Humless CampPower SIM-700 Скачать руководство пользователя страница 2

NOTICES

 Humless Rolling Power

 reserves the right to modify or change parts of, 

or all the specifications and pricing policies at company’s sole discretion.

 Humless Rolling Power shall not be liable for losses caused by either 

incidental or consequential use in connection with the furnishing, use or 
performance of this manual as well as any information contained herein.

 This document may not be copied or edited without Humless Rolling 

Power’s prior written approval.

CONTACT US

If you have any problems or need help when using our products,  
please contact Humless Rolling Power, your local distributor, or visit  

www.HumlessRollingPower.com   •  +1.866.476.2586

©2018 Humless Rolling Power, LLC. All Rights Reserved.

Publication Number:

 

SIM700-001

The information provided in this documentation contains general descriptions and/
or technical characteristics of the performance of the products contained herein. This 
documentation is not intended as a substitute for and is not to be used for determining 
suitability or reliability of the products for specific user applications. It is the duty of any such 
user or integrator to perform the appropriate and complete risk analysis, evaluation and 
testing of the products with respect to the relevant specific application or use thereof. Neither 
Humless Rolling Power nor any of its affiliates or subsidiaries shall be responsible or liable for 
misuse of the information contained herein.

i

Содержание CampPower SIM-700

Страница 1: ...ATTENTION Please follow the instructions in this user manual and pay close attention to all warnings Please DO NOT operate before reading this USER MANUAL USER MANUAL SIM 700 PORTABLE INVERTER...

Страница 2: ...ww HumlessRollingPower com 1 866 476 2586 2018 Humless Rolling Power LLC All Rights Reserved Publication Number SIM700 001 The information provided in this documentation contains general descriptions...

Страница 3: ...uct Installation Connection Steps 2 2 2 Precautions 3 2 3 AC Priority Mode 4 2 4 AC Shore Power Generator Power Cut Off 4 2 5 No AC or Solar Input 4 2 6 PV Solar Priority Mode 4 3 PRODUCT PANEL DISPLA...

Страница 4: ...ructions for the Camp Power SIM 700 The SIM 700 is a smart portable home and camping inverter This inverter has pure sine wave output with exceptional compatibility which can be connected to refrigera...

Страница 5: ...ventilation may be required for the unit to function 6 When cleaning always turn the power off Use a clean dry cloth and do not use liquids to clean this product 7 In the event of electrical fire use...

Страница 6: ...ck Always place in a dry location 3 ATTENTION Device may become warm to the touch when in use Ensure there is adequate ventilation around unit and keep away from flammable materials Keep unit dry at a...

Страница 7: ...or Solar Input The system will use battery storage to supply loads and AC power supply 2 6 PV Solar Priority Mode 1 During the day with ample sunlight and with the AC switch on the solar MPPT control...

Страница 8: ...om Red LED Means abnormal state light means solar part abnormal 4 ON OFF INSTRUCTIONS 4 1 AC Priority 1 Turn On Hold on off for 3 second to power unit on When the AC Power Switch is on inverter will w...

Страница 9: ...ep 2 Please ensure the PV solar panel is properly connected positive negative and voltage parameters consistent with the product identification and then turn on the solar input switch Step 3 Press the...

Страница 10: ...cuts off output Battery over voltage short circuit high temperature AC Grid power input is over voltage AC Grid power input is low voltage Loading exceeds device s rated power Loading bar showing the...

Страница 11: ...after 5S Low voltage alarm will beep 1 time 1S and flash battery last grid 1 time 1S and display overload grid High load alarm will beep before shutdown Inverter mode 80 t n e r r u c e g r a h C d a...

Страница 12: ...nverter mode 80 y c n e u q e r f t u p t u O Wave form distortion 4Ms typical value Max 6 Ms Efficiency Inverter overload 110 130 shutdown at 30s 130 150 shutdown at 3s Inverter output t i u c r i c...

Страница 13: ...10 10 NOTES...

Страница 14: ...11...

Страница 15: ...12 12...

Страница 16: ...2018 Humless Rolling Power LLC All Rights Reserved 1374 West 200 South Lindon UT 84042 www HumlessRollingPower com 083118...

Отзывы: