020-9905 User Manual Q3 (Advanced 3 year old child) Rev G Page 39 of 82
© 2016 Humanetics Innovative Solutions
Instrumentation
Load Cell
A Humanetics IF-217 or IF-218 6-Axis Load cell may be mounted between the lumbar
spine and pelvis.
1.
To do so, first remove the upper torso from the lumbar spine by removing the two
M6x43 screws.
2.
Then unscrew the four M5x12 counter-sunk head screws attaching the structural
replacement to the pelvis. Remove the lumbar spine/structural replacement assembly
from the pelvis casting.
3.
Unscrew the four M5x12 screws to remove the structural replacement from the lumbar
spine.
4.
Attach the load cell to the lumbar spine using four M5 x 12 SHCS.
5.
Mount the assembly onto the pelvis casting using four M5x12 counter sunk screws.
4.6 Pelvis
Construction
The pelvis casting is a single metal casting which fits into the pelvis flesh. The two items
are completely separable. The upper legs, with the ball and socket hip joint assemblies,
fit into the two openings at the left and right side of the pelvis.
The parts of the pelvis are listed below (see also Figure 18.)
Table 12.
Pelvis assembly parts
Description
Part No.
Qty. in Assembly
Pelvis assembly
020-7011
1
Pelvis casting machined
020-7001
1
Pelvis Flesh
020-7010
1
Hip joint lower
020-7201
2
Hip joint upper
020-7202
2
Hip joint spacer
020-7203
2
Screw SHCS M5 x 12
5000005
4
Screw BHCS M4 x 12
5000005
4