To change the area of the bottom being zoomed,
follow these steps:
1. Make sure the
L
EGEND
2000 S
ERIES
is operating in
B
TM
L
OCK
(Bottom
Lock) mode.
2. Push the
R
ANGE
knob. An adjustment indicator appears by the lower
zoom preview bar, indicating this is the selected depth limit for
adjustment.
Note: Pushing the R
ANGE
knob toggles between the upper and
lower zoom preview bar adjustment. If the lower zoom preview
bar is to be adjusted, push the R
ANGE
knob until it is selected.
3. Rotate the
R
ANGE
knob to adjust the zoom preview bar. Moving the zoom
preview bars closer together increases the display resolution in the
zoomed window; moving them further apart decreases display
resolution, but allows more area around the bottom to be viewed.
The indicators disappear after several seconds with
no adjustment. The
L
EGEND
2000 S
ERIES
continues to follow
the bottom using the new range. Any change made to
the zoom preview bars is remembered until the
L
EGEND
2000 S
ERIES
is powered off, when the unit defaults to
factory settings.
Manual Mode
M
ANUAL
mode turns off
automatic bottom tracking
,
leaving control of the depth range to the user. Both
the upper and lower depth ranges can be adjusted to
show the bottom, or any other desired depth, in
greater detail. When first switched to
M
ANUAL
mode, the
L
EGEND
2000 S
ERIES
defaults to the current automatic depth
range; however, after the manual depth ranges have
been set, the
L
EGEND
2000 S
ERIES
uses the new settings
until it is powered off, when it defaults to factory
settings.
M
ANUAL
mode works best in areas of relatively flat bottom
or if you are trolling slowly. It is also ideal for displaying
a small area of the overall depth range in great detail if
you are looking for fish at a specific depth.
To adjust the depth ranges manually, follow these
steps:
1. Make sure the Legend 2000 Series is operating in Manual mode.
2. Push the Range knob. An adjustment indicator appears at the
location of the Lower Depth Range, indicating that it is ready for
adjustment.
Note: Pushing the Range knob toggles between the upper and
lower depth range selection. If the Upper Depth Range is to be
adjusted, push the Range knob until it is highlighted.
3. Rotate the
R
ANGE
knob to adjust the Depth Range. Clockwise
rotation increases the depth; counterclockwise rotation decreases
the depth. The display updates as the changes are made.
After several seconds without pressing or turning the
knob, the
D
EPTH
R
ANGE
adjustment indicator will disappear
from the screen automatically. The
L
EGEND
2000 S
ERIES
does
not make adjustments to keep the bottom information on-
screen. If the depth is deeper or shallower than the ranges
on the display, the bottom contour will not be visible.
The manual range settings made to the
L
EGEND
2000 S
ERIES
default to factory settings after the unit is turned off.
Chart Speed
C
HART
S
PEED
selects the speed
at which the bottom
information moves across
the display. Options available range from 1 (very slow)
to 8 (very fast). Selecting a faster rate shows more
information in the
C
HART
W
INDOW
, but it moves across the
display very quickly. Selecting a slower rate keeps the
information on the display longer, but the chart
information becomes compressed and may be more
difficult to interpret. Setting
C
HART
S
PEED
in relation to
boat speed is often preferred.
The
C
HART
S
PEED
setting is retained in memory after the
L
EGEND
2000 S
ERIES
is turned off. The factory setting is
6
.
8
USING THE LEGEND 2000 SERIES
BOTTOM LOCK ZOOM MODE / MANUAL MODE
Manual Mode
Lower Depth Range
Adjustment Indicator
Upper Depth Range
Adjustment Indicator