PROJECT:

LOCATION:

SUBMITTED BY:

FAN MODEL

DOWNROD

WALL CONTROL

VARIABLE FREQUENCY DRIVE

I-BEAM MOUNTING HARDWARE

INSTALLATION

NOTES

Fan(s) will be located at the nearest location(s) as per building plans.
Wall control location(s) to be identified by owner at time of installation.
IF A TOUCHSCREEN IS SELECTED: Owner must provide 110V outlet within 6’ of touchscreen control location.
IF INSTALLATION IS TO BE PERFORMED BY OTHERS: Installation and site preparation to be performed by others at owner’s request.
IF GOLD LEVEL INSTALLATION: Basic mechanical installation includes: scissor lift rental (if necessary), mounting all fans and equipment, routing all 
communication cables, connecting fans and controls (if applicable) to power supply, and factory authorized startup and commissioning.
*CUSTOMER IS RESPONSIBLE FOR PROVIDING POWER SUPPLY TO 15’ FROM EACH FAN LOCATION PRIOR TO FAN INSTALLATION*
IF PLATINUM LEVEL INSTALLATION: Full turnkey installation includes: routing all electrical wire and conduit from each fan location to electrical
panel, terminating electrical connections with NEMA rated receptacles, scissor lift rental (if necessary), mounting all fans and equipment, routing all
communication cables, connecting fans and control (if applicable) to power supply, routing low voltage fire relay cable from each fan location to security
panel (if fire relay tie-in is required – Customer’s fire/security company to land final connections), and factory authorized startup and commissioning.

DIAMETER

COMMENTS

ECO

P: 629.333.7100  |  F: 615.232.3891  |  TOLL: 1.844.591.FANS (3267)

 

180 THREET INDUSTRIAL ROAD, SMYRNA 37167

  | 

HUNTERFAN.COM/INDUSTRIAL

24" Downrod Assembly

36" Downrod Assembly

48" Downrod Assembly

60" Downrod Assembly

72" Downrod Assembly

84" Downrod Assembly

96" Downrod Assembly

108" Downrod Assembly

120" Downrod Assembly

To Be Performed By Others

Gold Level Installation (Basic Mechanical)

Platinum Level Installation (Premium Turnkey)

8 '

10 '

12 '

14 '

16 '

18 '

20 '

24 '

AC 1PH 200-240V 60Hz

AC 3PH 200-240V 60Hz

AC 3PH 380-480V 60Hz

Содержание ECO 14

Страница 1: ...VEL INSTALLATION Full turnkey installation includes routing all electrical wire and conduit from each fan location to electrical panel terminating electrical connections with NEMA rated receptacles scissor lift rental if necessary mounting all fans and equipment routing all communication cables connecting fans and control if applicable to power supply routing low voltage fire relay cable from each...

Страница 2: ...CY MOUNTING SAFETY ECO 14 4 5 3 9 A 2 4 2 1 A 2 0 1 6 A Downrod length must be specified at time of order OPTIONAL INCLUDED CERTIFICATIONS ETL Intertek certified to ANSI UL 507 and CSA C22 2 No 113 in North America 10 year Non Prorated Warranty Fan I beam mount with pre wired downrod Control panel Install manual Mounting hardware kit Communication Kit Guy wire kit Additional cable lengths Glulam b...

Страница 3: ... equipment Many of the parts of this unit operate at line voltage DO NOT TOUCH any live conductors Install all covers before applying power or starting and stopping the unit To reduce the risk of electric shock or injury use this unit only in the manner intended by the manufacturer If you have questions call our Technical Department at 1 844 593 FANS 3267 Before servicing or cleaning the unit swit...

Страница 4: ...he maximum hanging weight of a 24 fan with a 10 downrod is 232 lbs If there is any uncertainty in the strength of the building structure a professional structural engineer should perform a thorough evaluation of the building prior to purchasing the fans Hunter Industrial Fan provides guidelines for mounting fans however it is the sole responsibility of the building owner and installer to ensure th...

Страница 5: ...NFORMATION ON PLACEMENT AND SPACING If possible avoid mounting fans directly below lights or skylights to avoid any strobe effect caused by moving airfoils Note a large fan 20 to 24 feet in diameter performs best at 20 to 30 feet above the floor but acceptable performance has been demonstrated as low as 10 feet and as high as 50 feet If the building has a mezzanine fans should be mounted so a pers...

Страница 6: ...ling to the fan s airfoils We recommend fan owners keep airfoils clean by having a maintenance person or skilled trade professional who has experience using a lift wipe the fan airfoils with a rag or sponge using hot water or regular cleaning solutions Please do not use chlorine or any chemicals containing chlorine RETENTION SYSTEM CHECK Each fan is installed with a retention system The retention ...

Страница 7: ...Beam Cl c c urnbuckles GUY WIRE KIT a a 2 S b b 2 Cl c c 4 Bolts Nuts Washers MOUNTING HARDWARE KIT FAN COMPONENTS a 1 Downr b 1 Motor 4 Motor Nu c 1 350 Series Contr d 1 Control Pan e 4 Blad a ECO Installation Manu b HMI installation and user gui MOUNTING HARDWARE KIT GUY WIRE KIT COMMUNICATON KIT INSTALLATION MANUALS ...

Страница 8: ...aisy chained to control up to 5 fans 3 5 LCD Touchscreen Alert Readouts Plug n Play design Standard junction box Simple flush mounting 2 73 69 31 2 00 50 80 3 95 100 31 3 05 77 44 3 55 90 14 0 203 4 places 5 16 2 06 52 26 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL CONTROL ...

Страница 9: ...ctly from screen Most cost effective network controller NUMBER OF FANS CONTROLLED ACTIVE DISPLAY AREA RESOLUTION DIMMING PROTECTION CLASS INPUT VOLTAGE UP TO 10 FANS 4 3 DIAGONALLY 480 X 272 DIAGONAL DIMMABLE TO 0 IP66 100 VAC 240 VAC 4 3 TOUCHSCREEN 430 SERIES TOUCHSCREEN CONTROLLER 4 30 109 31 5 88 149 31 UP TO 10 FANS 3 59 91 20 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUN...

Страница 10: ...cheduling grouping and fan naming Fan diagnostics directly from screen NUMBER OF FANS CONTROLLED ACTIVE DISPLAY AREA RESOLUTION DIMMING PROTECTION CLASS INPUT VOLTAGE UP TO 30 FANS 7 DIAGONALLY 480 X 272 DIAGONAL DIMMABLE TO 0 IP66 100 VAC 240 VAC 700 TOUCHSCREEN 5 18 131 60 7 69 195 20 4 04 102 70 CONTROL 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Страница 11: ...and BACnet IP IP67 BTL CE FCC CLASS B C PART 15 UL 60950 IC CANADA ROHS AND WEEE COMPLIANT PTCRB AND CTIA OPERATING ENVIRONMENT TEMPERATURE OPERATING ENVIRONMENT HUMIDITY INPUT VOLTAGE ENCLOSURE RATING CERTIFICATIONS 20 TO 70 C 4 TO 158 F 10 95 RH NON CONDENSING 24VAC 125MA 12 24VDC 250MA 12VDC BACNET GATEWAY 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Страница 12: ...802 3AB 802 3X FOR GIGABIT ETHERNET CE CSA EICC UL E200031 ROHS 2 COMPLIANT OPERATING ENVIRONMENT TEMPERATURE OPERATING ENVIRONMENT HUMIDITY INPUT VOLTAGE MAX POWER ENCLOSURE RATING CERTIFICATIONS 40 TO 75 C 40 TO 167 F 10 95 RH NON CONDENSING CLASS 2 POWER SUPPLY 12 48VDC 18 30VAC 50 60HZ BACNET GATEWAY OPTIONS FOR CONTROLS 12 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERF...

Страница 13: ...ELECTRICAL 13 ...

Страница 14: ...Connect a wire from terminal S to SB on the Fire Relay Terminal Strip Connect a wire from terminal C to C on the Fire Relay Terminal Strip Apply 12 40VDC from Fire Panel to Fire Relay Input Relay has a 20mA draw NORMALLY ENERGIZED On the Terminal Strip mounted to the outside of the VFD enclosure a Jumper will be in place on terminals S and C Remove the Jumper from terminals S and C Connect a wire ...

Страница 15: ...MAXIMUM Normally Energized Unenergized Dry Contacts VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure with Fire Relay Fire Panel 10 40VDC VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay Fire Panel Normally Closed 15 ...

Страница 16: ...16 ECO 14 3 14 ...

Отзывы: