background image

 
 

You should also note that it is possible to have the sensitivity set too high such that 

reflection off of suspended matter or air bubbles will begin to black out the display. 
 
 

In the manual mode the depth scale does not change automatically and the digital bottom 

depth is not displayed. To once again activate the automatic mode, depress the Sensitivity Auto 
"On/Off" switch. 
 
 

5. Audible Alarms: The LCR 3004 is equipped with two audible alarms, a Fish Alarm and 

a Bottom Alarm.  
 
Fish Alarm: 
 
 

The LCR Fish Alarm will give a short alarm sound anytime a return is detected between 

the boat and the bottom. It will not alarm on the bottom but only on objects off the bottom. 
 
 

To activate the Fish Alarm press the Fish Alarm "On/Off" button. The indicator "F" in the 

upper left of the screen will indicate that the Fish Alarm is on. The Fish Alarm is operational only 
while the LCR is in the automatic mode. See "Manual Mode" in this section for use of the alarm in 
the manual mode. 
 
 

The Fish Alarm may occasionally sound when no target is displayed. This can happen 

when a target is detected close to the bottom but is too close to be seen on the display. It can 
also happen when the display sweep speed is slow such that the target was detected but is gone 
by the time the display is updated. 
 
 

To turn the Fish Alarm off, simply press the Fish Alarm "On/Off" button again. Bottom 

Alarm 
 
 

The Bottom Alarm is activated by pushing the alarm "On/Off" button. When first activated, 

the alarm is set at five feet. The desired alarm depth can be adjusted up or down by pressing the 
depth set button and the increase * or decrease = button. When the increase or decrease button 
is pressed once, the alarm setting will change one division. If the button is held down the setting 
will move as long as the button is held down. The alarm setting is indicated down the right side of 
the display. The Bottom Alarm may be set anywhere from 4 feet to the maximum depth. When 
the bottom enters the alarm range it will trigger a continuous audible signal. 
 
 

The Bottom Alarm will operate both in the automatic and manual modes, however, the 

operation is slightly different depending on what mode is on. 
 
 

Automatic Mode: In the automatic mode a continuous alarm will sound only when the 

bottom depth is equal to or less than the alarm setting. Fish entering the alarm range will not 
trigger the alarm, unless of course the fish alarm is on. 
 
 

Manual Mode: In the Manual Mode either the bottom or fish can trigger the alarm. If the 

bottom depth becomes equal to or less than the alarm setting, a continuous alarm will sound. If a 
fish enters the alarm range a short, quick alarm will sound. Since the fish alarm is active only in 
the automatic mode, positioning the bottom alarm range close to the bottom will allow you to have 
a fish alarm in the manual mode. 
 
 

The alarm depth will adjust itself when the depth range changes from one range to 

another. Thus a depth alarm set at ten feet while on the 30 foot depth range will remain at ten feet 
deep should the unit advance to any other range. To set the alarm with the most accuracy, set it 
using the lowest depth range. 
 

Содержание LCR 3004

Страница 1: ......

Страница 2: ...uding aluminum Please carefully consider the following before installing your transducer TRANSDUCER MOUNTING OPTIONS A Transom Mount The Humminbird high speed transducer allows the transducer element...

Страница 3: ...bronz thru hull transducer has a threaded stem which installs through a hole drilled in the boat hull leaving the housing exposed under the boat This type of installation must be used for many boats...

Страница 4: ...use a silicone sealant between the screwhead and bracket in order to prevent leaking See Figure C Step 2 BRACKET INSTALLATION Fiberglass Boats If your boat has a stepped transom located below and und...

Страница 5: ...cally in the three slots found in the bracket It is important to use a silicone sealant between the screwhead and bracket in order to prevent leaking Step 3 TRANSDUCER PIVOT ASSEMBLY Assemble the pivo...

Страница 6: ...the bracket Slide the O ring on to the headed pin and insert it through the two parts Assemble by screwing the x3 8 allen head screw into the end of the pin and tighten See Figure G Step 5 ANGLE ALLIG...

Страница 7: ...h this type installation it is important that the transducer be mounted by someone familiar with the use of two part epoxy adhesives For this reason Techsonic Industries Inc will not be responsible fo...

Страница 8: ...ye of the transducer The bubbles will disappear in a short time or can be removed by rubbing the transducer eye with your fingers while the transducer is in the water 4 If your instrument should fail...

Страница 9: ...Install the mounting knobs and tighten snugly The unit can now be swiveled and tilted to any desired position...

Страница 10: ...cket can also be mounted directly to the dash without the swivel mount however this method is not recommended since the unit cannot be rotated INSTALLING THE CABLES Your LCR comes equipped with Hummin...

Страница 11: ...ole cover after determining the necessary wire length from the hole The power cable has a red lead to the positive post and the black lead to the negative post Install a 1 amp fuse between the red cab...

Страница 12: ...ft range the bottom depth must reach about 24 feet before the depth range will change to 60 feet You may also manually change the depth scale by pressing the depth set button Each time this button is...

Страница 13: ...d the unit will make a Chirping sound indicating a limit has been reached In the manual mode everything below the bottom is no longer blacked out therefore a second return or double echo can be displa...

Страница 14: ...e alarm is set at five feet The desired alarm depth can be adjusted up or down by pressing the depth set button and the increase or decrease button When the increase or decrease button is pressed once...

Страница 15: ...nit is in the automatic mode The Digital Bottom Reading will not be seen while in the manual mode Some additional things you should know about the LCR 3004 Some polarized glasses might effect your vie...

Страница 16: ...your electrical connections and fuse Also check that the red wire on the power cable is connected to the positive battery terminal and that the black wire is connected to the negative battery termina...

Страница 17: ...button to go back to the automatic mode Step 5 Press the alarm on off button to turn on the bottom alarm Next press the range down s button until the alarm setting is lower than the bottom reading A c...

Страница 18: ...ure and target returns These should help you in interpreting the information being displayed on your LCR Surface clutter The STC in your LCR will normally eliminate surface clutter however in some wat...

Страница 19: ......

Страница 20: ...Brush or thick standing timber will appear as a thick mass with holes or gaps as shown above...

Страница 21: ...herefore it will be displayed on the LCR as shown above To see the thermocline you will need to go to the manual mode and increase the sensitivity setting One of the best ways to learn to use your LCR...

Отзывы: