting to hang the fan from a vaulted or angled ceiling 4 34O CEILING WALL OPTION 1 Standard Mounting OPTION 2 Angled Mounting 2 3 SLIDE toward ceiling PLACE against wall 1 FOLD on dotted line 34 Use the thr...

Страница 5: ...with the holes in the ceiling bracket Install the four ceiling plate screws found in the hardware bag and secure with the flange nuts using an 11 32 wrench Hold the ceiling bracket assembly up to the outlet box and mark the screw locations To mount to support structure also mark the ceiling for drilling pilot holes Install the ceiling plate gasket onto the ceiling plate The four holes in the ceili...

Страница 6: ...and washers when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag Use machine screws provided with outlet box and washers when securing to existing ceiling fan rated outlet box Make sure it is securely installed and is acceptable for fan support of 31 8 kg 70 lbs ...

Страница 7: ...he motor Save the screws They will be needed for blade iron installation Note Some fans will have a shipping ring instead of shipping blocks Please remove the ring and save the screws Time Saver Tip Get a helper to insert grommets found in the hardware bag into the blades while you re doing the next couple of steps 7 M0035 01 05 28 13 Hunter Fan Company ...

Страница 8: ...orter Downrod for fans installed close to ceiling Standard Downrod for ceilings 8 10 high Option 1 Option 2 Option 3 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new pipe Included pre assembled www HunterFan com 8 M0035 01 05 28 13 Hunter Fan Company ...

Страница 9: ...od at least 4 5 full turns until it stops The wires can be cut but leave at least 8 extending from the top of the downrod Downrod continued 8 3 8 Tighten the setscrew with pliers DO NOT HAND TIGHTEN If the setscrew is not tightened securely the fan may fall KEEP 1 888 830 1326 www HunterFan com 9 M0035 01 05 28 13 Hunter Fan Company ...

Страница 10: ... Fan Company www HunterFan com Downrod continued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fan ...

Страница 11: ...pe Note To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight FROM FAN Using the orange wire connectors from the hardware bag connect the black wire ungrounded from the ceiling to the black and the blue wires from the fan Connect the white wire grounded from the ceiling to the white wire from the fan Using an orange wire conne...

Страница 12: ...ompany Canopy Lift the canopy into place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Screw Holes Insert the two canopy screws found in the hardware bag Note Fan style may vary ...

Страница 13: ...tly attach the blade irons to the motor with the blade iron armature screws then securely tighten after both screws are attached Remember the screws that you kept after removing the shipping blocks page 7 You need them for this step Your blades are shielded with Dust Armor which is a nanotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Clean...

Страница 14: ...tch housing assembly screws from the hardware bag halfway into the motor housing It does not matter which two screw holes you choose Insert the third screw found in the hardware bag into place and then tighten all three screws Make sure the upper switch housing is securely attached to the mounting plate Failure to properly secure all 3 assembly screws could result in the switch housing fixture fal...

Страница 15: ...ngs on the plug connectors Screw Holes Connect the fan pull chain pendant to the short chain coming from the switch housing ON Turn Power Lift the lower switch housing until the screw holes are aligned with the screw holes in the upper switch housing Install the three switch housing screws found in the hardware bag 15 M0035 01 05 28 13 Hunter Fan Company ...

Страница 16: ...intenance Cleaning Changing the direction of air flow move the reverse switch to the opposite position Cleaning the fan use soft brushes or cloths to prevent scratching Cleaning products may damage the finishes Reverse Switch The pull chain controls the fan from high to off CONGRATULATIONS YOU RE DONE ...

Страница 17: ...nd still stay comfortable Every degree you raise the thermostat saves up to 7 on energy costs So you can cut back on expensive air conditioning and save up to 40 on cooling In winter your Hunter fan recirculates warm air and saves up to 10 on heating bills On average at low speed settings Your savings may vary based on climate building type and thermostat setting Save Energy and Money While Protec...

Отзывы: