background image

Setting Current Date and Time

1.  Turn the dial to the 

SET CURRENT DATE/TIME position.

2.  The year will be flashing in the display. Use the 

or

 –

 button to change the year. 

Press the 

 button to proceed. 

3.  The month will be flashing. Use the 

or

 –

 button to change the month. 

Press the 

 button to proceed. 

4.  The day will be flashing. Use the 

or

 –

 button to change the day. Press the 

 button 

to proceed and set the time. 

5.  Use the 

or

 –

 button to select AM, PM, or 24 HR. Press the 

 button. 

6.  Use the 

or

 –

 button to set the hour. Press the 

 to set the minutes. 

7.  Use the 

or

 –

 button to change the minutes.

Setting Program Start Times

Note:   A single watering start time will start the program (A,B,C,D), and all stations assigned to the program 

will run sequentially. Multiple start times can be used to activate multiple waterings in a day. The I-CORE 

controller can operate two programs at the same time. If the start times coincide or overlap across 

programs, they will operate simultaneously. 

1.  Turn the dial to the 

SET PROGRAM START TIMES position. 

2.  Select program A, B, C, or D by pressing the 

PRG button. 

3.  Use the 

or

 –

 button to change the start time. Press the 

 button to select an additional start 

time, if required, or press the 

PRG button to change between Programs A, B, C, and D to assign 

a start time to another program. 

4.  To eliminate a 

PROGRAM START TIME, press the 

or

 –

 button to set the start time off with 

dashed lines  --:-- , indicating no start time (between 11:45 PM and midnight).

Setting Station Run Times

1.  Turn the dial to the 

SET STATION RUN TIMES position. 

2.  The display will show the station number and program. Use the 

PRG button to select a program. 

3.  Use the 

or

 –

 button to change the station run time on the display. 

4.  Use the 

 button to advance to the next station for which you would like to enter a run time. 

Setting Days to Water

The days to water can be programmed individually for each of the four Programs.

1.  Turn the dial to 

SET DAYS TO WATER position. 

2.  Use the 

PRG button to select your desired program (A, B, C, or D). 

3.  Use the 

 or 

 button to change from: Specific Days of the Week, Odd Day Watering, Even Day 

Watering, or Interval Day Watering. Each program can only be assigned one type of water day.

Selecting Specific Days of the Week to Water

1.  Use the 

PRG button to select your desired program (A, B, C, or D).

2.  Use the 

 or 

 button to select 

DAYS Of ThE WEEk watering mode. Water days will be 

displayed at the bottom of the screen. Press the 

+

 button to activate the day or the 

 button to 

cancel watering for that day. A 

 indicates a water day.

Selecting Odd or Even Days to Water 

1.  Use the 

PRG button to select your desired program (A, B, C, or D). 

2.  Press the 

 or 

 button until 

ODD DAYS or EvEN DAYS is shown on the display. 

3.  You can select 

NO WATER DAYS when watering will NOT take place. Use the 

 or 

 buttons to 

navigate to that day. Press the 

+ button on a specific day, an X will appear indicating that the day 

is a 

NO WATER DAY. Note: The 31st of any month and February 29th are always Off days when 

Odd watering is selected.

Selecting Interval Watering

1.  Use the 

PRG button to select your desired program (A, B, C, or D). 

2.  Press the 

 or 

 button until 

INTERvAl DAYS is displayed. The interval will be flashing. 

Use the 

or

 –

 button to select the interval of days on which watering will occur. 

3.  Press the 

 button to program days remaining until the next watering. One day remaining means 

it will begin watering the next day. 

4.  In the interval mode you can select 

NO WATER DAYS when watering will NOT take place. Use 

the 

 or 

 buttons to navigate to that day. Press the 

+

 button on a specific day, an X will appear 

indicating that the day is a 

NO WATER DAY.

Seasonal Adjustment

Seasonal Adjustment can be used to make run time changes without having to reprogram all of the 

individual station run times. Three separate seasonal adjust modes that can be used independently 

for each program. 
1.  Turn the dial to 

SET SEASONAl ADJUSTMENT. Use the PRG button to select the desired 

program. 

2.  Press the 

or

 –

 button to select seasonal adjust mode. 

3.  Use the 

or

 –

 buttons and 

 or 

 buttons to program seasonal adjustment values. 

Global Seasonal Adjust (PRG Global) – A program global seasonal adjustment, which increases 

or decreases all station run times within a program by a fixed % from 0% to 300%. 
Monthly Seasonal Adjust – All of the seasonal adjustment values for the full year can be 

pre-programmed into the controller. Each month, the controller will automatically switch to the new 

seasonal adjust value. 
Solar Sync Adjust – This mode allows seasonal adjustment to occur on a daily basis when a 

Hunter Solar Sync is connected to the controller. 

Set Pump Operation

The Pump/Master Valve circuit is set 

ON or Off by station, regardless of which program the station 

is assigned.
1.  Turn the dial to 

SET PUMP OPERATION position.

2.  Press the 

 or 

 buttons to select a particular station. 

3.  Use the 

or

 –

 button to turn the Pump/Master Valve circuit 

ON or Off for a particular station. 

4.  Repeat steps 2 and 3 for all necessary stations.

Cycle and Soak

Cycle and Soak allows you to split each station’s run time into shorter watering durations.  

This feature is particularly useful when applying water to slopes and tight soils so that water is 

applied more slowly, helping to prevent run off from occurring.
1.  Turn the dial to 

CYClE AND SOAk position.

2.  Use the 

 or 

 buttons to select the station that you would like to program cycle and soak.

3.  Use the 

or

 –

 button to set the cycle time.

4.  Use the 

 button to select the soak time. Use the 

or

 –

 button to set the soak time.

Manual Operation

Enables immediate operation of a single station or a program. You may run more than one manual 

program or station at the same time (up to 5 stations). To initiate multiple events you will need to 

turn the dial from 

MANUAl OPERATION to RUN and then return to the MANUAl dial position to 

begin the initiation of another event. Use the 

 or 

 buttons to navigate through the manual feature 

selections. When the 

 cursor is pointing to the selection you want, simply press the 

+

 button to 

select the feature.

Rain Sensor Bypass

If the sensor is preventing system operation and irrigation is required, move the rain sensor bypass 

switch to 

BYPASS to deactivate the sensor input to the controller.

Advanced Features

The I-CORE controller has a wide variety of more advanced features in addition to standard 

programming. Please consult your I-CORE owners manual for more details on how to use  

these features.

The Irrigation Innovators

www.hunterindustries.com     © 2009 Hunter Industries Incorporated     23-775     9/09