NOTICE

Analytical instruments for in vitro diagnostic application involve the handling of human samples and controls

which should be considered at least potentially infectious. Therefore every part and accessory of the respective

instrument which may have come into contact with such samples must equally be considered as potentially

infectious.

BIOHAZARD

The „BIOHAZARD“ warning label must be affixed to instrument prior to first use with biological material !

Servicing Note:

Before doing any servicing on the instrument it is very important to thoroughly disinfect all possibly contaminated

parts. Before the instrument is removed from the laboratory for disposal or servicing, it must be decontaminated.

Decontamination should be performed by authorised well-trained personnel only, observing all necessary safety

precautions. Instruments to be returned have to be accompanied by a decontamination certificate completed by

the responsible laboratory manager. If a decontamination certificate is not supplied, the returning laboratory will

be responsible for charges resulting from non-acceptance of the instrument by the servicing centre, or from

authority’s interventions.

HUMAN

Gesellschaft für Biochemica und Diagnostica mbH
|   Max-Planck-Ring 21 · 65205 Wiesbaden · Germany
|   Tel.: +49 61 22/99 88-0 · Fax: +49 61 22/99 88-100
|   e-Mail: [email protected] · 

www.human.de

Содержание HUMAX 4K

Страница 1: ...Gtl w 3J User Manual Cat No 15210 100...

Страница 2: ...i Qduhrhnm Khrs ne sgd L mt k No DATE Rev REVISION DESCRIPTION 1 01 2007 01 First edition...

Страница 3: ...ii...

Страница 4: ...llation of this product This warranty does not apply to damages incurred in shipment of goods Any damage so incurred shall be reported to the freight carrier for settlement or claim 3 INTENDED USE OF...

Страница 5: ...at least potentially infectious Before doing any servicing on the instrument it is very important to thoroughly disinfect all possibly contaminated parts Before the instrument is removed from the labo...

Страница 6: ...sibly contaminated parts Before the instrument is removed from the laboratory for disposal or servicing it must be decontaminated Decontamination should be performed by authorised well trained personn...

Страница 7: ...b...

Страница 8: ...lock System 4 5 Instructions for Use 5 5 1 Schematic Drawing 5 5 2 Controls and Indicators 6 5 3 Preparing The Run 6 5 4 Programming 7 5 5 Program Recall 7 5 6 Starting Running and End Of Run 7 5 7 Er...

Страница 9: ...does not allow the centrifuge to operate or the rotor to spin if the lid is not closed The lid locking system allows the lid to be opened when the program ends by pressing a single key There are audib...

Страница 10: ...balance The central hole of the rotor and the motor shaft must also be kept clean and dry at all times RDGLQJ Each tube insert must be the same weight as the one diametrically opposite for balancing C...

Страница 11: ...d set step 10 rpm Timer set range 1 99 minutes and hold position Timer set step 1 minute Motor Induction Motor Supply Values 230 V 50 Hz Power Consumption 350 W External Dimensions WxDxH mm 274 x 355...

Страница 12: ...5 10 XPDQ X0D User Manual 5 Instructions for Use 6FKHPDWLF UDZLQJ Figure 1...

Страница 13: ...o set the speed and time during programming and to check the RCF value during the operation 5 Pulse Key Causes the motor to increase to the maximum speed The motor will continue to spin at that speed...

Страница 14: ...otor stops spinning When the program is completed END is shown on the speed display 1 and the warning beep sounds to indicate to the user that program has ended The warning beep will continue to sound...

Страница 15: ...ere hazardous substances including radioactive chemicals are frequently found Always use the appropriate decontamination procedures where the rotor is exposed to these chemicals Examples of commonly u...

Страница 16: ...DLO No daily cleaning is required except in the case of accidental glass breakage or a large amount of spillage in the bowl HHNO Clean the bowl and the accessories with a cotton wool pad dipped in 70...

Страница 17: ...10 10 8 Electrical Circuit Diagram...

Страница 18: ...HUMAN Gesellschaft f r Biochemica und Diagnostica mbH Max Planck Ring 21 65205 Wiesbaden Germany Tel 49 61 22 99 88 0 Fax 49 61 22 99 88 100 e Mail human human de www human de 01 2007 01...

Отзывы: