A noncombustible hearth pad
must cover combustible flooring
underneath, as well as 9” in front of
the heater and 6” to the side of the
heater
1. Install the hearth pad.
2. Lock the fireplace damper in the
open position.
3. Install a positive flue connector at
the fireplace damper.
4. Connect a tee or 90° degree elbow
to the exhaust pipe.
5. This fireplace insert must be
installed with a continuous
chimney liner of 3 or 4” diameter
extending from the fireplace
insert to the top of the chimney.
The liner must conform to type 3
requirements of CAN/ULC S635.
6. (Recommended) Install fresh air
intake either through the back
of the fireplace or through the
positive flue connector.
When installing the insert into a
masonry fireplace DO NOT remove any bricks or masonry, with the following exception; masonry or
steel, including the damper plate, may be removed from the smoke shelf and adjacent damper frame if
necessary to accommodate a chimney liner. Provided that their removal will not weaken the structure
of the fireplace and chimney, and will not reduce protection for combustible materials to less than that
required by the national building code.
When installing the fireplace insert into a zero clearance fireplace,
DO NOT
cut or modify any factory
firebox parts. If the fireplace insert does not fit into a zero clearance fireplace we recommend you use
an ENVIRO freestanding model and install as a hearth mounted unit.
Install a 3” (76 mm) flex pipe from
the stove to the top of the chimney (see “
i
nstallation
- h
earth
m
ount
i
nstallation
- f
reestanding
”).
Installation
m
aSonRy
f
iRePLace
i
nSeRt
i
nStaLLation
- f
iRePLace
i
nSeRt
:
The Fireplace insert model requires a surround faceplate and a pedestal. When installing this unit, ensure
that the pedestal is removed from the inside of the hopper and installed on the bottom of the unit (Refer
to
i
nstallation
- i
nstallation
of
p
edestal
and
l
eveling
l
egs
- f
ireplace
i
nsert
).
Adjust hopper height (see
i
nstallation
- i
nstalling
h
opper
c
over
and
a
djusting
h
opper
h
eight
- f
ireplace
i
nsert
)
and assemble surround panel (see Installation -
i
nstallation
and
r
emoval
of
c
ontrol
p
anel
in
t
he
s
urround
p
anel
- f
ireplace
i
nsert
and Installation -
a
ssembly
and
i
nstallation
of
i
nsert
s
urround
p
anels
- f
ireplace
i
nsert
)
before starting installation.
Figure 21: Installation of Fireplace Insert.
18
Floor
Protection
Combustible Floor
Masonry Fireplace
Min 9"
Rain Cap
Steel Plate or Flashing
Flexible or Rigid 6"
Stainless Steel Liner
Mantel
Minimum 8" (20 cm)
from top of stove
Surround Panel
Fresh-air intake
Clean-out tee
If holes already exist
fresh-air intake can
be taken through the
back of the fireplace
or through the ash
dump.
Flexible stainless
steel pipe connection
Damper Removed
or Fastened Open