TROUBLESHOOTING
STRUCTURE SKETCH
PARTS LIST
PROBLEM
CAUSE
SOLUTION
The motor fails to start
after being powered on.
• The power cable has come off
• The battery needs recharging
• The power switch has been damaged
• Dismantle the base to connect
the cables soundly.
• Charging
• Replace the switch
Abnormal sound heard
in the motor.
• The fastening screws for the pump
are loose
Tighten the screws.
Leakage occurs to the
bottom of the base.
• The inlet and outlet tubes of pump
break or are loose at the connection
• Dismantle the base and tighten
the tube clamps.
Poor atomization.
• The spraying hole was clogged
• Spraying hole and o-ring worn
• Seal is upside down
• Filter screen was clogged
• Leakage occurred to tubes at joints
• Battery short of power
• Air remained in the pump
• Remove foreign matter
• Replace o-rings
• Correct by reversing
• Clean with clear water
• Tighten screws
• Alarm maybe out of order, replace
it, charge.
• Remove the nozzle or extension
rod to discharge the air
Conical mist o-ring