On/Off Touch Control
Pressure Gauge Mode
On/Off Touch Control
Ultrasonic Cleaning Mode
The ultrasonic cleaning ( ) is a default mode. The cleaning process takes 20
seconds per cycle and the countdown timer on the screen indicates the number of
seconds. During the cleaning cycle, mode switching is not allowed. Simply power-off
the device by touching the ( ) for 3 seconds to stop the cleaning cycle if needed.
Stylus Rubber Support
Water Basin
Scale Platform
The 3 types of stylus rubber
support provided are
designed to accommodate
with different types of
turntable cartridges. Insert
the rubber support properly
onto the water basin, place
the cartridge to test out the
compatibility, and select the
best fit
*1
.
Must insert the rubber support properly onto the
water basin, and then use the water dropper to
fill up the basin with water before starting the
ultrasonic cleaning mode.
Rest the cartridge gently on top of the
scale platform and place the stylus
aligned with the black dot indicated.
• DO NOT overload the scale platform
with anything ≥10 grams. Failing to
do so may cause damage or deform
the sensitivity of the device’s sensor.
• DO NOT measure anything except
the turntable cartridge.
The aluminium digital pressure gauge is used to determine the stylus tracking force.
• DO NOT operate the cleaning mode without
water in the water basin.
*1
The stylus cantilever should not be leaned against the stylus rubber support, and the stylus tip
should not be rested on the base of the water basin.
Correct Placement of the Stylus Rubber Support
Top
View
Bottom
View
No. 1
Type