background image

Americas

Alcoa Fastening Systems

Aerospace Products
Tucson Operations

3724 East Columbia
Tucson, AZ 85714
800‐234‐4825
520‐747‐9898
FAX: 520‐748‐2142

Alcoa Fastening Systems

Aerospace Products
Carson Operations

PO Box 5268
900 Watson Center Rd.
Carson, CA 90749
800‐421‐1459
310‐830‐8200
FAX: 310‐830‐1436

Alcoa Fastening Systems

Industrial Products
Waco Operations

PO Box 8117
8001 Imperial Drive
Waco, TX 76714‐8117
800‐388‐4825
254‐776‐2000
FAX: 254‐751‐5259

Alcoa Fastening Systems

Industrial Products
Kingston Operations

1 Corporate Drive
Kingston, NY 12401
800‐278‐4825
845‐331‐7300
FAX: 845‐334‐7333

Alcoa Fastening Systems

Industrial Products
Latin America Operations

Avenida Parque Lira. 79‐402
Tacubaya Mexico, D.F.
C.P. 11850
FAX: 525‐515‐1776
TELEX: 1173530 LUKSME

Far East

Alcoa Fastening Systems

Industrial Products
Australia Operations

14 Viewtech Place
Rowville, Victoria 
Australia  3178
03‐764‐5500
Toll Free: 008‐335‐030
FAX: 03‐764‐5510

Europe

Alcoa Fastening Systems

Industrial Products
United Kingdom Operations

Unit C, Stafford Park 7
Telford, Shropshire
England TF3 3BQ
01952‐290011
FAX: 0952‐290459

Alcoa Fastening Systems

Aerospace Products
France Operations

Clos D’Asseville
BP4
95450 Us Par Vigny
France
33‐1‐30‐27‐9500
FAX: 33‐1‐34‐66‐0600

A Global Organization

Alcoa Fastening Systems (AFS) maintains
company offices throughout the United States
and Canada, with subsidiary offices in many
other countries. Authorized  AFS distributors
are also located in many of the world’s 

Industrial and Aerospace centers, where they
provide a ready source of AFS fasteners,
installation tools, tool parts, and application
assistance.

For The Long Haul, The Future of Fastening
Technology, The Future of Assembly Technology,
The Future of Tooling Technology, and Tools of
Productivity are service marks of Huck
International. Huck provides technical assistance
regarding the use and application of Huck fasten‐
ers and tooling.

NOTICE: The information contained in this publi‐
cation is only for general guidance with regard to
properties of the products shown and/or the

means for selecting such products, and is not
intended to create any warranty, express,
implied, or statutory; all warranties are contained
only in Huck’s written quotations, acknowledge‐
ments, and/or purchase orders. It is recommend‐
ed that the user secure specific, up‐to‐date data
and information regarding each application
and/or use of such products.

HWB898    

1003‐5M

© 2003 Alcoa Fastening Systems

1 Corporate Drive, Kingston, NY 12401  • Tel: 800‐431‐3091 • Fax: 845‐334‐7333 •  www.alcoafasteningsystems.com

Certified to

ISO 14001:2004

Industrial

Products

Certified to

ISO 9001:2008

Industrial

Products

One Great Connection

SM

Alcoa Fastening Systems world-wide locations:

For the Long Haul

Содержание Alcoa POWERIG 968

Страница 1: ...July 15 2014 HK1126 INSTRUCTION MANUAL M MODELS ODELS 968 968D 968 968D POWERIG HYDRAULIC UNIT 968 968D...

Страница 2: ...nts for fluid power systems their com ponents Pneumatics EN ISO 13849 1 2008 Safety related parts of control systems Part 1 EN ISO 13849 2 2008 Safety related parts of control systems Part 2 EN ISO 14...

Страница 3: ...ems 3 C CONTENTS ONTENTS SAFETY 4 PRINCIPLE OF OPERATION 5 DESCRIPTION 5 SPECIFICATIONS 6 OPTIONAL EQUIPMENT 6 ADDITIONAL SAFETY PRECAUTIONS 7 OPERATING INSTRUCTIONS 7 TOOL TO POWERIG SETUP 8 MAINTENA...

Страница 4: ...ten er ejecting may occur 17 Where applicable always clear spent pintail out of nose assembly before installing the next fastener 18 There is possibility of forcible ejection of pintails or spent man...

Страница 5: ...kPa and return pressure valve is set at 2700 3300 psi 15200 16500 kPa Pressures are adjustable to match Huck installa tion tool being used See applicable installation tool manual Hydraulic fluid is st...

Страница 6: ...tools shall be fire resistant fluid approved under schedule 30 of the US Bureau of Mines Department of Interior and shall retain its operating characteristics at the most extreme temperatures to whic...

Страница 7: ...in place on Filler Breather Cap before installing 2 Fill reservoir with hydraulic fluid approximately 2 quarts 1 9 liters until the fluid level is within one inch of the top of the reservoir 3 Use a...

Страница 8: ...G Only use compatible equip ment with this Powerig WARNING To prevent tripping hazard suspend tools and route hoses off of floors WARNINGS Read full manual before using tool A half hour training sessi...

Страница 9: ...TOR If the pump is operated on a continuous duty cycle or at maximum speed for an exteded period an automatic air line oiler is recommended Install the oiler in the air inlet line as close to the pump...

Страница 10: ...41 1 3 Motor Base Gasket 130142 2 4 Air Motor 130143 1 5 Motor Shaft Coupling 130145 1 6 Drain 130146 1 7 Plug Fitting 508485 1 8 Nut 506457 1 9 O Ring 508486 1 10 Muffler 508487 1 11 Sight Gauge 5084...

Страница 11: ...3 1 26 Straight Fitting 508494 1 27 Male Fitting 508495 1 28 Straight Fitting 508496 1 29 Tee Fitting 508497 1 30 Plug Fitting 508498 1 31 Straight Fitting 508499 1 32 Quick Coupler 508500 1 33 Pull H...

Страница 12: ...e Low hydraulic fluid level in reservoir f Hydraulic fluid viscosity too heavy to pick up prime g Clogged suction screen h Defective hydraulic pump i Defective spool valve assembly j Installation tool...

Страница 13: ...day warranty period for tooling other items nonstandard or custom products described above and Huck shall inspect products for which such claim is made TOOLING PART S AND OTHER ITEMS NOT MANU FACTURED...

Страница 14: ...nization Alcoa Fastening Systems AFS maintains company offices throughout the United States and Canada with subsidiary offices in many other countries Authorized AFS distributors are also located in m...

Отзывы: