10

1886

1886

Reverse 

Switch

Ceiling fans work in two directions: downdraft 
(counterclockwise rotation) and updraft 
(clockwise rotation). To change the direction 
of air flow, turn the fan off and let it come to a 
complete stop. The reversing switch is located 
inside the light fixture. It can only be accessed 
when the glass is removed. Slide the reversing 
switch to the opposite position. Restart the fan.

Updraft (clockwise rotation) 
creates a more indirect airflow. 
Updraft airflow is great for 
moving warm air downward.

Downdraft (counterclockwise 
rotation) creates a direct breeze 
and maximum cooling effect.

Controlling Your Fan

Troubleshooting

Cleaning the Fan

Use soft brushes or cloths to prevent scratching. 
Cleaning products may damage the finishes.

Hunter Pro Tip:

Fan Doesn’t Work

•  Make sure power switch is on.

•  Push the motor reversing switch firmly left or right to 

ensure that it is engaged.

•  Check the circuit breaker to ensure the power is 

turned on.

•  Make sure the blades spin freely.

•  Turn off power from the circuit breaker, then loosen 

the canopy and check all the connections according 

to the wiring diagram.

•  Check the plug connection in the switch housing.

Excessive Wobbling

•  Make sure the blades are properly installed on the 

blade iron posts.

•  Turn the power off, support the fan carefully, and 

check that the hanger ball is properly seated.

•  Use the provided balancing kit and instructions to 

balance the fan.

Noisy Operation

•  Make sure the blades are properly installed.

•  Check to see if any of the blades are cracked. If so, 

replace all of the blades.

Remote Control of Fan is Erratic

•  Make sure the battery is installed correctly.

•  Install a fresh battery.

Remote Only Works Close to Fan

•   Change battery.

Remote Pairing Issues

1.  To prevent faulty operation, please ensure all other 

ceiling fans within range are turned off at the wall 

switch while pairing.

2.  If you need to pair your remote, turn fan power off 

and back on at the wall switch. Within 3 minutes, 

press and release the “PAIR” button on the back of 

the remote. Do not hold down the button.

Multiple Remote Issues

•  If you have multiple remotes or multiple remote-

controlled fans installed on the same circuit breaker 

and you are experiencing interference or faulty 

operation of your remote controls, please go to 

 www.HunterFan.com/FAQs and click 

“How do I 

properly install multiple remote-controlled fans?”

 for 

information on how to correct this issue.

Содержание Apex II

Страница 1: ...Installation Manual 2019 Hunter Fan Co Model 50608 Matte Silver Fan weight 0 9 kg 2 lb 8 2 kg 18 1 lb Apex II PG3798 r112219 ...

Страница 2: ...lectrical shock or personal injury mount fan directly from building structure and or an outlet box marked acceptable for fan support of 31 8 kg 70 lb and use the mounting screws provided with the outlet box w 2 To avoid possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If ...

Страница 3: ...f hardware is needed to install each component x4 x2 x2 x2 x2 For installing the hanger bracket and wiring the fan For installing the blades For installing the canopy For installing the light fixture Bulb Switch Housing Plate Motor Light Kit Glass Blade Arm Blade Downrod Canopy Canopy Screw Blade Arm Screw Ceiling Bracket Wood Screw Wire Nut Washer bag Hunter Pro Tip Find a part that is missing or...

Страница 4: ...oor Support Structure Ceiling Outlet Box required Angled Mounting If you have a flat ceiling Hang your fan by a standard downrod Some fans come with a shorter downrod for a Low Profile installation Support Structure Ceiling Outlet Box required Standard Mounting A little more information on Angled Mounting For optimum performance and appearance a longer downrod should be used with your Hunter ceili...

Страница 5: ...ht Bulbs Glass Remote Cradle Remote WARNING To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location Installing the Secondary Hanging System OFF Turn Power Do this first NOTICE Do you have an exposed support structure Go to www HunterFan com FAQs and click Where do I connect the...

Страница 6: ...from the fan so that 8 inches remain coming from the top of the downrod Tighten the setscrew with pliers DO NOT HAND TIGHTEN KEEP 2 3 1 STEP STEP STEP Hunter Pro Tip The ground wire attached to the downrod is approximately 8 inches WARNING FAN FALL HAZARD To prevent SERIOUS INJURY or DEATH ALWAYS tighten setscrew with pliers DO NOT hand tighten setscrew CHECK the setscrew is tight using pliers eac...

Страница 7: ...r coming from the ceiling downrod hanging bracket and fan Connect the yellow wire from the receiver to the black wire from the fan Y e l l o w Connect the blue wire from the receiver to the blue wire from the fan Connect the white grounded wire from the ceiling to both the white wire from the receiver and the white wire from the fan White White Grounded Connect the black ungrounded wire from the c...

Страница 8: ...t the screw holes are aligned Insert the two canopy screws found in the hardware bag F i t t h e c a n o p y i n place as shown bag Canopy Screw Lightly attach the blade arms to the motor with screws found in the hardware bag then securely tighten after both screws are attached Repeat x5 IMPORTANT NOTE The blade arms should be mounted with the ridge facing downward Installing it incorrectly could ...

Страница 9: ...t counterclockwise Remove a pre installed assembly screw It does not matter which screw you choose Feed the 9 pin plug connector coming from the bottom of the motor housing through the center hole in the light kit assembly Connect it to the plug connector found in the switch housing area of the light kit assembly Make sure to line up the colored markings on the connectors WARNING FAN FALL HAZARD M...

Страница 10: ... IMPORTANT Always purchase the correct size and grade of battery most suitable for the intended use Replace all batteries of a set at the same time Clean the battery contacts and also those of the device prior to battery installation Ensure the batteries are installed correctly with regard to polarity and Remove batteries from equipment which is not to be used for an extended period of time Remove...

Страница 11: ... diagram Check the plug connection in the switch housing Excessive Wobbling Make sure the blades are properly installed on the blade iron posts Turn the power off support the fan carefully and check that the hanger ball is properly seated Use the provided balancing kit and instructions to balance the fan Noisy Operation Make sure the blades are properly installed Check to see if any of the blades ...

Страница 12: ...rranty does not cover any costs or fees associated with the labor including electrician s fees required to install remove or replace a fan or any fan parts There is no warranty for light bulbs except where otherwise noted remote control batteries fans purchased or installed outside the United States fans owned by someone other than the original purchaser fans for which proof of purchase has not be...

Отзывы: