What’s not working 
properly? 

What are the symptoms?  Here’s what to do: 

 

Remote Control 
(error code 90) 

Screen is blank or 
display is abnormal. 

1)

 

Make sure the remote is 
securely plugged into the chair. 

2)

 

Replace the remote. 
IMPORTANT:  This requires a 
software update; send the 
appropriate software update kit 
with the remote. 

3)

 

If the problem remains, replace 
the main PCB. IMPORTANT:  
This requires a software update; 
send the appropriate software 
update kit with the PCB. 

 

Text displays normally 
but the selected function 
doesn’t work. 

Refer to that function elsewhere in 
this table. 

Содержание HT-Ascent 4

Страница 1: ......

Страница 2: ...ay shut down to protect the chair from overheating This is a safety feature 2 Power off the chair wait a few seconds then power it back on 3 Verify that the power switch lights which confirms that the chair is receiving power If the switch does not light see Power for further instructions 4 Select the issue that best describes the problem Remote Control Air Massage Foot Calf Robotic Massage Backre...

Страница 3: ...to the chair 2 Replace the remote IMPORTANT This requires a software update send the appropriate software update kit with the remote 3 If the problem remains replace the main PCB IMPORTANT This requires a software update send the appropriate software update kit with the PCB Text displays normally but the selected function doesn t work Refer to that function elsewhere in this table ...

Страница 4: ...ble and data cable 2 If the problem remains replace the main PCB IMPORTANT This requires a software update send the appropriate software update kit with the PCB If the serial number is below J3215 also send a remote Air Massage No air massage is working backrest seat arms or foot calf Replace the air pump The shoulder massage is 1 If the left side shoulder massage is not working replace air valve ...

Страница 5: ...ve kit 1 The front arm massage is not working 1 If the left side front arm massage is not working replace air valve kit 2 and 3 2 If the right side front arm massage is working replace air valve kit 2 The rear arm massage is not working 1 If the left side rear arm massage is not working replace air valve kit 2 and 3 2 If the right side rear arm massage is working replace air ...

Страница 6: ... working either side Replace air valve kit 1 The seat massage is not working Replace air valve kit 2 and 3 The hip massage is not working 1 If the left side hip massage is not working replace air valve kit 2 2 If the right side hip massage is not working replace air valve kit 2 and 3 The foot air massage is Replace air valve kit 2 ...

Страница 7: ...B IMPORTANT This requires a software update send the appropriate software update kit with the PCB If the serial number is below J3215 also send a remote Foot Calf Robotic Massage error code E6 E7 E8 The foot calf massager rollers are not massaging 1 Replace the foot calf massager 2 If the problem remains replace the main PCB IMPORTANT This requires a software update send the appropriate software u...

Страница 8: ...rest actuator 2 If the problem remains replace the main PCB IMPORTANT This requires a software update send the appropriate software update kit with the PCB If the serial number is below J3215 also send a remote The foot calf massager will not extend or retract error code E3 1 Raise or lower the foot calf massager slightly this resets the internal controls 2 If the problem remains replace the foot ...

Страница 9: ...t are the symptoms Here s what to do 3 If the problem remains replace the main PCB IMPORTANT This requires a software update send the appropriate software update kit with the PCB If the serial number is below J3215 also send a remote ...

Страница 10: ... cord is damaged replace it 3 Check the wall outlet Plug a known working device into the outlet If the device doesn t work the outlet is likely defective Plug the chair into a working outlet 3 Replace the main PCB IMPORTANT This requires a software update send the appropriate software update kit with the PCB If the serial number is below J3215 also send a remote 5 23 2016 ...