i) Increase the engine speed to the desired working level, using the hand throttle lever at
the side of unit. Use of the throttle will directly affect output water volume and
pressure.
DURING WORK
:
a)
Do not leave the COMMANDO 500
idling as re-circulating water heats up rapidly
and will eventually boil causing severe damage to the pump.
b)
Should any vibration, fluctuation of pressure or any other abnormal symptoms occur
during operation, this should be investigated immediately.
Likely causes include:-
i)
A lack of water entering the unit causing air to be drawn into the pump.
ii)
A blockage of the main inlet filter causing water starvation at the pump.
iii)
The inlet water valve between tanks and pump not fully open.
iv)
Leaking seals or damaged valves etc.
AFTER WORK
a)
To stop the
COMMANDO 500 turn the engine speed control fully anticlockwise and
the engine will stop. Alternatively the engine stop button may be pressed and held
until the engine stops. |Turn the starter key to the ‘O’ position.