Mark and Display Waypoints

Marking a Waypoint - Cursor Position (SOLIX)

Marking a Waypoint - Cursor Position (HELIX)

Содержание MEGA 360 IMAGING Series

Страница 1: ...Operations Guide 532731 1EN_A MEGA360 IMAGING...

Страница 2: ...only be performed by authorized service personnel Any modification of the serial number or attempt to repair the original equipment or accessories by unauthorized individuals will void the warranty N...

Страница 3: ...ust not be disposed of with other household refuse It must be disposed of and collected for recycling and recovery of waste EEE Johnson Outdoors Marine Electronics Inc will mark all EEE products in ac...

Страница 4: ...n 21 Start Pinging 21 Stop Pinging 23 Wet Switch 24 What s on the MEGA 360 Imaging Display 25 MEGA 360 Imaging Views 26 SOLIX Series Views 26 HELIX Series Views 27 360 View 27 360 Sonar Combo View 28...

Страница 5: ...speed travel Obstructions Be aware of obstructions in the water that could damage the transducer pod Powering Off When the boat is at dock or in storage the MEGA 360 Imaging transducer should be turn...

Страница 6: ...the MEGA 360 Imaging transducer scans the water with its razor thin high definition beams Visualize the MEGA 360 Imaging beams as a thin sonar wall extending 125 feet in every direction around your bo...

Страница 7: ...ud sand or descending terrain Light shades represent denser terrain timber rocks or rising terrain A very hard bottom may appear as white on the display White streaks or clouds may represent fish on t...

Страница 8: ...aging transducer first 3 Select Normal mode HELIX Series 1 Turn on the power source from the main switch 2 On the control head press the POWER key If you are powering on a control head in a multiple c...

Страница 9: ...e Settings Network System Info HELIX Series You can confirm the MEGA 360 connection by checking the Accessory Test view 1 Press and hold the VIEW key 2 Select System Accessory Test Confirm MEGA 360 is...

Страница 10: ...iption Detected and Active The compass heading sensor is on and heading data is being received Connected but not Detected or Active The compass is not detected on the network and not transmitting data...

Страница 11: ...GPS 2 select Signal Strength Signal Strength GPS 1 GPS 2 displays vertical bar graphs indicating the satellite signal strengths with the respecting CNO Carrier to Noise value 0 to 60 Signal Strength b...

Страница 12: ...PS Diagnostic View or Accessory Test Change the setting for each view to Visible Reviewing GPS Reception HELIX fixed type shown as enhanced monitored satellite signal strength gray active satellite si...

Страница 13: ...that you will receive the latest Humminbird news including accessory compatibility and software update information 1 Go to our Web site at humminbird com Select Support Register Your Product 2 Follow...

Страница 14: ...ation Save to the SD Card left slot SD Card 1 right slot SD Card 2 8 Repeat the steps in this section on each control head HELIX Series Export Navigation Data 1 Install the SD card or microSD card acc...

Страница 15: ...Power on your Humminbird control head Start Normal mode 7 Follow the on screen prompts to update the control head software 8 When the software update is complete remove the SD or microSD card from the...

Страница 16: ...p the System menu icon Google Android Tap the FishSmart main menu Select system 3 Tap Update next to the selected unit The download progress is displayed on the screen 4 Tap Transfer next to the selec...

Страница 17: ...E The MEGA 360 Imaging transducer can be connected in conjunction with HW HW MEGA DI HW MEGA DI MEGA SI transducers as well as built in MEGA DI and built in MEGA SI from a Minn Kota trolling motor NOT...

Страница 18: ...stem View is displayed on the screen you will only need to press the MENU key once to open the Main Menu 2 Select the Network tab 3 Select Network Source Setup Press the RIGHT Cursor key Opening the N...

Страница 19: ...e the Cursor Control key to select a tab and choose a source Press the CHECK INFO key to select the source as follows 2D Traditional Sonar Select the 2D tab and select a 2D sonar source for the tradit...

Страница 20: ...displaying a certain frequency from a transducer on the network NONE will be displayed in the beam frequency column in the Network Source Setup dialog box NOTE The availability of beams is determined...

Страница 21: ...t pinging from the 360 View or from the Menu System Start Pinging from a 360 View When a MEGA 360 Imaging transducer is connected to the control head the 360 View will be automatically added to the vi...

Страница 22: ...HECK key 1 With a 360 View or 360 Imaging Combo View displayed on the screen press the MENU key once 2 Select 360 Pinging and press the RIGHT Cursor key to select On Pinging from an X Press Menu SOLIX...

Страница 23: ...p pinging the MEGA 360 Imaging transducer when it is not in use Stop Pinging from the X Press Menu SOLIX Series HELIX Series 1 With the 360 View displayed on screen press the MENU key once or tap Sona...

Страница 24: ...ff 1 Press the POWER key 2 Select 360 Pinging and press the LEFT Cursor key to select Off Wet Switch The MEGA 360 wet switch automatically stops MEGA 360 pinging rotation while the transducer is out o...

Страница 25: ...oft bottom sand mud or descending terrain E Range is the 360 Range setting See Change the Sweep Speed and Range for more information F White streaks may indicate fish and a clouded area may indicate a...

Страница 26: ...The Views tool includes the complete database of available views for your control head Use the Views tool to create a new view and edit a view 1 Press the HOME key 2 Select the Views tool 3 Select a...

Страница 27: ...s a view instead of scrolling through the View Rotation 360 View The 360 View allows you to see the MEGA 360 Imaging data on the full screen 360 X Press Menu The X Press Menu allows you to start or st...

Страница 28: ...on the right Active Side SOLIX The selected pane is outlined in yellow Tap a pane or press the PANE key to select a pane HELIX The arrow points to the active side Press the MENU key once and select Ac...

Страница 29: ...ts to the active side Press the MENU key once and select Active Side from the X Press Menu Choose RIGHT or LEFT to set the active side X Press Menu After you set the Active Side press the MENU key onc...

Страница 30: ...GA 360 mode and Side Imaging mode Start Side Imaging SOLIX Tap the View widget icon in the side bar and select a Side Imaging view If you are switching from MEGA 360 mode to Side Imaging mode an on sc...

Страница 31: ...displayed When Contour Mode turned off the water column is displayed on the view The location of a target on the display is based on the slant range to the target When Contour Mode is turned on the b...

Страница 32: ...32 Display Settings MEGA 360 Sonar Options SOLIX...

Страница 33: ...is menu option to rotate the display and correct the alignment See the MEGA 360 Imaging Installation Guide for more information 360 Boat Icon Select On to display the boat icon or select Off to hide t...

Страница 34: ...reen press the MENU key once or tap Sonar 360 on the status bar 2 Select Sonar Colors 3 Tap a sonar color palette or use the Joystick to select a palette 4 Close Tap the X icon QUICK TIP This setting...

Страница 35: ...r greater depths increase the sensitivity to see weaker returns that may be of interest Contrast Adjust the Contrast setting to accent the light and dark parts of the MEGA 360 Imaging data to provide...

Страница 36: ...etimes present in murky or muddy water Contrast Accents the light and dark parts of the MEGA 360 Imaging data to provide greater definition When MEGA 360 Dynamic Contrast is turned on the contrast wil...

Страница 37: ...to a position on the 360 View 2 Close Press the EXIT key to remove the Cursor Zoom In Out SOLIX Series HELIX Series 1 Zoom In Tap the position twice double tap 2 Zoom Out Tap the screen with two finge...

Страница 38: ...Select 360 Speed 3 Press the RIGHT or LEFT Cursor keys to select a sweep speed Changing the Sweep Speed SOLIX Changing the Sweep Speed HELIX Change the 360 Range 360 Range controls how far the MEGA 3...

Страница 39: ...39 Sweep Speed and Range Adjusting the Range SOLIX Adjusting the Range HELIX...

Страница 40: ...ou to focus the sweep on a section of the water The sweep area can be set between 10 to 360 and you can adjust it as you prefer SOLIX Series HELIX Series 1 X Press Menu With a 360 View displayed on th...

Страница 41: ...the full 360 View SOLIX Series HELIX Series 1 X Press Menu With a 360 View displayed on the screen press the MENU key once or tap Sonar 360 on the status bar 2 Select Display Mode 3 Tap to select a d...

Страница 42: ...iew displayed on the screen press the MENU key once or tap Sonar 360 on the status bar 2 Select 360 Frequency Select and Display 3 Select a frequency from the list 1 Main Menu Press the MENU key twice...

Страница 43: ...360 is turned off you can mark waypoints but they won t be displayed on the 360 View NOTE The GPS Receiver Heading Sensor must be connected to the control head to enable these features on the 360 View...

Страница 44: ...44 Mark and Display Waypoints Marking a Waypoint Cursor Position SOLIX Marking a Waypoint Cursor Position HELIX...

Страница 45: ...er or battery switch NOTE Powering off the MEGA 360 Imaging transducer will be determined by the installation and power connection on your boat 3 Check the MEGA 360 Trolling Motor Bracket Confirm the...

Страница 46: ...d com Telephone 1 800 633 1468 Direct Shipping Humminbird Service Department 678 Humminbird Lane Eufaula AL 36027 USA Hours of Operation Monday Friday 8 00 a m to 4 30 p m Central Standard Time Social...