![Hunter Stoves Telford Inset 20DB CVWSTI08DBFM Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/hunter-stoves/telford-inset-20db-cvwsti08dbfm/telford-inset-20db-cvwsti08dbfm_instructions-for-installation-operating-maintenance-servicing_2186829012.webp)
12
JINTDBW09 Rev B 05/03/15
F
LUE
C
ONNECTION
N.B. An adjustable flue bend may be required for
some installations.
If connecting to a stainless liner,
a proprietary
single wall flue adaptor will be required. It is
recommended that a short length of flue pipe is
connected before the liner.
If connecting to an existing masonry
chimney it is
recommended that a flue forming pipe (short
length of flue pipe) is used and the void between
the flue forming pipe and the chimney is filled with
vermiculite concrete.
A suitable access hole will need to be made in the
chimney breast to allow the back filling to be
carried out and then filled and sealed once the
installation is complete.
Alternatively a connection can be made using a
register plate although it will be necessary to allow
access for fitting the flue pipe to the register plate,
infilling with vermiculite concrete and sealing all
joints.