CSB 229
5
ACTION REQUIRED
Install the PES 5000 version 3 indoor unit where so indicated by installation work order consistent with the following
information. Make the IFL connections according to the installation described in this CSB
IFL cable installation
As shown in figure 2, the PES 5000 version 3 indoor unit has an F-type connector for the IFL cable. The present PES
5000 Outdoor Units have an N-type connector. Use the adapter(s) included in the indoor unit packaging box to connect
the indoor unit to the IFL cable.
Port Level Conversion Module (PLC) Installation
A PLC is an optional daughter card that provides a specific interface function for ports 3 and 4 or provides the voice
function for voice port. As listed in table 8, the EIA-232 PLC part number 3000066-0002 is approved and is directly
applicable for PES 5000 version 3 at this time.
Note: Do not install PLC part number 3000066-0001 in PES 5000 version 3. It does not have proper ESD protection
in PES 5000 version 3, but does have ESD protection provided by the host circuit card in PES 5000 versions 2 and earlier.
Table 3. PLC Types and PES 5000 Version
PLC Type, Function
HNS Part
Number
Applicable for
PES 5000
Versions 1, 1A and 2
Applicable for
PES 5000
Version 3
EIA-232, provides two EIA-232 ports
3000066-0002
Yes
Yes
EIA-232, provides two EIA-232 ports
3000066-0001
Yes
No
RS-422/485, provides two RS-422/485
ports
1012327-0001
Yes
Yes
V.35 PLC, provides two V.35 ports
1013130-0001
Yes
Yes
Modem Backup, “Fail Safe PLC”
Provides one RS-232 port A and one
metallically connected backup port B for
use during space link failure.
3000206-0001
Yes
No
Voice Port Kit for PES 5000 versions 1,
1A and 2
3002693-0001
Yes
No
Voice Port Kit – VDC2 Multi-Chassis
(This kit is not available currently.)
3002930-0001
Yes
Yes, TBD
Perform the steps listed below to install a data PLC inside PES 5000 version 3.
STEP 1.
Remove power from the PES 5000 version 3 indoor unit by unplugging the power cord.
STEP 2.
Observe Electro-Static Discharge (ESD) precautions. Ground yourself, the PES 5000 version 3 chassis, your
tools and the bag containing the PLC.
STEP 3.
Remove the cover/front panel assembly, as shown in figure 5 & 6 on page 6 & 7.
A)
Remove the screw from the indentation in the bottom of the unit.
B)
Place the unit on a flat sturdy surface. Apply some downward pressure on the top of the unit near the
sides about mid-way between the front and the rear in order to disengage the retaining flanges.
C)
While applying downward pressure, carefully and slowly slide cover/front panel assembly
approximately two inches toward the front of the unit. CAUTION: Do not pull too hard on the chassis
Содержание PES 5000