Installation and Operating Instructions 

 
 
 
 
 
An  accredited  competent  person  must  carry  out  the  installation  of  this  appliance; 
alternatively,  your  local  Building  Control  Officer  can  approve  the  completed 
installation,  should  a  non-accredited  engineer  undertake  the  installation.  It  is  an 
offence,  under  UK  law,  not  to  comply  with  this  advice.  Please  hand  these 
instructions  to  the  stove  user  when  the  installation  is  complete.  Leave  the  system 
ready  for  operation  and  instruct  the  user  in  the  correct  use  of  the  appliance  and 
operation of controls.

 

 

 

Содержание Herald 8 CE V.11

Страница 1: ...ation and Operating Instructions An accredited competent person must carry out the installation of this appliance alternatively your local Building Control Officer can approve the completed installati...

Страница 2: ...O Emission at 13 O2 0 52 Mean Flue Gas Temperature 283 C Flue Gas Mass Flow 8 9 g s Ancit Total Efficiency 71 4 Nominal Heat Output 8 0 KW Output to Water 6 3 KW Output to Room 1 7 KW Mean CO Emission...

Страница 3: ...the stove to emit fumes into the room Flue Collar Place the Flue Gasket on the top or rear outlet as required Place the Flue Collar on top of the Gasket Secure to the four locating tabs inside the flu...

Страница 4: ...cal building control department must approve the installation Scheme Web address Telephone APHC Association of Plumbing and Heating Contractors Certification Limited www aphc co uk 02476 470 626 Build...

Страница 5: ...nd to prevent over firing If the reading is less than the recommended minimum then the performance of the appliance will be compromised Connection to the Chimney An existing fireplace opening can be b...

Страница 6: ...ll be installed on a floor with adequate load bearing capacity If the existing construction does not meet this prerequisite suitable measures e g load distributing plate should be taken to achieve it...

Страница 7: ...e stove Semi pumped systems should be used on heating and hot water systems with gravity circulation to the hot water cylinder and one unvalved 2 KW radiator to act as a heat leak when the central hea...

Страница 8: ...Circulating Pump Low Limit Thermostat 45 C Time Switch Drain Cock Injector Tee Wiring Diagram for general guidance only All electrical work must be carried out by a competent electrician in accordance...

Страница 9: ...st 24 hours On completion of the installation and commissioning ensure that the operating instructions and operating tools for the stove are left with the customer Ensure to advise the customer on the...

Страница 10: ...t clear from obstruction and blockage Air Controls Primary Air The thermostat at the rear of the stove controls the primary air The door sliders should be kept closed or the thermostat will not be abl...

Страница 11: ...rom front to back It should not be stacked above the bottom of the baffle as this may result in damage to the stove With a full load of fuel the stove will need to be refuelled approximately once ever...

Страница 12: ...he chimney draw so some practice may be necessary To revive the fire open the air controls until the fire is burning brightly de ash if necessary and refuel Set air controls as required Reduced Combus...

Страница 13: ...gly Never leave the stove unattended for long periods without first adjusting the controls to a safe setting careful air supply control should be exercised at all times WARNING FUME EMISSION Properly...

Страница 14: ...tances should be avoided as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming of the doors could crack the glass pa...

Страница 15: ...stove and the open fire Gaskets All gasket used on this appliance are produced from a heat resistant material called Manniglas Over time you may find that the gasket changes colour This is due to a r...

Страница 16: ...HHR08 046 Glass Clip Screw FSJM05008SS Door Glass HHR08 082 Glass Gasket HHR08 081 Right Hand Door HHR08 084 Door Slider HHR08 119 Slider Knob HHR08 045 Left Hand Door HHR08 079 Door Slider HHR08 119...

Страница 17: ...g Bar Upper HHR08 030 Flue Collar HHR08 023 Flue Cover HHR08 024 Primary Air Deflector Multifuel HHR08 088 Riddling Support HHR08 009 Catch Bar Drop in HHR08 083 Ashpan HHR08032 Side Brick HHR08 116 P...