background image

43

ICOnS AnD FEATUrES

1.  InDIGlO® night-light - will backlight the display for easy viewing 

in the dark. Press any button to illuminate the light.

 

  (If no button is pressed after 5 seconds, the backlight will turn off.)

note: If the thermostat shows a low Battery Warning, the backlight 

will not operate. Follow the instructions on pages 42-43 to change 

batteries.

2.  Filter change indicator - will flash after 400 hours of system use 

as a reminder to check or change your filter. Press and hold the 

F

ilTER

 button for 3 seconds after changing the filter to reset the 

filter timer. 

  (Pressing the Filter button for less than 3 seconds will cause the Filter 

change indicator icon to appear. The filter timer will not be affected 
unless the button is held for more than 3 seconds.)

note: Clearing the Filter counter will also clear the Energy counter. 

See pages 50-51 for more information. 

Содержание 42710-01

Страница 1: ...Form 42710 01 20091204 2009 Hunter Fan Co Set ave Set ave Set ave Installation and Operation Manual Model 44360 Programmable Thermostat English...

Страница 2: ...2...

Страница 3: ...Installing the Thermostat 12 Installing the Wall Plate 12 Connecting the Wires 16 Attaching the Thermostat 18 Settings 22 Methods of Operation 26 Manual Operation Override 28 Default Programs 32 Creat...

Страница 4: ...year round energy savings Please read this manual before beginning installation and save this booklet for complete operation instructions The Hunter Technical Support Group is available from 7 am to...

Страница 5: ...stems Oil Fired Boilers Oil Fired Furnace Electric Furnace Electric Air Conditioning Single Stage Heat Pumps This thermostat is not designed for multi stage heat pump systems or 110 220 V baseboard he...

Страница 6: ...crews and two wall anchors for mounting To install your new thermostat you will need the following supplies Flat head screwdriver Small Phillips head screwdriver Hammer Electric drill and 3 16 bit Two...

Страница 7: ...7 NOTICE Do not disconnect the wires from the existing thermostat before reading these instructions The wires must be labeled prior to removal to ensure proper reconnection Y RC G W w Y RC G W...

Страница 8: ...8 Y RC G W Y RC G W...

Страница 9: ...Remove the existing thermostat cover to access the wires from the wall Some thermostats may have multiple covers screws or other locking devices that must be removed or disengaged See page 8 for comm...

Страница 10: ...ting thermostat is marked label the wire with this sticker G F G G W H B W B W B Y C M O Y 0 Y 0 RC VC RC RC RH R VR 4 RH RH 24 Volt 24 Volt cool air conditioning compressor heating fan Y1 Y1 Y1 heat...

Страница 11: ...resent C may be a Common wire and should not be used If you have a wire marked C do not connect it to any terminal This wire is used only for non battery powered thermostats 5 Do not let the wires sli...

Страница 12: ...12 W B R C G Y 0 Y 1...

Страница 13: ...essing the release tab on the bottom of the thermostat 2 Position the new wall plate on the wall and pull the labeled wires through the opening 3 If the existing holes do not match those on the Hunter...

Страница 14: ...14 W R C Y G...

Страница 15: ...the wall Do not use plastic anchors if you encounter a stud in the wall 6 Reposition the wall plate on the wall pulling the wires through the opening Insert the mounting screws through the wall plate...

Страница 16: ...16 G RC RH Y 0W B R C G Y1 Y 0 W B Y 1 Terminal Shield...

Страница 17: ...his jumper If you do not have both an RH and RC wire leave the jumper in place 2 Match and connect the wires from the wall to the terminals as shown Wires should be inserted behind the black terminal...

Страница 18: ...18 DISABLE ENABLE RECOVERY HG HE W B Y O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AM HEAT 4 T Thermostat Cover System Switch Fan Switch...

Страница 19: ...fect when the system is set to cooling mode 2 Recovery Locate the Auto Recovery switch on the back of the thermostat If you wish to use the Auto Recovery feature verify that the switch is in the ENABL...

Страница 20: ...20 1 2 front cover Tab...

Страница 21: ...the bottom tab into place Note Do not force the thermostat onto the wall plate as the terminal pins may be damaged If the thermostat does not snap into place properly the unit may not work 5 Lift the...

Страница 22: ...22 reset...

Страница 23: ...RESET THE THERMOSTAT TO FACTORY DEFAULT PROGRAMS To change to Celsius C o 1 Press and hold the Up button 2 Use a paperclip to press the Reset button 3 Continue to press the Up button but release the R...

Страница 24: ...24 day time AM PM program...

Страница 25: ...ss Day Time AM PM and current hour will flash Press Up or Down to adjust the setting 2 Press Day Time again to adjust the minute setting Press Up or Down to adjust the setting 3 Press Day Time again t...

Страница 26: ...26 AM HEAT 4 T...

Страница 27: ...to 4 custom temperature settings per day or utilize pre programmed settings For manual operation override instructions see pages 28 35 To utilize the pre programmed settings see pages 36 37 To create...

Страница 28: ...28 AM HEAT 2 TH...

Страница 29: ...y override all settings and adjust temperatures manually If you want to only override the current program 1 Press and hold Up or Down for one second to enter Manual Override mode Release the button wh...

Страница 30: ...30 hold return system off heat cool HOLD...

Страница 31: ...old Return until the Hold icon appears 2 Press and hold Up or Down for one second to enter Manual Override mode Release the button when the display flashes 3 Press the Up or Down buttons to adjust the...

Страница 32: ...32 home today HOMETODAY...

Страница 33: ...at will then go back into Normal mode Pressing Home Today during the third program of the day will override the programs until the first program of the next day Press Home Today to enter or exit the p...

Страница 34: ...34 Set Temp...

Страница 35: ...those days The first day you set the Vacation Override feature will be counted as day one in your number of days The thermostat will resume your normal programs during program four the last day of th...

Страница 36: ...am 6 am Program 1 Heat 68o F 20o C Cool 78o F 26o C Program 2 Heat 60o F 16o C Cool 85o F 29o C Program 3 Heat 68o F 20o C Cool 78o F 26o C Program 4 Heat 60o F 16o C Cool 82o F 28oC 4 pm Default Prog...

Страница 37: ...MS By using the pre programmed settings this thermostat can save you money by optimizing energy usage in heating and cooling Refer to the Default Programs Chart for detailed information about the pre...

Страница 38: ...38 AM PM program hold return system off heat cool...

Страница 39: ...mal Display mode When setting each program time note the AM PM indicator Press Hold Return at any time to exit Program mode and save your settings During normal operation if no button is pressed for 5...

Страница 40: ...40 AM PM HEAT COOL 2 1 3 4 M T W TH F SA SU program hold return system off heat cool...

Страница 41: ...the next program number There are 4 programs per day If you do not wish to assign 4 programs per day set up to 4 keeping in mind that the total program time must equal 24 hours 6 Repeat steps 2 5 for...

Страница 42: ...42 filter FILTER...

Страница 43: ...to change batteries 2 Filter change indicator will flash after 400 hours of system use as a reminder to check or change your filter Press and hold the Filter button for 3 seconds after changing the f...

Страница 44: ...44 energy Usage Today Min Hr...

Страница 45: ...gy savings Press Energy to cycle through Today Yesterday This Week and Total up to 999 hours and 59 minutes Press and hold Energy until the display blinks to reset the counter Note Clearing the Energy...

Страница 46: ...46 HEAT COOL system off heat cool reset...

Страница 47: ...t or too slowly Press and hold both the Up and Down buttons until the word SPAN appears Use the Up or Down button to adjust the span setting Up will increase your cycle time by allowing the system to...

Страница 48: ...48 STAGE 1 PM COOL 4 M STAGE 2...

Страница 49: ...battery power shortage mode Stage 2 When insufficient battery power is left the battery icon will flash alone on the display and your system will turn off The display will be blank when no battery po...

Страница 50: ...50 hold return...

Страница 51: ...next program setting When the thermostat is in Auto Recovery mode the display will flash alternating messages of RECO and the time Auto Recovery can be disabled by sliding the recovery switch on the b...

Страница 52: ...52...

Страница 53: ...Reset and reprogram the thermostat after replacing the batteries if the thermostat has entered Error mode 9 Auto cut off automatically turns the system off if the temperature rises above 95 o F 35 o...

Страница 54: ...revent compressor damage due to rapid cycling 3 Resetting the unit To restore the thermostat to the original factory settings press the reset button with a paperclip This will erase any user programme...

Страница 55: ...at from the wall plate and set the HG HE switch to the correct position 3 My display is erratic 3 a Reset the thermostat and reprogram your settings 4 The program will not change at my desired setting...

Страница 56: ...he compressor 5 c Check the circuit breakers and switches to ensure there is power to the system 5 d Replace the batteries 5 e If applicable make sure the furnace blower door is closed properly 5 f If...

Страница 57: ...in the off position 7 a Replace unit 7 b Check your system for proper wiring 8 The LCD screen permanently reads HI LO or ERR 8 a Replace unit 9 How do I just operate my thermostat manually 9 a Manual...

Страница 58: ...s Visit http www hunterfan com for more information Can t I just call someone Sure The Hunter Technical Support Group is available from 7 am to 7 pm CST M F and 8 am to 5 pm Saturday They may be reach...

Отзывы: