background image

Appendix2: Set Controller IP by Tool 

 

A

Overview

 

HTA-830 Tool.exe is a program that automatically locates TCP/IP based controller as well 

as modify the device’s IP address. This program is application to TCP/IP device and does 

not require installation. Double click on the programs to execute. 

This program used broadcast search and connection method. And the terminal’s firewall 

should be shut down in order to locate the devices. 

 

B

Workspace Description

 

 

 

 

 

 Device List – Found devices are listed in this area. The following parameters are 

also included in the listing: 

HUNDURE                                                                 

16

                                 

 

 HTA-810/20 PE/PM Hardware manual 

 

z

  MAC ID (Media Access Control Identification): It serves as unique identifier of 

the device connected over the network. This fixed identification number is set 

from the factory and is not allowed to be modified. 

Содержание HTA-810PE

Страница 1: ...HTA 810PE PM HTA 820PE PM Time Attendance Recorder Hardware Manual Version 1 1 ...

Страница 2: ...oller Terminal Introduction 8 3 2 2 Siren Alarm Connection 9 3 2 3 RS232 RS485 Communication Port 9 3 2 3 1 RS485 Wiring Connection 10 3 2 3 2 RS 232 Wiring Connection 10 3 2 4 Power Supply Connection 11 Chapter 4 Installation Guide 12 Chapter 5 Testing 13 Chapter 6 Troubleshooting 14 Appendix 15 Appendix1 Error Message Codes 15 Appendix2 Set Controller IP by Tool 16 Revision History HUNDURE 1 HTA...

Страница 3: ... 1 Product Overview 1 1 Package Contents Controller x 1 Base x 1 Adaptor x 1 Option DC Jack Converter x 1 Hex key wrench x 1 Screw x 4 Cable x 1 Quick Start Guide x 1 HUNDURE 2 HTA 810 20 PE PM Hardware manual ...

Страница 4: ... 810 820 z Visual LED for display of time card number communication mode swiped card indication z 16 shift schedule for HTA 820 z 32 sets siren output z Auto scheduling for data collection time synchronization valid card download z Invalid re swiped cards off the record saves memory capacity z Memory full warning z At least 60 days data storage in case of power outage z RTC Real Time Clock ensures...

Страница 5: ...Format Range Bar Code Type Resolution 0 15mm Scanning Speed 100 1000mm sec Magnetic Type ISO3554 Standard Track 1 or 2 or 3 Scanning Speed 3 40ips 125 KHz EM Compatible 8 10 CM max 13 56 MHz MIFARE Compatible 5 CM max Power Input DC 12V 1A Current Consumption 250mA max Comm Interface RS 485 Comm Baud Rate 1 200 2 400 4 800 9 600 19 200 bps N 8 1 Operating Temp 10 C 55 C 14 F 131 F Relative Humidit...

Страница 6: ...Chapter 2 Physical Dimension 2 1 Dimension Scale mm HUNDURE 5 HTA 810 20 PE PM Hardware manual ...

Страница 7: ... 820 3 Communication LED Red LED blinks upon receipt of data from PC Green LED blinks upon trasmission of data to PC 4 Swipe Card Indication LED Green LED blinks upon swipe of valid card Red LED blinks when invalid card is swiped 5 Card Sensor Area 1 Card sensor Note 1 This area is card swiping slot for magnetic models HTA 810M HTA 820M or barcode models HTA 810B HTA820B HUNDURE 6 HTA 810 20 PE PM...

Страница 8: ...Chapter 3 System Configuration Wire Connections 3 1 System Configuration HUNDURE 7 HTA 810 20 PE PM Hardware manual ...

Страница 9: ... Terminal Introduction Description A DC 12V Input B Communication C Siren Relay Output COM D Siren Relay Output NO E Siren Relay Output NC z COM Common contact NC Norrmally closed NO Normally open HUNDURE 8 HTA 810 20 PE PM Hardware manual ...

Страница 10: ...3 2 2 Siren Alarm Connection 3 2 3 RS232 RS485 Communication Port 6 5 4 3 2 1 RS 485 GND RS 485 RS 232RX HUNDURE 9 HTA 810 20 PE PM Hardware manual RS 232TX NC N A COM N O N C ...

Страница 11: ...ote Assign different IDs for each HTA 810 820 recorder when there are more than one recorders in the network z Default ID is 1 z Set your ID with our software 3 2 3 2 RS 232 Wiring Connection HUNDURE 10 HTA 810 20 PE PM Hardware manual ...

Страница 12: ...3 2 4 Power Supply Connection Turn to the back side of HTA 810 820 and connect DC12V 1A power to the power jack connector HUNDURE 11 HTA 810 20 PE PM Hardware manual ...

Страница 13: ...wires in accordance with the wiring instruction below C Install the controller upper cover to the back base D Mask sure the back base and the controller upper cover guides are aligned E Using the hex key wrench fasten the screw onto the bottom of controller HUNDURE 12 HTA 810 20 PE PM Hardware manual ...

Страница 14: ...vice displays its firmware version Firmware Version 1 8 4 The device displays communication baud rate Baud Rate 9600 bps 5 The device displays Time for ready mode Ready Mode 6 When user swipes the card the device shows the last 4 digits of the card number HUNDURE 13 HTA 810 20 PE PM Hardware manual Swipe card displaying last 4 digits ...

Страница 15: ...heck the communication LED red LED blinks upon receipt of data from PC and green LED blinks upon transmission of data to PC Q There is no response after swiping cards A 1 Please check if the card is correct and compatible with the type of purchased HTA 810 820 2 Please make sure the card is encoded 3 Make sure the card is swiped over card sensor area 4 Make sure the right side of the card is used ...

Страница 16: ...id card area damage Bad2 Flash swiped card area damage Bad3 SRAM damage Bad4 Bad sector area damage Bad5 Flash erase fail EF Bad6 Flash fail Bad7 Flash fail When version is V3 03 afterward Kindly refer to follow figure Error Code Description Err0 Cannot save invalid card Err1 Re swipe of card within a limited time prohibited Err2 Card number contains non numeric character under compression mode Er...

Страница 17: ...sed broadcast search and connection method And the terminal s firewall should be shut down in order to locate the devices B Workspace Description Device List Found devices are listed in this area The following parameters are also included in the listing HUNDURE 16 HTA 810 20 PE PM Hardware manual z MAC ID Media Access Control Identification It serves as unique identifier of the device connected ov...

Страница 18: ...Button Click this button to search all the devices connected over the network New settings area Modifies device s IP address Submask Gateway Port and BaudRate Broadcast Setup This button will set new parameters to a device via broadcast method Connect Setup This button is connecting with a device and sets its new parameters C Operation Procedure C 1 Shut down firewall C 2 Double click HTA830Tools ...

Страница 19: ...kindly differentiate each using their MAC ID C 4 Select a device as shown below HUNDURE 18 HTA 810 20 PE PM Hardware manual C 5 Current settings of the selected device will be displayed in the New settings area To modify it overwrite the parameters ...

Страница 20: ...Port Default is 4660 or user defined port z BaudRate Definition by different devices Kindly inquire the necessary information about the network environment from your IT personnel All parameter settings should be the same with the system in order to establish connection with the devices HUNDURE 19 HTA 810 20 PE PM Hardware manual ...

Страница 21: ...up is applicable when devices are connected under the same network However if the program and device belong to different network or if connection cannot be established due to network barriers kindly use Connect Setup button to set the parameters HUNDURE 20 HTA 810 20 PE PM Hardware manual ...

Страница 22: ...al C 7 Upon completion of the settings the device will automatically restart and temporarily disconnects from the network Kindly wait for 10 20 sec before searching the device again Check if the parameters are correct and successfully modified ...

Страница 23: ... to improper operation or maintenance connection to improper equipment or attempted repair by anyone other than In no event shall manufacturer s liability exceed the price paid for the product from direct indirect special incidental or consequential damages resulting from the use of the product its accompanying software or it s documentation Hundure makes no warranty or representation expressed im...

Отзывы: