background image

3

42798-01

  •  09/16/09  •  Hunter Fan Company

1 • Getting Ready (continued)

7

’ Minimum 

Blades to Floor 

8

’ Minimum 

Ceiling Height

30” From 

Wall or 

Nearest 

Obstruction 

Step 1 - Choose the Fan Site

Proper ceiling fan location and attachment to the building structure 
are essential for safety, reliable operation, maximum efficiency, and 
energy savings. 

 

Choose a fan site where:

•  No object can come in contact with the rotating fan blades 

during normal operation.

•  The fan blades are at least 7 feet above the floor and the ceiling is 

at least 8 feet high.

•  The fan blades have no obstructions to airflow, such as walls or 

posts, within 30 inches of the fan blade tips.

•  The fan is directly below a joist or support brace that will hold the 

outlet box and the full weight of the fan.

Checklist for Existing Fan Site

If you want to use an existing fan site, complete the following checklist to 

determine if the site is acceptable and safe for your new Hunter fan. If you 

cannot check off every item, prepare a new fan site as described on this 

page.

Fan Support System

• 

Fan attaches directly to building structure.

• 

Fan support system will hold full weight of the fan and light kit.

Ceiling Hole

• 

The outlet box clearance hole is directly below the joist or support brace.

 

.

Outlet Box

• 

The outlet box is an UL-approved octagonal 4” x 1-1/2” outlet box (or as 

specified by the support brace manufacturer).

).

• 

The outlet box is secured to the joist or support brace by wood screws 

and washers through the inner holes of outlet box.

• 

The outer holes of the outlet box are aligned with joist or support brace.

• 

The bottom of the outlet box is recessed a minimum of 1/16” into ceiling.

Wiring

• 

The electrical cable is secured to outlet box by an approved connector.

• 

Six inches of lead wires extend from outlet box.

If your existing fan site is suitable, skip ahead to Section 

2 • Installing the 

Ceiling Plate. 

Suitable Existing Fan Site

Fan Support System 

Fan Support 

System 

Wiring 

Outlet Box 

Содержание 42798-01

Страница 1: ...ing and Hanging the Fan 7 4 Setting the Remote Transmitter and Receiver 9 5 Wiring the Fan 11 6 Installing the Ceiling Plate Cover 13 7 Assembling the Blades 14 8 Activating Auto BalanceTM 15 9 Comple...

Страница 2: ...l help you install operate and maintain your new fan These instructions are designed to make installation and assembly as simple and efficient as possible Each step has four components 1 Each step is...

Страница 3: ...ermine if the site is acceptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System Fan attaches directly to buildi...

Страница 4: ...utlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align with...

Страница 5: ...outlet box down through the hole in the middle of the ceiling mounting plate 2 CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit bre...

Страница 6: ...each other For Angled Ceilings Be sure to orient the ceiling mounting plate 2 so that the two tabs are pointing toward the ceiling peak Unbundle the wires from the fan Note Your Hunter fan comes with...

Страница 7: ...es from the fan through the pipe ball assembly 7 Use the Allen wrench 79 to securely retighten the setscrew 8 Raise the fan and align the slots in the ceiling mounting plate cover 3 with the hooks on...

Страница 8: ...Instructions Optional Pipe Ball Instructions 3 6 3 8 3 5 3 7 Pipe Ball Screw Ball Pipe Pipe Wedge Pin 3 Assembling and Hanging the Fan continued Your Hunter fan comes with an optional pipe ball assem...

Страница 9: ...n that order onto the long pipe ball assembly Go back to Step 3 2 IMPORTANT Before you change the DIP switch settings make sure the battery is not connected to the transmitter Remove the screw and gro...

Страница 10: ...included CFL bulbs Move the switch to the INC side if you are going to use incandescent bulbs Change the position of the DIP switches in the remote transmitter 87 and the receiver 86 Make sure that t...

Страница 11: ...table general use switch in accordance with national and local electrical codes To connect the wires hold the bare metal leads together and place a wire connector 70 over them then twist clockwise unt...

Страница 12: ...iling mounting plate 2 into the outlet box Position the receiver 86 in the ceiling mounting plate cover so that the antenna is close to the edge for clear reception WARNING Be sure no bare wire or wir...

Страница 13: ...nd grooves that must be aligned Holding the ceiling mounting plate cover 3 up with the screw holes aligned partially install two ceiling mounting plate cover screws 62 into the holes opposite the ceil...

Страница 14: ...ce Attach each blade 46 to a blade arm 98 using three blade assembly screws 67 The blades may appear slightly loose after screws are tightened This is normal Squeeze the rubber blade grommets 66 into...

Страница 15: ...d pipe ball assemblies it is now time for you to activate the Auto BalanceTM system by removing the five red retaining screws Rotate the blades slowly until one of the red retaining screws is visible...

Страница 16: ...hole slots Install the remaining screw into the housing Tighten all three screws firmly Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug butt...

Страница 17: ...ody to the lower plug connector in the lower switch housing assembly 31 Install the included Pin Based CFL bulb 259 26 Watt Maximum into the socket Install the included Pin Based CFL bulb 259 26 Watt...

Страница 18: ...finial 149 onto the threaded finial rod end until tight Removing the Light Fixture Disconnect the plug connectors between the black wire and the black wire with a white stripe Disconnect the plug con...

Страница 19: ...nector through the hole in the center of the lower switch housing Then pull out the small female connector Remove the light fixture bracket by removing the 2 screws attaching the bracket to the lower...

Страница 20: ...fan You can mount the remote holder to any toggle switch plate with the screws already in the switch plate Or you can simply mount the remote holder on the wall Removing the Light Fixture 9 15 Install...

Страница 21: ...ionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish If you need parts or service assistance please c...

Страница 22: ...f support fan very carefully and check that the hanger ball is properly seated If you have tried these troubleshooting solutions and still have trouble visit our Web site at http www hunterfan com Hun...

Отзывы: