Hunter 41597-01 Скачать руководство пользователя страница 1

41597-01   12/21/2002                                                                                                      1                                                                                       © 2002 Hunter Fan Company™

41597-01   12/21/2002                                                                                                      2                                                                                       © 2002 Hunter Fan Company™

CAUTION:

1.  Read entire instructions carefully before beginning installation.

2.  To avoid possible electrical shock, be certain electricity is shut 

off at main panel before wiring.

3.  All  wiring  must  be  in  accordance  with  national  and  local 

electrical codes. If you are unfamiliar with wiring, you should 

use a qualified electrician.

WARNING:

1.  To reduce the risk of fire or electrical shock, do not use a solid 

state speed control with this fan. Use Hunter Controls only.

2.  To reduce the risk of personal injury, do not bend the blade 

brackets when installing the brackets or cleaning the fan. Do 

not insert foreign objects in between rotating fan blades.

3.  To reduce the risk of personal injury, install the fan only to 

the building structure according to these instructions, and use 

only the hardware supplied.

Step 1: Pre-Installation Instructions

A. 

Select installation site. Check to see that in normal use no 

object  can  come  in  contact  with  the  rotating  fan  blades. The 

mounting site should also meet the precautions listed in Step 3 

below.

B. 

Installation hardware is included for a standard drywall or 

plaster ceiling. You will need a 4” x 1-1/2” or a 4” x 1/2” outlet 

box and wire nuts (2) which can be purchased from any hard-

ware store or electrical supply house.

C. 

The fan blades must be mounted at least 7’ above the floor. 

For maximum efficiency, they should not have any obstruction 

(walls, posts, etc.) within 24” of the blade tips. See Figure 1 for 

mounting distances.

Step 2: Inspection of Fan

A. 

Unpack the fan carefully to avoid any damage to the components.

B. 

Check  for  any  shipping  damage  to  the  motor  and  the  fan 

blades. If more than one fan is being installed, keep the matched 

and balanced fan blades in sets, as they were shipped. Should 

one of the fan blades become damaged during shipment, return 

all blades in the set for replacement.

C. 

Check contents to be certain it contains a bag of parts.

Step 3: Installation of Outlet Box and 

Rough-In Wiring

CAUTION: 

Your Hunter ceiling fan with accessories can weigh 

up to 35 lbs. The following precautions must be taken for safety 

and to ensure that your fan is securely mounted to the ceiling.

•  Be certain electricity is “off” at  fuse panel when inspecting or 

repairing installation site.

•  All wiring must meet local and national electrical codes.

•   Do  not  mount  directly  to  an  unsupported  ceiling  or  to  an 

electrical outlet box. Mounting must support a 35 lb. fan with 

accessories.

A. 

Secure metallic outlet box 4” x 1-1/2”  or 4” x 1/2” deep to 

2 x 4 cross brace between two ceiling joists as shown in Figure 

2. The  outlet  box  must  be  recessed  into  the  ceiling  by  1/16” 

minimum. Secure the outlet box to the cross brace by drilling (2) 

pilot holes no larger than the minor diameter of the wood screws 

(5/64”) and use two #8 x 1-1/2” wood screws and washers. Use 

the innermost holes for securing the box. Orient the box so the 

outermost holes will be used in Step 4B.

CAUTION: 

Do not use a lubricant on screws.

B. 

Bring electrical cable into the outlet box and attach with an 

approved connector. Make certain that wiring meets all national 

and local electrical codes. Wire leads should extend at least 6” 

beyond outlet box for ease in making connections. See Figure 3.

INSTALLATION INSTRUCTIONS

FOR HUNTER CEILING FANS TYPE 3

READ AND SAVE THESE INSTRUCTIONS

Figure 1.    Wall Clearances

FIGURE 2.    Outlet Box

2 X 4 BRACE

CEILING

OUTLET BOX

CEILING

JOIST

#8 WOOD SCREW & WASHER

(2) REQUIRED

FIGURE 3.    Wiring Outlet Box

CONNECTOR

6” MIN.

LEAD

LENGTH

8’ MIN.

CEILING

TO FLOOR

7’ MIN.

TO FLOOR

24”

CLEARANCE TO

OBSTRUCTIONS

®

Содержание 41597-01

Страница 1: ...is being installed keep the matched and balanced fan blades in sets as they were shipped Should one of the fan blades become damaged during shipment return all blades in the set for replacement C Chec...

Страница 2: ...ling plate to the 2 x 4 brace which supports the outlet box Use 2 10 wood screws 3 long and 2 flat washers for mounting Drill 2 pilot holes for the mounting screws 9 64 diameter See Figure 4A NOTE Whe...

Страница 3: ...sired operation NOTE Use with a fan that incorporates an air gap switch nor mal ON OFF wall switch WARNING Maximum fan load is 100 watts maximum lamp is 240 watts Do not use any speed control with thi...

Страница 4: ...Connect the larger black wire from the receiver to the black power wire Run the thin white antenna wire from the receiver through one of the slots in the ceiling plate and outside the canopy when inst...

Страница 5: ...crews provided in sack parts When properly assembled the end of the blade grommets will fit inside the bracket grommet Tighten the shoulder screws to prevent vibration and wobble when the fan is opera...

Страница 6: ...ons for control of the light for controlling the fan speeds for turning the fan off and for reversing See Figure 11 NOTE Be sure to install a fresh battery Check for weak battery if fan fails to opera...

Страница 7: ...all screws 4 Turn power off Support fan very carefully Loosen canopy and hang correctly Hunter fans have the power to cut your cooling costs up to 40 Beat the High Cost of Cooling e air movement creat...

Отзывы: