![Humboldt HS-5001EZ Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/humboldt/hs-5001ez/hs-5001ez_product-manual_2183648036.webp)
29
4 Menus
4.1 Data Menus
The Data function key
F1
accessible from the main menu. This key will
allow the users to view current measurement calculated results, standard or
statistical counts, setup a project for the measurement data and saving the
measurement data.
4.1.1 View Current Measurement
Where MDEPTH (measured depth) represent the depth at which the density
counts (DC) and the moisture count (MC) were taken. Subsequently the dry
density (in the soil mode measurement), wet density, moisture (in the soil
mode measurement), moisture percent, percent Proctor (in the soil mode
measurement), void ratio, percent air void, percent Marshall (in the asphalt
mode measurement) were calculate at that depth.
4.1.2 Current Standard / Statistical Counts
*DATA 06/06/98
*SETUP 4:00:00
*ENGINEERING
DEPTH=SAF
*DATA 06/06/98
*SETUP 4:00:00
*ENGINEERING
DEPTH=SAF
*CURRENT MEASUREMENT
*STD / STAT
*PROJECTS
*SAVE DATA
DD= XXXX.X M = XX.X
WD= XXXX.X %M = XX.X
% PR= XXX.X MAXD = XXX.X
* NEXT
MDEPTH = BAC
DC = XXXX.X DS = XXXX.X
MC = XXX.X MS = XXX.X
VR = XXX.X % AV = XXX.X
LAST
MDEPTH = BAC
Содержание HS-5001EZ
Страница 1: ...product manual HS 5001EZ_MAN_08 12 HS 5001EZ Moisture Density Gauge ...
Страница 2: ......
Страница 7: ...8 6 Reporting of Loss or Incident 61 8 7 Radiation Profile 61 9 Warranty 63 9 Warranty 93 ...
Страница 17: ...6 10 ...
Страница 71: ...64 ...