8
®
41343-01 7/1/2002
STEP 2 - INSTALLING THE CEILING PLATE
4. Align the slotted holes in the ceil-
ing plate with the pilot holes in
the wood support structure.
Note:
The isolation pads should be flush
against the ceiling.
1. Drill two pilot holes into the wood
support structure through the
outermost holes on the outlet
box. The pilot holes should be
9/64" in diameter.
2. Thread the lead wires from the
outlet box through the hole in the
middle of the ceiling plate.
3. Your fan comes with two neo-
prene noise isolators. Position the
isolators between the ceiling plate
and ceiling by inserting the raised
areas on each isolator into the
holes in the ceiling plate. Refer to
Figure 2a.
Figure 2a - Adding Isolators to Ceiling
Plate
Figure 2b - Correct Position of Ceiling
Plate for Angle Mounting
Isolators
Ceiling
Plate
For Angle Mounting Only: Be sure
to orient the ceiling plate so that
the two hooks point up towards
the ceiling peak as shown in Fig-
ure 2b.
Note:
You will use the
hooks to support the fan during
STEP 4 - WIRING THE FAN.