How to unistall old tHermostat and install new Hunter tHermostat
44668 tHermostat
©2009 Hunter Fan Company
43091-01 • 03/20/2009
Note:
Make sure to bend your wires to one side so
you do not loose them in the wall.
4. Next, drill the holes in the wall using the marks you
made.
5. Insert the wall anchors and tap them into place
using the heel of your screwdriver or a hammer.
6. To mount the base, bring the wires through the
square hole in the base, and line up the wall
anchors with the slots in the base of the thermostat.
1. Remove the base from the Hunter thermostat by
pushing the button on the bottom and pulling both
pieces apart. Set the body of the thermostat aside.
2. To install the thermostat base, insert the wires
through the square hole in the back of the base.
Eyeball the base to the point it appears level. It does
not have to be exact.
3. Mark the place for the holes where the screws will
go.
iNsTalliNg youR
New huNTeR TheRmosTaT
2
7. Insert the screws and tighten with a phillips
head screw driver. Before tightening the screws
completely, ensure the thermostat base looks level
and firmly tighten the base to the wall.
warning:
Do not over tighten the screws into the wall
anchors.
8. For your convenience, we have included a red
jumper wire in the Accessory Pack. If your system
has “5 wires”, you will not need this jumper. If your
system has “4 wires”, as in this example, you will
need to install the jumper wire into the RH and RC1
terminals. Loosen, but do not remove, the terminal
screws and insert the jumper wire. Securely tighten
the screws of both terminals.