background image

BASSBASE 400 - MANUAL

4.0 

SERVICE AND PREVENTIVE

MAINTENANCE

The BASSBASE 400 will not require service of any type for

many years. Tube fatigue is normal after several thousand

operating hours and becomes apparent through treble loss or

increased microphonics (audible as a ringing noise
reproduced by the tweeter).

Use a soft, slightly damp cloth to clean the BASSBASE 400’s
metal parts. Use a brush to clean the flock covering (combo

version).
Avoid exposure to mechanical shocks, extreme heat, dust
and moisture.

5.0 POSSIBLE ERROR SOURCES/

TROUBLE-SHOOTING

E1)

The BASSBASE is not getting any power:

-

 Check the mains cable to see if it is connected properly.

- The mains fuse is defective. Replace the fuse with another

identical fuse. If this fuse also blows, consult your Hughes &
Kettner dealer.

E2)

The BASSBASE is connected properly, but no 

sound is

audible.

-

 The MUTE function is activated. Press the MUTE button!

- One or several GAIN and MASTER controls are turned all
the way down. Dial in a higher setting.
- The FX-MIX control is turned all the way to WET but you
have not connected a processor to the FX loop. Turn the FX-
MIX knob to DRY.
- One of the circuit breakers has tripped. Locate and
eliminate the defect (e.g. inadequate ventilation, defective
speaker cable)
- One of the internal fuses is blown (e.g. caused by a
permanent short in the speaker output jack). Locate and
eliminate the defect and have the fuse changed by a
qualified service technician (make sure the replacement fuse

bears the proper rating).

E3)
Using a footswitch, you are unable to turn off the

VARIMETRIC EQ or the FX LOOP:

-

 The EQ or FX LOOP front panel selector switches were

inadvertently left in the ON position. Press the appropriate

selector switch to disengage the front panel control.

E4)

The 

sound is thin and muddy when the 

FX 

processor is

active.
-

 The signal processor is causing phase shifting that is being

added to the original signal in the parallel loop. Turn the

FX-MIX control all the way to the right (WET) to avoid phase

cancellations.

E5)

The red CLIP LED keeps illuminating.

-

 The BASSBASE 400’s input is overloaded. Press the - 10 dB

button or turn your instrument’s volume pot down.
- The BASSBASE 400 preamp is overloaded. Reduce the
GAIN.
- The BASSBASE 400 FX LOOP is overloaded. Briefly
disconnect the FX processor from the loop. If the CLIP LED
no longer illuminates, you must reduce the processor’s
output level.

E6)

When accessed, the DI OUT jack causes annoying hum.

-

 The connected device’s input circuit is unbalanced and an

electrical or magnetic field is causing interference. Use a

balanced input or situate the cables to reduce interference to

a minimum.
- The grounding of the connected devices are causing a
ground loop. Do not sever the ground of the connected
devices under any circumstances! Activate the GROUND

LIFT SWITCH. If this doesn’t eliminate the noise, you must

ensure the connection is galvanically separated by routing
the signal through a DI box.

10

Содержание Bass Base 400

Страница 1: ...BEDIENUNGSANLEITUNG l l 400 WATTS BASSAMPLlFlER MANUAL B A S S T E C H N O L O G Y ...

Страница 2: ...SATURATION LED Indicates the preamp is in tube overdrive mode MUTE Switches all of the BASSBASE 400 s outputs except for the TUNER OUT off Use this button for breaks between sets switching instruments or when tuning The RED MUTE LED will illuminate to indicate the amp is muted DI OUT Use this jack to send signals to a mixing console or additional power amp INPUT Connect your bass to this jack CAIN...

Страница 3: ...ort circuit in the SPEAKER OUTS or direct current in the output will trigger the circuit breaker TEMP LED Indicates that thermal overload overheating is the reason why the protective circuit has activated e g when the ribbed ventilation duct is obstructed FREQ KHZ LEVEL dB FREQ HZ CUT dB FREQ Use this control to adjust the notch filter s center frequency within a range of 30 to 500 Hz s control ad...

Страница 4: ...rocessors expecting an instrument level signal such as stomp boxes C MAINS SOCKET Connect the included power cable Euro norm to this socket The fuse bracket is integrated in the socket make certain you use specified replacement fuses only SEND Connect this jack to the FX processor s INPUT jack SPEAKER OUTPUTS Output jacks for connecting external bass speaker cabinets these jacks are wired in paral...

Страница 5: ...perly turn your instrument s volume all the way up and spank the plank hard by slapping or really digging in with your pick For the ideal setting the RED CLIP LED will illuminate briefly on peaks only If the signal is too hot press the 10 dB button to damp it NOTE The RED CLIP LED illuminates to indicate distortion in the BASSBASE 400 preamp caused by a saturated input or incorrect FX processor le...

Страница 6: ...can now use the LEVEL control to amplify attenuate selected frequencies as desired Use the same procedure to tune the upper mid frequencies via the FREQ KHZ and LEVEL controls LEVEL to maximum tune FREQ KHZ then adjust LEVEL to amplify attenuate the chosen frequencies This frequency diagram depicts the effects of the VARIMETRIC EQ on the lower midrange As clearly illustrated the boost of a complet...

Страница 7: ...CH Adjust the FX loop s level to your FX processor s input level Press the 10 db button for effects devices that are designed for instrument levels If the button is not pushed in the signal remains at standard line level for 19 rackmounted processors Adjust the blend between the original and processed signal via the FX MIX pot located on the front panel Towards DRY more original signal towards WET...

Страница 8: ...ate the defect and have the fuse changed by a qualified service technician make sure the replacement fuse bears the proper rating E3 Using a footswitch you are unable to turn off the VARIMETRIC EQ or the FX LOOP The EQ or FX LOOP front panel selector switches were inadvertently left in the ON position Press the appropriate selector switch to disengage the front panel control E4 The sound is thin a...

Страница 9: ...SIONS Combo LxHxD Weight Head LxHxD Weight ECC83 12AX7A 50 Hz 15 10 dB active 2 20 kHz 16 12 dB active 80 l000 Hz 12 16 dB active 500Hz 15 kHz 12 16 dB active 30 500 Hz 16dB 0 dB 10 dB 470 kOhms switchable 0 dB 10 d B 47 kOhms switchable 0 db 10 dB 220 Ohms 0 dB 220 Ohms 10 dB 200 Ohms balanced 10 dB O dB 4 7 kOhms 396 Watts RMS into 4 Ohms 1 THD 260 Watts RMS into 8 Ohms 1 THD 612 Watts Dynaclip ...