Hudson River Stove Works DAVENPORT Скачать руководство пользователя страница 1

50-2322

PELLET STOVE

DAVENPORT

THIS MANUAL IS PRINTED ON RECYCLED PAPER.

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

OWNER’S MANUAL

Freestanding and Fireplace Insert

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION 

AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO 

FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY 

DAMAGE, BODILY INJURY OR EVEN DEATH.

Contact your building or fire officials about restrictions and installation inspection 

requirements in your area. 

16621

Содержание DAVENPORT

Страница 1: ...estanding and Fireplace Insert PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY...

Страница 2: ...g recommended 14 through concrete wall with vertical rise installation freestanding 14 inside vertical installations freestanding 15 outside vertical installations freestanding 16 hearth mount install...

Страница 3: ...meter 1 long maximum Ash Content 1 maximum Premium grade 3 maximum Standard grade Moisture Content 8 maximum Heat Content approximately 8200 Btu per pound minimum ASH The ash content of the fuel and o...

Страница 4: ...e that the structural integrity of the home is maintained and all construction meets local building codes Minor soot or creosote may accumulate when the stove is operated under incorrect conditions su...

Страница 5: ...freshen up a fire in the heater Keep all such liquids well away from the heater while it is in use SMOKE DETECTOR Smoke detectors should be installed and maintained in the structure when installing an...

Страница 6: ...n Fuel type Residential Pellet Heater 6mm dia Wood Pellets Voltage Current Max Power 110 120 V 3 3 Amps 400 Watts Frequency Hopper Capacity FS FPI Consumption on Low 60 Hz 60 lbs 40 lbs 1 5 lb hr Test...

Страница 7: ...ross sectional area An interior vent can be used with approved pipe passing through the ceiling and roof 5 Locate the stove in a large and open room that is centrally located in the house This will op...

Страница 8: ...ort on Floor Protection Installation Clearances to Combustibles Freestanding These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing routine cleanin...

Страница 9: ...tory Secure outside air connections directly to fresh air intake pipe and secure with three 3 screws evenly spaced Installation 9 Clearances to Combustibles Fireplace Insert The fireplace insert must...

Страница 10: ...1 for allowable exterior vent termination locations Table 2 Use in conjunction with Figure 13 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above...

Страница 11: ...king during power failures When connecting to an outside fresh air source do not use plastic or combustible pipe A 2 minimum 51 mm ID inside diameter steel aluminum or copper pipe should be used It is...

Страница 12: ...the appliance 15 37 5 cm away from the wall If the stove is to be set on a hearth pad set the unit on it 4 Locate the center of the exhaust pipe on the stove Extend that line to the wall Once you have...

Страница 13: ...lding If necessary bring another length of pipe PL type to the outside of the home to connect to the first section Do not forget to place high temperature silicone around the pipe that passes through...

Страница 14: ...e recommended installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove The termination must be 12 inches 30 cm from the outside wall and 12 inches 30 cm a...

Страница 15: ...t Over 15ft 4 Vent 2 Place the unit on the hearth pad if installed on a carpeted surface and space the unit in a manner so when the pellet vent is installed vertically it will be 3 76 mm away from a c...

Страница 16: ...then finish it by performing the following refer to Figure 23 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that you install support bracke...

Страница 17: ...Over View Floor Protection Combustible Floor Masonry Fireplace Min 9 Mantel Minimum 8 20 cm from top of stove NOTE Hopper lid will not open fully with less than 13 5 Damper Removed or Fastened Open Cl...

Страница 18: ...parts If the fireplace insert does not fit into a zero clearance fireplace we recommend you use an ENVIRO freestanding model and install as a hearth mounted unit Install a 3 76 mm flex pipe from the...

Страница 19: ...ry fireplace positive flue installation into the fireplace and prevent air from the fireplace from entering the chimney which will affect proper drafting of appliance A qualified installer should eval...

Страница 20: ...ls Required None 1 Attach the control panel to the surround panel see Installation of Control Panel in the Surround Panel Fireplace Insert 2 Slip the surround panel down behind the unit as shown in Fi...

Страница 21: ...switch blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down The vacuum pressure inside the firebox will increase as the combustion exhaust blower inc...

Страница 22: ...tons 6 ON OFF BUTTON Used to turn the unit ON and OFF 7 HEAT LEVEL ADJUSTMENT BUTTONS When pressed will change the heat level setting of the unit up or down 8 HEAT OUTPUT INDICATOR Shows the present h...

Страница 23: ...F HIGH LOW MANUAL AUGER C 11625 MODE 1 2 3 4 5 6 8 7 9 the thermostat contacts close within the 30 minutes the HEAT LEVEL will return to the previous MANUAL setting If the thermostat contacts remain o...

Страница 24: ...Figure 8 The combustion exhaust blower is a variable speed blower controlled by the heat output button This blower will decrease the vacuum pressure inside the stove when the heat output level is turn...

Страница 25: ...the auger to jam and may result in pellets burning in the drop tube and hopper Using the metal scraper tool provided remove material that has accumulated or is clogging the liner s holes Then dispose...

Страница 26: ...airtight assembly ASH PAN weekly The ash pan is located under the burner Dump the ashes into a metal container stored away from combustibles Monitor the ash level every week Remember that different pe...

Страница 27: ...ponents Removal POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and...

Страница 28: ...y placed in the burn pot Check the Heat Level Indicator If the 2 light is flashing see the 2 light is flashing Check the fuse on the circuit board If the unit still does not start contact your local s...

Страница 29: ...is installed Check the operation by opening a window does this solve the problem If it does install fresh air intake to unit or room Venting system may require vertical section to move termination int...

Страница 30: ...ight orange in color If not replace the ignitor 9 Control settings Heat Level has no effect on the fire NOTE If the system light is flashing the Control Board has complete control of the unit When the...

Страница 31: ...Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Grey Purple Purple Blue 115V Black Black Black Black Blue Vacuum Switch Combustion Blower Power Cord Ground Ignitor Exhaust Temperature Sensor...

Страница 32: ...4 5 6 7 8 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 3 17 22 23 29 30 49 50 51 1 2 9 10 12 15 16 18 21 24 31 48 54 PARTS DIAGRAM FS 32...

Страница 33: ...33 PARTS DIAGRAM FPI 11 13 14 15 16 20 21 24 28 30 48 50 52 4 5 6 7 8 9 32 33 34 35 36 38 39 40 41 42 43 44 47 1 2 3 19 22 23 29 31 45 46 49 51 54...

Страница 34: ...34 PARTS DIAGRAM OPTIONS 27 53 25 26 53 55...

Страница 35: ...RETURNED 11 50 2324 DAVENPORT FPI HOPPER COVER OLD SERIALIZED PART MUST BE RETURNED 12 50 2325 DAVENPORT FS TOP 13 50 2326 DAVENPORT FPI HOPPER LID 14 50 2327 DAVENPORT FPI TOP 15 50 2328 DAVENPORT DO...

Страница 36: ...T CIRCULAR 43 EF 013 TEMPERATURE SENSOR 160F 44 EF 016 HIGH LIMIT TEMP SENSOR 200F MANUAL RESET 45 EF 017 VACUUM SWITCH 46 EF 018 SILICONE HOSE RED 47 EF 019 ALUMINUM HOSE BARB 48 EF 030 DOOR HANDLE W...

Страница 37: ...ver damage or breakage due to misuse improper handling or modifications All Claims under this warranty must be made through the dealer in which the stove was originally purchased from If an inspection...

Страница 38: ...________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _________________________________...

Отзывы: