background image

141c Operations Manual

531442-1_B

141c Operations Manual

Содержание 141c

Страница 1: ...141c Operations Manual 531442 1_B 141c Operations Manual...

Страница 2: ...e should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may changetooquicklytoallowtimeforyoutoreact Alwaysoperatet...

Страница 3: ...ular Flasher View 11 Key Functions 12 POWER LIGHT Key 12 VIEW Key 12 MENU Key 13 4 WAY Cursor Control Key 13 EXIT Key 14 Powering Up the Unit 14 The Menu System 15 Start Up Options Menu 17 Normal Oper...

Страница 4: ...lter Advanced 32 Max Depth Advanced 32 Water Type Advanced 33 Alarms Menu Tab 34 Depth Alarm 35 Fish ID Alarm 35 Low Battery Alarm 36 Temp Alarm 36 Alarm Tone 37 Setup Menu Tab 38 Units Depth 39 Units...

Страница 5: ...t International only are only available on products sold outside of the US by our authorized International Distributors To obtain a list ofauthorizedInternationalDistributors pleasevisitourwebsiteatww...

Страница 6: ...t A sound wave can travel from the surface to a depth of 240 ft 70 m and back again in less than 1 4 of a second It is unlikely that your boat can outrun this sonar signal SONAR is an acronym for SOun...

Страница 7: ...eroutputistheamountofenergygeneratedby the sonar transmitter It is commonly measured using two methods Root Mean Square RMS measures power output over the entire transmit cycle PeaktoPeakmeasurespower...

Страница 8: ...Accessory Average Speed Average speed reading with Temp SpeedAccessory Second Sonar Return when the sonar signal bouncesbetweenthebottomandthesurfaceofthe water and back again Use the appearance of th...

Страница 9: ...pth BaitBall Fish the FishFinder displays fish as arches and orfishicons andcanbesettoalarmwhen a fish of a certain size is detected When a target is detected a Fish ID TM symbol appears on the displa...

Страница 10: ...splay cycles through the available views When the EXIT key is pressed the display cycles through the available views in reverse order Any view can be hidden or displayed as part of the view rotation u...

Страница 11: ...th range sufficient to show the bottom Depth Range is automatically selected to keep the bottom visible on the display although you can adjust it manually as well see Sonar X PressTM Menu Five additio...

Страница 12: ...appears on the right side of the display in the Sonar View only The RTS Window always updates at the fastest rate possible for depth conditions and shows only the returns from the bottom structure and...

Страница 13: ...s as a thinner line across the display A Soft Bottom such as mud or sand appears as a thicker line across the display Rocky Bottoms have a broken random appearance The sonar returns from the bottom st...

Страница 14: ...epresents weak returns in blue and strong returns in red WhiteLine highlights the strongest sonar returns in white resulting in a distinctive outline This has the benefit of clearly defining the botto...

Страница 15: ...ly to display a magnified image of the bottom The Zoom Preview Box shows where the zoomed view is in relation to the full range view The Zoom Level or magnification is displayed in the lowerleftcorner...

Страница 16: ...reset The digital readouts in the Big Digits View cannot be customized Circular Flasher View Circular Flasher View displays Real Time Sonar RTS data in the traditional flasher format Depth and temper...

Страница 17: ...he Light and Background menu Usethe4 WAYCursorkeytoselectLightorBackground and then use the LEFT or RIGHT Cursor key to change the settings Press EXIT to exit the Light and Background menu Press and h...

Страница 18: ...ng you to see the effects of your action immediately Reactivate the X PressTM Menu by using the UP or DOWN Cursor keys Main Menu Press the MENU key twice for the tabbed Main Menu System The Main MenuS...

Страница 19: ...e pressing EXIT will return to the previous level in the menu system Pressing EXIT will cycle through the available views in reverse order Powering Up the Unit Turn on your 100 Series Fishing System b...

Страница 20: ...al or Advanced User Mode Main Menu Tabs Less frequently adjusted menus are grouped into the Main MenuSystem TheMainMenusystemisorganizedunderthefollowingtabheadingsto help you find a specific menu ite...

Страница 21: ...hen you navigate to specific menus while in Advanced Mode Any changes made while in Advanced Mode will remain in effect after you switch back to Normal Mode See Setup Menu Tab User Mode for specific i...

Страница 22: ...tor System Status See the following paragraphs for more information about each of these choices Normal Operation Use Normal operation for on the water operation with a transducer connected In addition...

Страница 23: ...enefit of the Simulator it is important to select Simulator manually from the Start Up Options menu as opposed to letting the Fishing System enter Simulator automatically as it will if a transducer is...

Страница 24: ...ostic self test including unit serial number Printed Circuit Board PCB serial number software revision total hours of operation and the input voltage Accessory Test lists the accessories connected to...

Страница 25: ...frequently used Press the MENU key once while in any of the Sonar Views to access the Sonar X PressTM Menu NOTE UpperRangeonlyappearsinAdvancedUserModewhen in Sonar Split Sonar Big Digits and Circula...

Страница 26: ...sed sensitivity shows weaker returns that may be of interest Decreasing the sensitivity eliminates the clutter from the display that is sometimes present in murky or muddy water If Sensitivity is adju...

Страница 27: ...e Upper and Lower Range regardless of the manual settings entered To adjust the Upper Range 1 MakesureyouareinAdvancedMode thenhighlightUpperRangeontheSonar X PressTM Menu 2 Use the LEFT or RIGHT 4 WA...

Страница 28: ...al mode NOTE A minimum distance of 10 feet will be maintained between the Upper and Lower Range regardless of the manual settings entered To adjust the Lower Range 1 Highlight Lower Range on the Sonar...

Страница 29: ...o adjust the Chart Speed 1 Highlight Chart Speed on the Sonar X PressTM Menu 2 Use the LEFT or RIGHT 4 Way Cursor Control keys to increase or decrease the Chart Speed setting 1 9 Ultra where 1 Slow 9...

Страница 30: ...ows you to control how much of the water column measured up from the bottom is shown in the Sonar Zoom View Choose a small value to see low lying bottom structure or details of the bottom return Choos...

Страница 31: ...e MENU key twice to access the Main Menu SystemandthenpresstheRIGHTCursorkeytoselectthe Sonar tab NOTE Menu choices will vary depending on system settings such as whether the unit is set for Advanced...

Страница 32: ...shing System shows only the raw sonar returns on thedisplay Thesereturnswilloftenresultin arches formingonthedisplay indicating potential targets Due to the transducer beam angle the distance to a fis...

Страница 33: ...o change the Fish ID Sensitivity setting 1 Highlight Fish ID Sensitivity on the Sonar main menu 2 Use the LEFT or RIGHT 4 WAY Cursor Control keys to change the Fish ID Sensitivity setting Low 1 High 1...

Страница 34: ...isplay See Bottom Presentation for more information To adjust the Bottom View 1 Highlight Bottom View on the Sonar menu 2 Use the LEFT or RIGHT 4 Way Cursor Control keys to change the Bottom View sett...

Страница 35: ...turn Depth Lines On or Off The Depth Lines menu choice is available when User Mode is set to Advanced see Setup Menu Tab User Mode To change the Depth Lines setting 1 Make sure you are in Advanced Us...

Страница 36: ...ed The Surface Clutter menu choice is available when User Mode is set to Advanced see Setup Menu Tab User Mode To change the Surface Clutter setting 1 Make sure you are in Advanced User Mode then high...

Страница 37: ...ault Low Max Depth Advanced Max Depth adjusts the maximum depth of operation The performance of your FishingSystemcanbetunedtothemaximumdepthyouwillbefishinginbysettingthe Max Depth When a maximum dep...

Страница 38: ...nding on the type of fish you are seeking The salt water setting allows for a greater range in fish size adjustment to account for this Also make sure that the Water Type is set accurately especially...

Страница 39: ...s the Main Menu System The Alarms tab will be the default selection NOTE When an alarm is triggered you can silence it by pressing any key The alarm will be silenced and will not be triggered again un...

Страница 40: ...t OFF Fish ID Alarm FishIDAlarmsoundswhentheFishingSystemdetectsfish that correspond to the alarm setting Fish ID Alarm will only sound if Fish ID TM is on To change the Fish ID Alarm setting 1 Highli...

Страница 41: ...light Low Battery Alarm on the Alarms main menu 2 Use the LEFT or RIGHT 4 WAY Cursor Control keys to change the Low Battery Alarm setting Off 8 5V 13 5V Default Off Temp Alarm Temp Alarm sounds when t...

Страница 42: ...eproducedasyouadjusttheAlarmTonesothatyoucanselectthetonethatyoucanhearbest To change the Alarm Tone setting 1 Highlight Alarm Tone on the Alarms main menu 2 Use the LEFT or RIGHT 4 WAY Cursor Control...

Страница 43: ...uSystem thenpresstheRIGHTcursor key until the Setup tab is selected NOTE Menu choices will vary depending on system settings such as whether the unit is set for Advanced User mode whether it is an Int...

Страница 44: ...g 1 Highlight Units Temp on the Setup menu 2 Use the LEFT or RIGHT 4 WAY Cursor Control keys to change the Units Temp setting Celsius Fahrenheit Default Celsius Units Distance withTemp Speed Units Dis...

Страница 45: ...c models User Mode User Mode sets the menu system to either Normal or Advanced When set to Normal default setting only the basic menu options are shown When set to Advanced additional menu choices are...

Страница 46: ...ht Reset Triplog on the Setup menu 2 Use the RIGHT 4 WAY Cursor Control key to initiate Triplog Reset 3 TheConfirmdialogboxwillappear ToresettheTriplog presstheRIGHTCursor key once more To cancel Rese...

Страница 47: ...display status of these views can be changed only when in Advanced User Mode see Setup Menu Tab User Mode To Select Views 1 Make sure you are in Advanced User Mode then highlight Select Views on the S...

Страница 48: ...ed off displaying nothing in that area you can access this menu choice only when in Advanced User Mode see Setup Menu Tab User Mode Data windows can display readouts from supported accessories such as...

Страница 49: ...th Offset setting 1 Make sure you are in Advanced User Mode then highlight Depth Offset on the Setup menu 2 UsetheLEFTorRIGHT4 WAYCursorControlkeystochangetheDepthOffsetsetting 10 0to 10 0feetor 3to3m...

Страница 50: ...Accessory is connected and the paddlewheel has moved at leastonce whentheunitisinAdvancedUserMode seeSetupMenuTab UserMode To change the Speed Calibration setting 1 MakesureyouareinAdvancedUserMode t...

Страница 51: ...ng corrosion from the battery terminals or wiring or actually replacing the battery if necessary 100 Series Defaults to Simulator with a Transducer Attached A connected and functioning transducer will...

Страница 52: ...ed A mix of air and water flowing around the transducer cavitation may be interfering with the inter pretation of sonar data See your Installation Guide for suggestions on adjusting the transducer pos...

Страница 53: ...pears Todeterminewhethertheboat sengineisthesource of the noise increase the RPMs while the boat is in neutral and stationary to see if the noise increases proportionately if noise appears when you re...

Страница 54: ...ower Requirement 10 20 VDC LCD Matrix 320 V x 240 H Transducer XHS 9 20 T Transducer Cable Length 20 ft 6 m Current Draw 0 383 Amps NOTE Humminbird verifies maximum stated depth in saltwater condition...

Страница 55: ...ur Bottom Black is preferred by some anglers because of its high contrast and easy readability even though it can obscure bottom hardness information Bottom Contour Bottom Contour is the profile of th...

Страница 56: ...mforFilmSuper TwistNematic FSTNisamonochrome display technology characterized by black high contrast pixels All monochrome fixed mount Humminbird products use FSTN technology DualBeam PLUS DualBeam PL...

Страница 57: ...ignal on the display and is a very intuitive method of presenting information Traditionally the strongest sonar signals are represented in black and progressively weaker signals are represented in pro...

Страница 58: ...and is generally related to boat speed so that faster operation results in more noise Hydrodynamic noise can be overcome by proper transducer installation Many Humminbird products have a Noise Filter...

Страница 59: ...onfiguration for downlooking and also adds two additional beams to look to the left and right The sonar beams pointing to the left and right provide the ability to spot fish and structure over a wide...

Страница 60: ...r Distance can be determined because the speed of sound in water is constant and the time for the signal to return is measured Sound also travels very quickly underwater making sonar a responsive cost...

Страница 61: ...ltwater environments have significantly greater surface clutter than freshwater due to continuous wind and wave action that causes aeration at the surface The Surface Clutter menuprovidesmanualcontrol...

Страница 62: ...r are matched parts of the sonar system that send transmit and listen to receive the sonar signals and work in conjunction with the transducer Humminbird transmitters have an extremely fast cycling de...

Страница 63: ...nly used menu selections available with one press of the MENU key Items that appear on the X Press Menu are related to the current view and present the most logical choices for that view Zoom Zoom is...

Страница 64: ...59 Notes...

Страница 65: ...60 Notes...

Страница 66: ...ys By Telephone Monday Friday 8 00 a m to 4 30 p m Central Standard Time 1 800 633 1468 By e mail typically we respond to your e mail within three business days cservice johnsonoutdoors com For direct...

Отзывы: