7528%/(6+227,1*
en010008.ss550s.FM
45
7URXEOHVKRRWLQJ
:DUQLQJ
6\PSWRP
3UREDEOHFDXVH
$FWLRQ
The saw motor is rotating
backwards when the grapple
open function is activated.
Check valve in saw motor “T” line is
leaking or missing
Clean or replace the check valve
Frequent problems with leaking
saw motor shaft seal.
Malfunction of the check valve in the
saw motor manifold.
Clean or replace the check valve.
The inner leakage of the saw motor is
too high in comparison with the
capacity of the accumulator in the case
drain circuit.
Replace the saw motor.
The accumulator in the saw motor case
drain circuit is damaged
Replace the accumulator
Saw bar feed out malfunction
Feed out pressure is too low
Adjust the feed out pressure
Damaged feed out cylinder seals,
which will cause the air tank to fill up
with oil.
Drain the air tank from oil and replace the
seals.
Lubrication Malfunction
(For more information on this
issue see Troubleshooting
SuperCut)
Membrane in filler cap is damaged
Replace the membrane.
Difficulties to adjust the tension
pressure
Accumulator in the saw motor case
drain circuit is damaged
Replace the accumulator
Malfunction of the check valve in the
saw motor manifold for the saw bar
retraction funtion.
Clean or replace the check valve