Step 5-2: Ball Hanging Version

CAUTION: 

Do not lift motor by wires.

A. 

Insert pipe nipple through canopy and feed wires from top 

of motor through pipe nipple. Screw pipe nipple into fan until 

tight (at least 4-1/2 turns). The setscrew locking the pipe nipple 

to motor must be tightened very securely. See Figure 5B. Failure 

to tighten screw could result in fan falling.

B. 

Before  hanging  the  fan  from  the  ceiling  plate  align  and 

engage  the  (2)  tabs  in  the  bottom  of  the  canopy  with  the  (2) 

grooves in the hanger ball. See Figure 5C.

Using the round hole in the top of the canopy, hang the fan from 

the hook in the ceiling plate. Make sure both tabs in the canopy 

remain engaged with the grooves in the ball. Be careful and don’t 

scratch the finish while hanging the fan. See Figure 5A.

Step 6: Install Remote Control

and Final Wiring

CAUTION: 

This device complies with part 13 of the FCC rules. 

Changes or modifications not expressly approved by Hunter Fan 

Company could void your authority to operate this equipment.
Operation is Subject to the Following Two Conditions:

(1) This device may not cause harmful interference.

(2)  This device must accept any interference received, including 

interference that may cause undesired operation.

NOTE: 

Use with a fan that incorporates an air gap switch (nor-

mal “ON-OFF” wall switch).

WARNING! 

Maximum fan load is 100 watts; maximum lamp is 

240 watts. Do not use any speed control with this product.

Figure 5B

LEAD WIRES

PIPE 

NIPPLE 

BALL

PIPE NIPPLE

MOTOR

SETSCREW

(TIGHTEN 

SECURELY)

CANOPY

Figure 5. Low Profile Version

Step 5-1: Fan Assembly

Low Profile Version

A. 

Place the canopy on top of the fan so the hole in the bottom 

of the canopy fits over the adaptor on the top of the fan. See 

Figure 5. Place the canopy assembly washer inside the canopy 

with the vertical flange of the washer resting on the inside of 

the canopy.

B. 

Position the (3) slots in the canopy assembly washer over 

the (3) threaded holes in the adaptor. See Figure 5.

C. 

Secure the canopy to the top of the fan using the (3) #8-32 

x 7/8 long screws with lock washers. Make certain all screws 

ae tight. Failure to do so could result in the fan falling.

CAUTION: 

To ensure proper engagement of the canopy assem-

bly screws, the canopy must fit snug against the top of the fan.

CAUTION: 

Do not lift motor by wires.

D. 

Being careful not to scratch the canopy finish, hang the fan 

from the hook in the ceiling plate using the round hole in the 

top of the canopy. See Figures 5 and 5A.

ASSEMBLY

WASHER

#8-32 SCREW

CANOPY

ROUND HOLE

ADAPTOR

TOP OF FAN

Figure 5A. Hanging the Fan

FAN

CEILING PLATE

HOOK

CANOPY

Figure 5C.  Aligning Tab & Groove

GROOVE IN

HANGER BALL

TAB IN BOTTOM

OF CANOPY

6” MIN.

Содержание 41597-01

Страница 1: ...is being installed keep the matched and balanced fan blades in sets as they were shipped Should one of the fan blades become damaged during shipment return all blades in the set for replacement C Chec...

Страница 2: ...ling plate to the 2 x 4 brace which supports the outlet box Use 2 10 wood screws 3 long and 2 flat washers for mounting Drill 2 pilot holes for the mounting screws 9 64 diameter See Figure 4A NOTE Whe...

Страница 3: ...sired operation NOTE Use with a fan that incorporates an air gap switch nor mal ON OFF wall switch WARNING Maximum fan load is 100 watts maximum lamp is 240 watts Do not use any speed control with thi...

Страница 4: ...Connect the larger black wire from the receiver to the black power wire Run the thin white antenna wire from the receiver through one of the slots in the ceiling plate and outside the canopy when inst...

Страница 5: ...crews provided in sack parts When properly assembled the end of the blade grommets will fit inside the bracket grommet Tighten the shoulder screws to prevent vibration and wobble when the fan is opera...

Страница 6: ...ons for control of the light for controlling the fan speeds for turning the fan off and for reversing See Figure 11 NOTE Be sure to install a fresh battery Check for weak battery if fan fails to opera...

Страница 7: ...all screws 4 Turn power off Support fan very carefully Loosen canopy and hang correctly Hunter fans have the power to cut your cooling costs up to 40 Beat the High Cost of Cooling e air movement creat...