background image

1. Selecting Sensitivity/Units; 

Factory setting: +0/FEET 
 
The Sensitivity/Units function has two uses: It lets you 
adjust LCR 100 sensitivity and control whether depth 
measurement is in feet or meters. 
 
The LCR 100 automatically increases or decreases its 
sensitivity setting when water conditions change (as when 
the bottom is stirred up). If you want to manually adjust 
Sensitivity, select SENS and press the Up or Down arrow 
button to adjust the automatic setting within a "+5" to "-5" 
range. For example, if you set it at "+2," Sensitivity remains 
2 settings higher than the normal automatic setting. 
 
Pressing the ON-OFF button when the SENS menu is 
displayed switches the unit of depth measurement between 
feet and meters. 
 
 
 
 
 

2. Enabling Bottom Alarm; 

Factory .setting: OFF 
 
The Bottom Alarm lets you specify the minimum 
depth you want to maintain. To use it, select B ALM; 
then, press the ON-OFF button to activate the alarm, 
and the Up or Down arrow key to adjust the depth at 
which the alarm will sound. An alarm symbol is 
displayed when this function is on. 
 
When Bottom Alarm is on, you'll hear a continuous 
chirping sound when the bottom is shallower than you 
defined. This is very handy for alerting you to shallow 
water or helping you to maintain position over 
structure. 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Содержание LCR 100

Страница 1: ......

Страница 2: ...to electronic signals for display on the LCR 100 screen The LCR 100 uses the returned signals to display a detailed underwater image and constantly updates the display as you travel across the water...

Страница 3: ...udes a built in simulator that helps you learn to use your new equipment The simulator displays a typical underwater scene and lets you practice with the controls The unit must be turned off before yo...

Страница 4: ...functions for further adjustment Sensitivity Units Bottom Alarm Fish Alarm Zoom Bottom Lock Display Speed Depth Range To adjust any of these press SELECT until the function you want appears Each func...

Страница 5: ...remains 2 settings higher than the normal automatic setting Pressing the ON OFF button when the SENS menu is displayed switches the unit of depth measurement between feet and meters 2 Enabling Bottom...

Страница 6: ...To activate it select Zoom and press ON OFF The Zoom view initially begins at the surface pressing the Up or Down arrow adjusts Zoom depth The range of the display is shown when Zoom is on The Zoom ra...

Страница 7: ...is the last function selected you can use the ON OFF button to switch Bottom Lock on and off without having to press SELECT first 6 Setting Display Speed Factory setting One level below maximum The LC...

Страница 8: ...h water When cleaning the LCD screen use a chamois and non abrasive cleaner such as Windex Do not wipe while dirt or grit is on the screen Be careful to avoid scratching the screen The transducer face...

Страница 9: ...and high sensitivity The transducer is mounted too close to the propeller and is being affected by air bubbles from the prop Ask the dealer who installed the LCR 100 to move the transducer away from t...

Страница 10: ...rts 2 You will be charged for repair of any physical damage 3 Transportation charges will be the responsibility of the purchaser THIS IS A FULL WARRANTY AS DEFINED BY THE FEDERAL WARRANTY ACT EFFECTIV...

Страница 11: ...d it to us Refer to Humminbird s Guaranteed Service Policy at the end of this manual All units out of warranty will be returned C O D If you are including a check please attach it to the unit Techsoni...

Отзывы: