background image

 

 

 

Precautions 

  Do Not 

1.  This product uses ordinary off-the-shelf electronic components, and is therefore inappropriate for use in 

applications that require special quality or reliability and are expected to protect human lives or prevent 

accidents, such as safety mechanisms in fields including space, aeronautics, medicine, and nuclear 

power. 

2.  Do not be used underwater or in high-humidity environments. 

3.  Do not be used in the presence of corrosive gases, combustible gases, or other flammable gases. 

4.  Do not turn on power when circuit board surface is in contact with other metal. 

5.  Do not apply voltage higher than rated voltage. 

 

Attention

 

6.  This manual may be revised in the future without notice owing to improvements. 

7.  All efforts have been made to produce the best manual possible, but if users notice an error or other 

problem, we ask that they notify us. 

8.  Item 7 notwithstanding, HuMANDATA cannot be held liable for the consequences arising from use of 

this product. 

9.  HuMANDATA cannot be held liable for consequences arising from using this product in a way different 

from the uses described herein, or from uses not shown herein. 

10.  This manual, circuit diagrams, sample circuits, and other content may not be copied, reproduced, or 

distributed without permission. 

11.  If the product emits smoke, catches fire, or becomes unusually hot, cut the power immediately. 

12.  Be careful of static electricity. 

13.  This product may be subject to the export restrictions of Japan, the United States, or other countries. 

Purchasers are responsible for properly observing export restrictions. 

14.  HuMANDATA firmly refuses to export (including reexporting) products to countries or regions subject to 

export restrictions. 

Product Warranty and Scope of Support 

1. 

HuMANDATA guarantees that its products can be assembled as shown in published circuit diagrams and other design documents. 

There may be differences between actual components or their prescribed quantities and model numbers and those shown in circuit 

diagrams. 

2. 

Except for the guarantee in item 1, above, no guarantees whatsoever are made. When assembling the product as shown in a circuit 

diagram is impossible, and the problem can be solved by revising the diagram, HuMANDATA will revise the diagram. When a 

problem can be solved only by replacing components or modifying the product, HuMANDATA will take back the product to replace it 

with a properly functioning product. 

3. 

If the problem is minor, HuMANDATA will sometimes describe how to make the revision or modification, and ask the customer to 

solve the problem. 

4. 

HuMANDATA will determine how to honor the warranty, as through repair, replacement, return, or other action. The customer cannot 

specify what action to take. 

5. 

FPGAs and other components used in products sometimes have characteristic defects. Returns and replacements are not possible 

even if such defects are discovered, whether before or after purchase. 

6. 

HuMANDATA shall not be obligated to inform customers about defects in the main components used in products. 

7. 

HuMANDATA shall not be obligated to provide support for products, or to provide support for the software of other companies 

needed to use HuMANDATA products. 

8. 

Published documentation shall be limited to that published by HuMANDATA at the time of product purchase, and HuMANDATA shall 

not be obligated to provide any other documentation. 

9. 

When repairs or replacements are provided under warranty in Japan, purchaser shall pay shipping charges for  shipping to 

HuMANDATA, and HuMANDATA shall pay shipping charges for shipping to purchaser. 

10.  When shipping from outside of Japan, purchaser shall pay all expenses including shipping charges and taxes. 

11.  Under whatever circumstances, HuMANDATA shall provide support for its products for a maximum of one year after shipping from 

factory. 

12.  The Warranty is not applicable and support ends in the event of fire, storm and flood damage, earthquakes, lightning strikes, and 

other natural disasters, as well as conflict or other occurrences. 

13.  Purchaser is assumed to have read and understood all the above when purchasing a HuMANDATA product. 

Limitation of Liability 

1. 

Purchasers assume all liability associated with the use of this product. 

2. 

HuMANDATA assumes no liability whatsoever for any direct, indirect, special, incidental, or consequential damages arising from the 

use of this product, even if HuMANDATA has been advised of the possibility of such damage, whether legal or in tort. 

3. 

At the time this product is purchased, items 1 and 2 above shall be deemed to have been confirmed by purchaser. 

Trademarks and Other Considerations 

1. 

This manual uses various companies’ trademarks in places. 

2. 

HuMANDATA is this company’s registered trademark. 

HuMANDATA’s Philosophy 

1. 

HuMANDATA endeavors to raise product quality. We continually make detailed improvements and adjustments that are not shown 

in circuit diagrams. 

2. 

HuMANDATA actively publishes, on the Web and in other ways, information considered useful to customers. Examples would be 

how to use FPGAs and how to use development tools. 

3. 

HuMANDATA makes efforts for the long-term provision of products and for continuing their long-term support. 

4. 

Instead of concealing small product problems and documentation errors, HuMANDATA makes them public 

5. 

HuMANDATA abides by Japanese law and its spirit. We make no transactions with purchasers who commit illegal acts. 

 

Содержание ZKB-078KIT

Страница 1: ...HuMANDATA LTD Pitch Conversion Board Type 2 for ACM XCM 1 Series ZKB 078KIT User s Manual Ver 1 0 ...

Страница 2: ...Table of Contents Revision History 1 Introduction 1 1 Specifications 1 2 Name of Parts 2 3 SMA Connector 2 4 Additional Documentation and User Support 2 ...

Страница 3: ... to honor the warranty as through repair replacement return or other action The customer cannot specify what action to take 5 FPGAs and other components used in products sometimes have characteristic defects Returns and replacements are not possible even if such defects are discovered whether before or after purchase 6 HuMANDATA shall not be obligated to inform customers about defects in the main ...

Страница 4: ...ectors are available for the boards which have fast serial interface 1 Specifications Model Name ZKB 078KIT Dimensions 3 386 x 2 126 86 x 54 mm Weight 17 g typ PCB 4 Layer FR 4 t1 6 mm Immersion gold 80 pin Connector FX10A 80S 8 SV 71 Hirose x 2 Accessories DIL 80 pin headers x 2 Short resister J1 4C x 1 Niobium Oxide Capacitor NOJC336M010RWJ x 2 Screw x 8 Spacer x 4 RoHS Compliance YES There may ...

Страница 5: ...e by the order number below Order Number 8 SMA089PE8D 4 Additional Documentation and User Support The following documents and other supports are available at http www hdl co jp en spc ACC zkb 078 Circuit Schematic Outline drawing PCB drawing and more User I O CNB1 User I O CN4 Solder pad for SMA Connector 80 pin Male Connector User I O CN3 User I O CNA1 ...

Страница 6: ...KIT User s Manual Ver 1 0 Apr 06 2010 HuMANDATA LTD Address 1 2 10 2F Nakahozumi Ibaraki Osaka Japan ZIP 567 0034 Tel 81 0 72 620 2002 Japanese Fax 81 0 72 620 2003 Japanese English URL http www hdl co jp en Global http www hdl co jp Japan ...

Отзывы: