Hunter Hardwick 50593 Скачать руководство пользователя страница 2

1886

Ladder

9/64” Drill Bit

Drill

Screwdriver

Pliers

Wire Strippers

OPTIONAL

If mounting to a support structure, you will also need these tools.

Congratulations on purchasing your new Hunter

®

 ceiling fan!

Here are the tools you’ll need to complete your installation:

1

The ceiling fan you purchased will provide comfort and performance in your home or office for many years. This instruction manual contains 
complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the 
best ceiling fan available anywhere in the world.

We are here to help!

This Instruction Manual is designed to make installation as simple as possible. While working through this Instruction Manual, keep 
your smartphone or tablet nearby. We have added video links to help you through the more technical sections. If you are unfamiliar or 
uncomfortable with wiring, contact a qualified electrician. We also provide telephone support at 1.888.830.1326 or visit us  
at HunterFan.com.

WARNING

READ and SAVE These Instructions

Warning

w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the 

mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you 

cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 – To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between 

rotating fan blades.

Caution

c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician. 
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions 

may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

•  Reorient or relocate the receiving antenna. 
•  Increase the separation between the equipment and receiver. 
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
•  Consult the dealer or an experienced radio/TV technician for help.

Caution: modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation.

This product conforms to UL Standard 507.

© 2019 Hunter Fan Company 
7130 Goodlett Farms Pkwy, Suite 400
 Memphis  TN  38016

Содержание Hardwick 50593

Страница 1: ...Installation Manual 2019 Hunter Fan Co Model 50593 Matte Black 50597 Matte Silver 51331 Fresh White Fan weight 2 lbs 21 5 lbs 9 8 kg Hardwick PG3848 r121619 ...

Страница 2: ... risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades Caution c 1 All wiring must be in accordance with national and local electrical codes ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician c 2 Use only Hunter replacement parts This equ...

Страница 3: ...x2 For installing the hanger bracket and wiring the fan For installing the blades For installing the canopy For installing the light kit Bulbs Motor Blade Downrod Canopy Canopy Screw Ceiling Bracket Wood Screw Wire Nut Washer bag Hunter Pro Tip Find a part that is missing or damaged Don t take it back to the store Let us make it right Visit us at HunterFan com or call us at 1 888 830 1326 Here is ...

Страница 4: ...port Structure Ceiling Outlet Box required Angled Mounting If you have a flat ceiling Hang your fan by a standard downrod Some fans come with a shorter downrod for a Low Profile installation Support Structure Ceiling Outlet Box required Standard Mounting A little more information on Angled Mounting For optimum performance and appearance a longer downrod should be used with your Hunter ceiling fan ...

Страница 5: ... the provided Hunter ceiling bracket that came in your fan s box Installing the Downrod Follow below if you are using the downrod that came pre assembled in your box Need to install a longer or shorter downrod Check out the guide at the end of this manual 8 3 8 C U T S T R I P not to scale Pass all wires to one side of horizontal bar in downrod assembly Hand tighten the downrod at least 4 5 full t...

Страница 6: ... Control Hanging the Fan Progress Check Your fan should look like this S l i d e c a n o p y o v e r d o wnrod and wires Place the downrod ball into the slot in the ceiling bracket NOTICE To prevent damage to fan ALWAYS lift holding either the fan housing or the downrod ...

Страница 7: ...to the blue wire from the fan Connect the three grounding wires green green yellow stripe or bare copper coming from the ceiling downrod and hanging bracket Connect the black ungrounded wire from the ceiling to the black wire from the fan B l u e Black Green Yellow Stripe White Ungrounded Ungrounded light Grounded Grounding G r e e n Y e l l o w S t ripe x4 bag Wire Nut WARNING All wiring must be ...

Страница 8: ...the tool do the work A magnetic screwdriver will give you more visibility when securing the canopy Hunter Pro Tip Fan style may vary Note Installing the Blades Repeat x5 x15 bag Blade Screw x15 bag Blade Washer Put the blade washers found in the hardware bag onto the blade screws found in the hardware bag Then install the blade screws to secure each blade to the fan IMPORTANT NOTE Follow the instr...

Страница 9: ...rs from the light kit to the connectors from the fan Connect the white wires together Connect the blue and black wires together Lift the light kit until its screw holes are aligned with the screw holes in the upper switch housing Make sure all the wires from the light kit are snug inside the center of the light kit not pinched in between the upper switch housing and the light kit or hanging out of...

Страница 10: ...chase the correct size and grade of battery most suitable for the intended use Replace all batteries of a set at the same time Clean the battery contacts and also those of the device prior to battery installation Ensure the batteries are installed correctly with regard to polarity and Remove batteries from equipment which is not to be used for an extended period of time Remove used batteries promp...

Страница 11: ... failure to follow Hunter instructions accidental damage caused by the fan owner or related parties modifications to the fan improper or incorrectly performed maintenance or repair improper voltage supply or power surge use of improper parts or accessories failure to provide maintenance to the fan or acts of God e g flood ORIGINAL PURCHASER S SOLE AND EXCLUSIVE REMEDY FOR A CLAIM OF ANY KIND WITH ...

Страница 12: ...emove standard downrod pipe Follow steps 6 10 to reassemble with new downrod 1 2 3 4 5 6 7 8 9 10 WARNING FAN FALL HAZARD To prevent SERIOUS INJURY or DEATH ALWAYS tighten setscrew with pliers DO NOT hand tighten setscrew CHECK the setscrew is tight using pliers each time you change fan direction ...

Отзывы: