 To avoid possible electrical shock, before installing your fan, 

disconnect the power by turning off the circuit breakers to the outlet box 
and associated wall switch location. If you cannot lock the circuit breakers 
in the off position, securely fasten a prominent warning device, such as a 
tag, to the service panel.

2-1.  Drill two pilot holes into the wood support structure through the 

outermost holes in the outlet box. The pilot holes should be 9/64” 
in diameter.

   

For Angled Ceilings:

 Be sure to orient the ceiling plate so that the 

two tabs are pointing toward the ceiling peak. 

2-2.  Your fan comes with four preinstalled noise isolators. Check to 

make sure all four isolators are in place and were not removed 
during shipment. 

2-3.  Place a flat washer on each of the two 3” wood screws. 
2-4.  Thread the supply wires from the outlet box in the ceiling through 

the hole in the center of the ceiling plate.

2-5.  Align the slotted holes in the ceiling plate with the pilot holes you 

drilled in the wood support structure. For proper alignment use 
slotted holes directly across from each other. 

   

Note:

 The isolators should be flush against the ceiling.

2-6.  Pass the screws through the slotted holes in the ceiling plate into 

the pilot holes you drilled. 

    Tighten the screws into the 9/64” pilot holes; do not use lubricants 

on the screws. Do not over tighten.

Flat Washer

3” Wood 

Screw

Steps 2-3 – 2-6

Ceiling 

Plate

For Angled Ceilings: 

Be sure to orient 

the ceiling plate so that the two tabs 
are pointing toward the ceiling peak. 

Toward 

Ceiling Peak

2 • Installing the Ceiling Plate

Содержание 42652-01

Страница 1: ...________________ Serial No ________________________ Date Purchased ____________________ Where Purchased _ _________________ For reference also attach your receipt or a copy of your receipt to the manu...

Страница 2: ...possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit break...

Страница 3: ...cluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans...

Страница 4: ...dder height dependent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the moto...

Страница 5: ...ll four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the...

Страница 6: ...embled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the set screw from the adapter 3 5 Place the low...

Страница 7: ...te and the green ground wire from the fan 4 4 Connect the white wire ungrounded from the ceiling to the white wire ungrounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring...

Страница 8: ...tall two canopy screws into the holes opposite the ceiling plate tabs 5 4 Partially install a canopy screw between the slots in the canopy When all the holes are properly aligned securely tighten all...

Страница 9: ...slightly loose after screws are tightened This is normal 6 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to s...

Страница 10: ...ten all three assembly screws could result in the switch housing fixture falling 7 4 To attach the lower switch housing connect the upper plug connector from the motor to the lower plug connector in t...

Страница 11: ...7 Raise the shade to the light fixture Tighten the thumbscrews securely 7 8 Install B10 candelabra base light bulbs 60 Watt maximum each Note Glass shade style and number of lights may vary Steps 7 7...

Страница 12: ...ir upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 8 4 For cleaning finishes use a soft brush or lint free cloth to preven...

Страница 13: ...ng bumpers Problem Noisy operation 1 Tighten the blade bracket screws until snug 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles wh...

Отзывы: